95 research outputs found

    TCT-3 Early results of multicenter, prospective trial of TEVAR for blunt thoracic aortic injury (RESCUE Trial)

    Get PDF

    Results of a multicenter, prospective trial of thoracic endovascular aortic repair for blunt thoracic aortic injury (RESCUE trial)

    Get PDF
    ObjectiveTo evaluate the early outcomes of patients undergoing thoracic endovascular aortic repair for blunt thoracic aortic injuries.MethodsA prospective, nonrandomized, multicenter trial using the Medtronic Valiant Captivia stent graft was conducted at 20 sites in North America. Fifty patients with blunt thoracic aortic injuries were enrolled between April 2010 and January 2012 and will be followed for 5 years. The injuries were classified into categories (grades I-IV) based on severity: intimal tear, intramural hematoma, pseudoaneurysm, or rupture. The primary end point was 30-day all-cause mortality. Secondary end points were adverse events occurring within 30 days that were related to the procedure, device or aorta, and aortic-related mortality. Technical success was measured as successful device delivery and deployment.ResultsSeventy-six percent (38/50) of patients were male with mean age of 41 ± 17 years. Fifty-one Medtronic Valiant Captivia thoracic stent grafts and a single Talent thoracic stent graft were implanted within a median of 1.0 days following injury (mean, 1.8 ± 4.0 days). Seventy percent (35/50) of aortic injuries were grade III or higher, including one patient with free rupture. Mean injury severity score was 38 ± 14. Fifty-four percent of stent grafts were ≤26 mm (28/52). The left subclavian artery was completely covered in 40% of patients (20/50) and partially covered in 18% of patients (9/50). Four patients underwent subclavian artery revascularization: one at the time of the endograft procedure and three others after developing arm ischemia after the initial endograft procedure. Cerebral spinal fluid was drained in two patients. The median procedure time was 91 minutes, and median hospital stay was 12 days. There was 100% successful device delivery and deployment. Four (8%) patients died within 30 days. Nonfatal adverse events within 30 days that were related to the procedure, device, or aorta were experienced by 12% (6/50) of patients. No nonfatal adverse events related to the device were reported; a single death was conservatively adjudicated as device-, procedure-, and aorta-related because of insufficient information. No patient developed spinal cord injury, and there were no cerebrovascular accidents. However, one patient had an anoxic brain injury following aortic rupture. No patient underwent conversion to open repair or required an endovascular reintervention.ConclusionsBased on the early outcomes, the Medtronic Valiant Captivia stent graft appears to be a promising treatment modality for blunt thoracic aortic injuries. Long-term follow-up is necessary to substantiate the effectiveness of thoracic endovascular aortic repair in treatment of blunt thoracic aortic injuries

    Evaluation of the trend of temperature changes and cloud water fraction in Iran using time series data from SEVIRI sensor products

    Get PDF
    The purpose of this study is to investigate the trend of temporal and spatial changes in cloud temperature and cloud water fraction in Iran. To achieve this goal, MSG SEVIRI satellite products have been used for the period 2004 to 2017. First, the studied data was set in a regular geographical network with dimensions of 290×380. Then the cloud properties were extracted separately for each month and finally, the time changes of the cloud properties were modeled. To accurately assess the changes in variables, Iran was spatially defined into four separate regions. Based on statistical methods, the trend of time changes was examined through the Mann-Kendall test and Sen’s Slope to reveal the existence of a trend. The results of calculations of indicators showed that water fraction and cloud temperature in Iran, except in May and September, was upward. The highest significant value in the cloud water fraction variable can be seen in June in southern Iran and the lowest in May. Percentage study of the trend showed that the highest significant amount of cloud temperature in June in southern Iran was the lowest in the month. According to the calculations, the lowest amount of cloud water fraction in Iran is located to the north of the country with 25% and the highest amount is located to the west of Iran with 41.6%. Also, concerning high cloud temperatures, southern Iran with 58.3% has the highest amount, and eastern Iran with 25% upward data. The maximum significant percentage of series in the cloud temperature trend in western Iran was 70.83% and the minimum in the south was 45.83%

    Blunt traumatic aortic injury: Initial experience with endovascular repair

    Get PDF
    ObjectivesEndovascular treatment of traumatic aortic injury (TAI) is an alternative to open repair (OR) in patients with blunt trauma. We report our initial experience after integration of endovascular repair using thoracic devices.MethodsA retrospective review of a prospectively collected institutional trauma registry was performed. Between September 2005 and November 2008, 71 patients with TAI presented to our institution. Based on imaging, TAIs were classified into grade 1-4 in severity. These included: grade 1, intimal tear; grade 2, intramural hematoma; grade 3, aortic pseudoaneurysm; and grade 4, free rupture. Initial management included resuscitation, blood pressure control, and treatment of associated injuries. After stabilization, all patients were considered for thoracic endovascular aortic repair (TEVAR) using a thoracic device. If contraindicated, candidates underwent OR. Outcome measures were mortality, stroke, paraplegia, intensive care unit (ICU), and hospital stay.ResultsThe mean age was 39.8 years, with 50 males. The mean injury severity score (ISS) was 42.6. Nineteen (27%) patients with a mean ISS of 60 died shortly after arrival prior to any vascular intervention. Ten (14%) patients with grade 1 injuries were managed medically. The remaining 42 (59%) patients with grade 2 and 3 injuries underwent repair. Median interval between admission and repair was 4.3 days (range, 0-109 days). Fifteen (21%) patients with a mean ISS of 34.4 underwent OR with no mortality, stroke, or paraplegia. Twenty-seven (38%) patients with a mean ISS of 36.7 underwent TEVAR with no mortality or paraplegia. One TEVAR patient suffered a perioperative stroke. Twenty-two patients had a TAG (W.L. Gore & Associates, Flagstaff, Ariz) device. Four patients had a Talent Thoracic (Medtronic Vascular, Santa Rosa, Calif), and 1 patient had an Excluder (W.L. Gore) device. The left subclavian artery was covered in 13 (48%) patients. Patients who underwent TEVAR were older than those who had OR (47.8 vs 31.1 years, P < .006). The aortic diameter proximal to the injury was larger in the TEVAR group (24.4 vs 19.6 mm, P < .0001). There was no difference in the mean ICU or hospital length of stay between the two groups. Mortality correlated with the ISS score (P < .0001). Median follow-up time was 19.4 months (range, 0-27). Only 56% of the TEVAR patients were fully compliant with their surveillance imaging protocol.ConclusionIn this initial experience, the results of TEVAR did not differ from OR. Long-term follow-up is required to determine the effectiveness of this treatment strategy. Adherence to follow-up imaging protocols is challenging in this patient population. Next generation devices will make TEVAR applicable to a wider range of patients

    Prediction of Learning Styles Using Students’ Self-esteem

    Get PDF
    Background & Objective: Learning style is a distinctive, habitual behavior to gain knowledge, skills, or feedback attained through study or experience. The key to engaging students in learning the content is identifying their preferences and learning styles as well as identifying factors influencing these variables. To reach this goal, predictive variables of learning styles should be accurately identified in order to improve the learning environment. The aim of this study was to determine the relationship between learning styles and self-esteem in students of Kerman University of Medical Sciences, Iran. Methods: This descriptive-analytical and cross-sectional study was carried out on 343 students selected through quota sampling method. The data collection tools consisted of a demographic information form, the Kolb Learning Style Inventory (LSI) version 2, and the Rosenberg SelfEsteem Scale (RSES). Data were analyzed using chi-square test, Spearman’s correlation coefficient, linear regression, and logistic regression. Results: The mean (± SD) age of the participants was 21.41 (± 2.96), and 44.3% of students used absorbent learning style. In addition, 60.9% of students had poor self-esteem. No statistically significant association was observed between students’ learning styles and levels of confidence. In addition, the results showed that only gender was a prognostic factor in determining learning styles. Conclusion: The results of this study showed that the students’ self-esteem and learning styles were not correlated; thus, teachers can disregard these factors in their assessment of students' learning styles. Key Words: Learning style, Self-esteem, Medical students, Predictor

    pivotal results for the valiant navion stent graft system in the valiant evo global clinical trial

    Get PDF
    Abstract Objective The Valiant Navion stent graft system (Medtronic, Santa Rosa, Calif) is a new iteration of a thoracic endograft for the treatment of descending thoracic aortic aneurysms. Herein, the 30-day primary safety and efficacy outcomes and secondary end points are presented. Methods The Valiant EVO global clinical trial is a prospective, nonrandomized, single-arm trial. Patient enrollment occurred from April 2016 to October 2017. The primary end point was defined as access and/or deployment failure and/or a major device effect (MDE), including device-related secondary procedures, device-related mortality, conversion to open surgery, or thoracic aortic aneurysm rupture within 30 days of the index procedure. Other measures of stent graft performance including procedural data, rates of secondary procedures, and frequency of endoleaks are also reported. Results Of the 87 consecutive patients undergoing thoracic endovascular aneurysm repair who were enrolled, 33 (37.9%) were female with 61 (70.9%) presenting with severe access artery tortuosity and 66 (85.7%) with high thoracic aortic tortuosity per core laboratory evaluation. The mean procedure duration was 88.7 ± 53.4 minutes and geographical differences existed such as percutaneous access (37/52 [71.2%]) in the United States and surgical cut down in the outside of the U.S. sites (28/35 [80.0%]). There were no access or deployment failures and only 2.3% of the patients (2/87; P Conclusions Access/deployment failures, MDEs, and endoleaks were rare in the first 30 days of the Valiant Evo clinical trial. The Valiant Navion thoracic stent graft system has shown encouraging 30-day results in this challenging cohort and trial patients will continue to be followed through 5 years

    Update on blunt thoracic aortic injury: Fifteen-year single-institution experience

    Get PDF
    ObjectivesDespite improvements in the management of blunt thoracic aortic injury, mortality remains high. We report our experience with blunt thoracic aortic injury at a level 1 trauma center over the past 15 years.MethodsBetween January 1, 1997, and January 1, 2012, data on 338 patients who presented with suspected blunt thoracic aortic injury were entered into the University of Texas Medical School at Houston Trauma Center Registry. A total of 175 patients (52%) underwent thoracic aortic repair; 29 (17%) had open repair with aortic crossclamping, 77 (44%) had open repair with distal aortic perfusion, and 69 (39%) had thoracic endovascular aortic repair. Outcomes were determined, including early mortality, morbidity, length of stay, and late survival. Multiple logistic regression analysis was used to compute adjusted estimates for the effects of the operative technique.ResultsThe early mortality for all patients with blunt thoracic aortic injury was 41% (139/338). Early mortality was 17% (27/175) for operative aortic interventions, 4% (3/69) for thoracic endovascular aortic repairs, 31% (11/29) for open repairs with aortic crossclamping, and 14% (11/77) for open repairs with distal aortic perfusion. Survival for thoracic endovascular aortic repair at 1 year and 5 years was 92% and 87%, respectively. Survival for open repair at 1, 5, 10, and 15 years was 76%, 75%, 72%, and 68%, respectively.ConclusionsBlunt thoracic aortic injury remains associated with significant early mortality. Delayed selective management, when applied with open repair with distal aortic perfusion and the use of thoracic endovascular aortic repair, has been associated with improved early outcomes. The long-term durability of thoracic endovascular aortic repair is unknown, necessitating close radiographic follow-up

    Postoperative renal function preservation with nonischemic femoral arterial cannulation for thoracoabdominal aortic repair.

    Get PDF
    BACKGROUND: Renal failure after thoracoabdominal aortic repair is a significant clinical problem. Distal aortic perfusion for organ and spinal cord protection requires cannulation of the left femoral artery. In 2006, we reported the finding that direct cannulation led to leg ischemia in some patients and was associated with increased renal failure. After this finding, we modified our perfusion technique to eliminate leg ischemia from cannulation. In this article, we present the effects of this change on postoperative renal function. METHODS: Between February 1991 and July 2008, we repaired 1464 thoracoabdominal aortic aneurysms. Distal aortic perfusion was used in 1088, and these were studied. Median patient age was 68 years, and 378 (35%) were women. In September 2006, we began to adopt a sidearm femoral cannulation technique that provides distal aortic perfusion while maintaining downstream flow to the leg. This was used in 167 patients (15%). We measured the joint effects of preoperative glomerular filtration rate (GFR) and cannulation technique on the highest postoperative creatinine level, postoperative renal failure, and death. Analysis was by multiple linear or logistic regression with interaction. RESULTS: The preoperative GFR was the strongest predictor of postoperative renal dysfunction and death. No significant main effects of sidearm cannulation were noted. For peak creatinine level and postoperative renal failure, however, strong interactions between preoperative GFR and sidearm cannulation were present, resulting in reductions of postoperative renal complications of 15% to 20% when GFR was \u3c60 mL\u3e/min/1.73 m(2). For normal GFR, the effect was negated or even reversed at very high levels of GFR. Mortality, although not significantly affected by sidearm cannulation, showed a similar trend to the renal outcomes. CONCLUSION: Use of sidearm cannulation is associated with a clinically important and highly statistically significant reduction in postoperative renal complications in patients with a low GFR. Reduced renal effect of skeletal muscle ischemia is the proposed mechanism. Effects among patients with good preoperative renal function are less clear. A randomized trial is needed
    • …
    corecore