87 research outputs found

    Otoacoustic emissions and medial olivocochlear system: patients with tinnitus and no hearing loss

    Get PDF
    BACKGROUND: tinnitus. AIM: to compare the results of otoacoustic emissions for transitory stimulus (TEOAE) and the functioning of the olivocochlear medial system, in individuals with normal hearing sensibility, with and without tinnitus. METHOD: participants of this study were 60 subjects, with tonal thresholds and acoustic imitance measurements within normal standards, distributed in two groups: group one - 30 subjects with tinnitus and group two - 30 subjects without tinnitus, paired up by gender and age. Both groups were submitted to the TEOAE test, with and without the presence of white contralateral white noise at 60dB NPS. For the 19 subjects who presented unilateral tinnitus, TEOAE and suppression results were compared regarding the variables of side, taking in consideration the presence of tinnitus. RESULTS: in the group comparison, with and without tinnitus, there was no significant statistical difference for the incidence of TEOAE, response levels, and incidence of the suppression effect. Significant statistical difference was not observed between the right and left ears in the group with tinnitus. For the 19 subjects with unilateral tinnitus, a higher amplitude of the responses and a higher suppression incidence were observed for the right ear, as well as a higher incidence of tinnitus and a lower incidence of suppression for the left ear. CONCLUSION: there was no significant statistical difference for both TEOAE incidence and response levels, as well as for the functioning of the olivocochlear medial system between the subjects, with normal hearing sensibility, with and without tinnitus. For the subjects who presented unilateral tinnitus, the overall TEOAE reponse levels was significantly higher in the ear with no tinnitus and the olivocochlear medial system was significantly less efficient in the ear with tinnitus.TEMA: zumbido. OBJETIVO: comparar os resultados das emissões otoacústicas transitório por estímulo (EOAT) e do funcionamento do sistema olivococlear medial, em indivíduos com sensibilidade auditiva normal, com e sem zumbido. MÉTODO: a casuística deste estudo foi composta por 60 sujeitos, com limiares tonais e medidas da imitância acústica dentro dos padrões da normalidade distribuídos em dois grupos: grupo um formado por 30 sujeitos com zumbido e grupo dois por 30 sujeitos sem zumbido, pareados por gênero e idade. Os dois grupos foram submetidos ao teste das EOAT com e sem ruído branco contralateral a 60dB NPS. Em 19 sujeitos que apresentavam zumbido unilateral comparou-se os resultados das EOAT e supressão em relação à variável lado, considerando-se o lado do zumbido. RESULTADOS: na comparação entre os grupos com e sem zumbido não houve diferença estatisticamente significante quanto à ocorrência das EOAT, à amplitude de resposta, e à ocorrência do efeito de supressão. Não se observou diferença estatisticamente significante entre as orelhas direita (OD) e esquerda (OE) no grupo com zumbido. Nos 19 sujeitos com zumbido unilateral, observou-se maior amplitude de resposta e maior ocorrência de supressão à direita e maior ocorrência de zumbido e menor ocorrência de supressão à esquerda. CONCLUSÃO: não houve diferença estatisticamente significante tanto na ocorrência e amplitude de respostas das EOAT quanto no funcionamento do sistema olivococlear medial entre os sujeitos, com sensibilidade auditiva normal, com e sem zumbido. Nos sujeitos que apresentaram zumbido unilateral, observou-se que a amplitude geral das EOAT foi maior na orelha sem zumbido e que o sistema olivococlear medial foi menos eficiente na orelha com zumbido de forma estatisticamente significante.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de MedicinaAudiologia do Centro de Especialização em Fonoaudiologia ClínicaUniversidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Departamento de Otorrinolaringologia e Distúrbios da Comunicação HumanaUNIFESP, EPM, Depto. de Otorrinolaringologia e Distúrbios da Comunicação HumanaSciEL

    Hearing of professional violinists: cochlear function and auditory symmetry study

    Get PDF
    PURPOSE: To verify the occurrence of hearing disorders in violinists and if there is an association with the more exposed ear. METHODS: Subjects were ten violinists, eight female and two male, with ages between 17 and 69, who constituted the Study Group. They were matched according to age and gender with non-musicians with no hearing complaints. Subjects were assessed by pure tone audiometry, speech audiometry, acoustic immitance measures, transient evoked otoacoustic emissions, and distortion product otoacoustic emissions, preceded by otoscopy and anamnesis. The exclusion criterion was altered tympanometry. RESULTS: There was higher occurrence of bilateral tinnitus in the Study Group. It was observed that musicians do not use hearing protector during training and presentations. In pure tone audiometry, there was no difference between thresholds obtained for both groups. It was found higher occurrence of hearing disorders in the left ear, but this difference was not significant. In the transient evoked otoacoustic emission and distortion product otoacoustic emission, there was also no difference between groups, neither in the comparison between ears. CONCLUSION: It was observed higher occurrence of hearing disorders in the group of violinists, with higher percentage of alterations in the left ear. However, the difference between right and left ears was not significant.OBJETIVO: Verificar ocorrência de alterações auditivas em violinistas e se há associação com a orelha mais exposta. MÉTODOS: Foram avaliados dez violinistas, oito do gênero feminino e dois do gênero masculino, de 17 a 69 anos, que constituíram o Grupo Estudo e foram pareados segundo gênero e idade com não-músicos, sem queixas auditivas. Avaliações realizadas por audiometria tonal liminar, logoaudiometria, imitanciometria, emissões otoacústicas evocadas por estímulo transiente e emissões otoacústicas evocadas por produto de distorção, precedidos por meatoscopia e anamnese. Critério de exclusão: curva timpanométrica alterada. RESULTADOS: Houve maior ocorrência de zumbido bilateral no Grupo Estudo. Quanto ao uso de protetor auricular, observou-se que os músicos não utilizam proteção nos treinos e apresentações. Na audiometria tonal liminar, não houve diferença entre os limiares obtidos nos grupos. Apesar da maior ocorrência de alterações auditivas na orelha esquerda, as diferenças não foram significativas. Na pesquisa das emissões otoacústicas evocadas por estímulo transiente e emissões otoacústicas evocadas por produto de distorção, também não houve diferença entre os grupos e na comparação entre as orelhas. CONCLUSÃO: Foi observada maior ocorrência de alterações auditivas no grupo de violinistas, com maior percentual de alterações na orelha esquerda. No entanto, a diferença entre as orelhas direita e esquerda não foi significativa.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Universidade Federal de São Paulo (UNIFESP) Departamento de FonoaudiologiaUNIFESP, Depto. de FonoaudiologiaSciEL

    Visual reinforcement audiometry with different sound stimuli in children

    Get PDF
    BACKGROND: hearing evaluation in children. AIM: to verify the Minimum Response Levels (MRL) through the use of Visual Reinforcement Audiometry (VRA) in the sound field, in 50 normal hearing children and in 25 children with hearing loss, taking into account the following variables: side of sound presentation, gender, age and type of stimulus. METHOD: VRA was performed using pure tone frequency modulation (warble) and the Sonar System. The modulated tones were produced by the Pediatric Audiometer, in the frequencies of 500, 1000, 2000 and 4000Hz and at the intensities of 80, 60, 40 and 20dBNA. The modulated tones were presented in a decreasing sequence of intensity and by using the stimulus-reply-visual reinforcement conditioning. The assessment procedure and analysis of response were the same when using the stimuli of the Sonar System. However, on this occasion, a sound amplification box was used. Each loudspeaker with the visual reinforcement was positioned approximately at 90º azimuth to the right and the left of the child, and at a distance of approximately 50 cm. Visual reinforcement was an illuminated clown. RESULTS: no statistically significant difference was found between the MNL and the side of sound presentation. The MRL at 500Hz and 2000Hz, when using the Sonar System, were lower for normal hearing males. In this group, there was a decrease in the MRL with the increase in age for both stimuli. When comparing the MRL with two stimuli, there was a statistically significant difference in favor of the Sonar System, but only for the group of normal hearing children below two years of age. CONCLUSION: the MRL decrease with age independently of the stimulus and are lower when using the Sonar System. For the group of children with hearing loss no significant difference was found for any of the studied variables.TEMA: avaliação auditiva infantil. OBJETIVO: verificar os Níveis Mínimos de Resposta (NMR) por meio de Audiometria de Reforço Visual (ARV) em campo livre, em 50 crianças ouvintes e 25 deficientes auditivas, considerando as variáveis: lado de apresentação sonora, sexo, idade e tipo de estímulo. MÉTODO: realizou-se ARV com tons puros modulados em freqüência (warble) e com estímulos do Sistema Sonar nas crianças selecionadas. Os tons modulados foram produzidos pelo Audiômetro Pediátrico, nas freqüências de 500, 1000, 2000 e 4000Hz e nas intensidades de 80, 60, 40 e 20dBNA. Sendo estes apresentados em ordem decrescente de intensidade e utilizando o condicionamento estímulo-resposta-reforço visual. Utilizando os estímulos Sistema Sonar, o procedimento de avaliação e a apreciação das respostas foram os mesmos, porém para a apresentação destes foi utilizada uma caixa de amplificação sonora. Cada alto-falante com o reforço visual foi posicionado a aproximadamente a 90 azimute à direita e à esquerda da criança, em uma distância de aproximadamente 50cm. O reforço visual usado foi um palhaço iluminado. RESULTADOS: não houve diferença estatisticamente significante entre MNR em relação ao lado de apresentação. Os NMRs em 500 e 2000Hz do Sistema Sonar, foram menores no sexo masculino nos ouvintes. Neste grupo houve diminuição dos NMR com aumento da idade, para ambos estímulos. Ao comparar NMRs com dois estímulos houve diferença estatisticamente significante a favor do Sistema Sonar apenas para ouvintes com menos de dois anos. CONCLUSÃO: em ouvintes os NMRs reduzem com avanço da idade independente do estímulo e são inferiores com o Sistema Sonar. Nas deficientes auditivas não houve diferença significativa em relação a nenhuma variável estudada.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de MedicinaUniversidade Federal de São Paulo (UNIFESP) Departamento de Fonoaudiologia Núcleo Integrado de Atendimento, Pesquisa e Ensino em AudiçãoUniversidade Federal de São Paulo (UNIFESP) Departamento de FonoaudiologiaUNIFESP, EPMUNIFESP, Depto. de Fonoaudiologia Núcleo Integrado de Atendimento, Pesquisa e Ensino em AudiçãoUNIFESP, Depto. de FonoaudiologiaSciEL

    Cigarette smoking as a risk factor for auditory problems

    Get PDF
    Smoking is a public health concern and we are still unsure of its relation with auditory problems. AIM: To study the effects of cigarette smoking in auditory thresholds, in otoacoustic emissions and in their inhibition by the efferent olivocochlear medial system. MATERIALS AND METHODS: 144 adults from both genders, between 20 and 31 years of age, smoking and non-smoking individuals were submitted to conventional and high-frequency audiometry, transient stimuli otoacoustic emissions and suppression effect investigation. RESULTS: smokers presented worse auditory thresholds in the frequencies of 12.500Hz in the right ear and 14,000 kHz in both ears. Regarding the otoacoustic emissions, smokers group presented a lower response level in the frequencies of 1,000Hz in both ears and 4,000Hz in the left ear. Among smokers there were more cases of cochlear dysfunction and tinnitus. CONCLUSION: Our results suggest that cigarette smoking has an adverse effect on the auditory system.O tabagismo é um problema de saúde pública e ainda não se sabe ao certo sua relação com problemas auditivos. OBJETIVO:Verificar o efeito do cigarro nos limiares audiométricos, na ocorrência das emissões otoacústicas e na inibição das mesmas pelo sistema eferente olivococlear medial. MATERIAL E MÉTODO: 144 adultos de ambos os sexos, entre 20 a 31 anos, fumantes e não fumantes, foram submetidos a audiometria convencional e de alta frequência, emissões otoacústicas por estímulo transiente e a pesquisa do efeito de supressão. RESULTADOS: O grupo de fumantes apresentou limiares auditivos piores nas frequências 12500Hz na orelha direita e 14000Hz em ambas orelhas. Nas emissões otoacústicas apresentou nível de resposta menor nas frequências de 1000Hz em ambas orelhas e 4000Hz na orelha esquerda. O grupo de fumantes também apresentou maior número de casos com disfunção coclear e queixa de zumbido. CONCLUSÃO: Os resultados do estudo sugerem que o cigarro tem um efeito nocivo no sistema auditivo.Universidade Federal de São Paulo (UNIFESP)UNIFESPSciEL

    Potenciais evocados auditivos em lactentes pré-termo e a termo

    Get PDF
    Accurate information about type, degree, and configuration of hearing loss are necessary for successful audiological early interventions. Auditory brainstem response with tone burst stimuli (TB ABR) and auditory steady-state response (ASSR) exams provide this information. AIM: To analyze the clinical applicability of TB ABR and ASSR at 2 kHz in infants, comparing responses in full-term and premature neonates. MATERIAL AND METHOD: The study was cross-sectional, clinical and experimental. Subjects consisted of 17 premature infants and 19 full-term infants. TB ABR and ASSR exams at 2000 Hz were done during natural sleep. RESULTS: The electrophysiological minimum response obtained with TB ABR was 32.4 dBnHL (52.4 dBSPL); the ASSR minimum was 13.8 dBHL (26.4 dBSPL). The exams required 21.1 min and 22 min, respectively. Premature and full-term infant responses showed no statistically significant differences, except for auditory steady-state response duration. CONCLUSIONS: Both exams have clinical applicability at 2 kHz in infants, with 20 min of duration, on average. In general, there are no differences between premature and full-term individuals.O sucesso de uma intervenção audiológica precoce depende de informações precisas quanto ao tipo, grau e configuração da perda auditiva. O potencial evocado auditivo de tronco encefálico com o estímulo tone burst (PEATE TB) e a resposta auditiva de estado estável (RAEE) proporcionam tais informações. OBJETIVO: Investigar a aplicabilidade clínica, em lactentes, do PEATE TB e da RAEE na frequência de 2 kHz, comparando as respostas dos lactentes nascidos a termo e prétermo. MATERIAL E MÉTODO: O estudo (transversal, clínico e experimental) foi realizado com uma casuística de 17 lactentes pré-termo e 19 a termo submetidos ao PEATE TB e RAEE em 2000 Hz. RESULTADOS: A resposta eletrofisiológica mínima obtida com o PEATE TB foi de 32,4 dBnNA (52,4 dBNPS) e com a RAEE de 13,8 dBNA (26,4 dBNPS), com duração média de 21,1 min e 22 min, respectivamente. A comparação das respostas dos lactentes pré-termo e a termo não apresentou diferenças estatisticamente significantes, com exceção do tempo de duração da RAEE. CONCLUSÃO: As duas metodologias têm aplicabilidade clínica na frequência de 2 kHz em lactentes, com duração média de 20 min. Lactentes nascidos pré-termo, no geral, não apresentam diferenças em relação aos lactentes nascidos a termo.Medical Specialty Outpatient UnitUNIFESPUNIFESPSciEL

    Temporal resolution: analysis in term and preterm preschoolers

    Get PDF
    BACKGROUND: auditory processing. AIM: to verify the hearing behavior of temporal resolution in children with ages from five to six years, who were born preterm, with no evidence of neurological alterations and to compare this behavior to that observed in children of the same age, who were born at term, with low risk for developmental disorders, taking into consideration the variables of: threshold detection gaps through pre-established frequency, binaural and monaural presentation, order of stimuli presentation and gender. METHOD: 70 children divided in two groups: Group 1 with 44 children who were born at term (20 female and 24 male) and Group 2 with 26 preterm children (12 female and 14 male). Children were submitted to audiologic evaluation composed of audiometry, speech response threshold, acoustic impedance test and the Random Gap Detection Test (RGDT). RESULTS: children who were born at term presented lower threshold detection gaps in the RGDT, for both monaural and binaural stimuli presentation, in all of the pre-established frequencies when compared to preterm children. This difference between the groups was statistically significant. The average threshold detection gaps of Group 1 rose according to the increase of frequency. For Group 2 statistically significant differences were not found regarding the average of threshold detection gaps, for both monaural and binaural stimuli presentation. CONCLUSION: preterm children differ from those born at term regarding the hearing behavior of temporal resolution. The RGDT can be used as a tool to evaluate the hearing process, once the early detection of alterations in temporal processes indicates the need for intervention in order to minimize or avoid future language impairments.TEMA: processamento auditivo. OBJETIVO: verificar o comportamento auditivo de resolução temporal de crianças na faixa etária de cinco a seis anos, nascidas pré-termo, sem evidências de alterações neurológicas e compará-lo com o mesmo comportamento auditivo de crianças na mesma faixa etária, nascidas a termo, com baixo risco para alteração do desenvolvimento, considerando as variáveis: limiar de detecção de intervalo de tempo por freqüência sonora pré-estabelecida apresentada na forma binaural e monoaural por ordem de orelha que iniciou o teste e gênero. MÉTODO: 70 sujeitos: 44 nascidos a termo reunidos em grupos de 20 indivíduos do sexo feminino e 24 do sexo masculino, denominado Grupo 1, e 26 nascidos pré-termo, sendo 12 indivíduos do sexo feminino e 14 do sexo masculino, denominado Grupo 2, foram submetidos a avaliação audiológica composta por audiometria tonal limiar, limiar de reconhecimento de fala, imitânciometria e aplicação do teste de fusão auditiva denominado de Random Gap Detection. RESULTADOS: os nascidos a termo apresentaram menores limiares de detecção de intervalo de tempo no teste de fusão auditiva, nas formas de apresentação binaural e monoaural em todas as freqüências sonoras pré-estabelecidas, do que os nascidos pré-termo com diferença estatisticamente significante. As médias dos limiares de detecção de intervalo de tempo do Grupo 1 aumentaram conforme a freqüência sonora aumentou. No Grupo 2 não foram encontradas diferenças estatisticamente significantes quanto as médias de limiares de detecção de intervalo de tempo na forma de apresentação binaural e monoaural. CONCLUSÃO: os nascidos pré-termo se diferenciam dos nascidos a termo quanto ao comportamento auditivo de resolução temporal e o teste de fusão auditiva utilizado pode servir como ferramenta para a avaliação do processamento auditivo, uma vez que a detecção precoce de alteração dos processos temporais indica uma intervenção para minimizar ou evitar futuros prejuízos de linguagem.Universidade Federal de São Paulo (UNIFESP) Departamento de FonoaudiologiaUNIFESP, Depto. de FonoaudiologiaSciEL

    Audiological evaluation in infants with agenesis of the corpus callosum

    Get PDF
    Purposeto assess the occurrence of hearing loss in infants with corpus callosum agenesis comparing them to children without such malformation. Methoda cohort study in two parts: a retrospective from 2008 to 2011, and prospective from 2011 to 2012. The study group consisted of 12 infants diagnosed with agenesis of the corpus callosum and the control group of 12 infants, matched for sex and post conceptional age. All patients underwent otoacoustic emissions transient stimulus, Auditory Evoked Potential (analysis of the average latencies of waves I, III and V and interpeak I-III, III-V and IV 80dBnNA) and behavioral auditory tests. Resultthe analysis of the occurrence of hearing impairment evaluationotoacoustic emissions transient stimulusand Auditory Evoked Potential showed differences in both groups, withhighest percentage of normal results in the control group. There was significant difference between the ears, the latencies of wave III and I-III interpeak interval, and lower right in the control group. In behavioral assessment, there was significant difference between the groups in relation to normal and abnormal results, with higher prevalence of central alteration in the study group. Also in this group, the second assessment showed a statistically significant higher rate of abnormal results when compared to the first assessment. Conclusionhearing disorders in infants with corpus callosum agenesis were not identified at birth, but within the first six months of life. Most of the changes occurred in the central auditory pathway in the brainstem.Purposeto assess the occurrence of hearing loss in infants with corpus callosum agenesis comparing them to children without such malformation. Methoda cohort study in two parts: a retrospective from 2008 to 2011, and prospective from 2011 to 2012. The study group consisted of 12 infants diagnosed with agenesis of the corpus callosum and the control group of 12 infants, matched for sex and post conceptional age. All patients underwent otoacoustic emissions transient stimulus, Auditory Evoked Potential (analysis of the average latencies of waves I, III and V and interpeak I-III, III-V and IV 80dBnNA) and behavioral auditory tests. Resultthe analysis of the occurrence of hearing impairment evaluationotoacoustic emissions transient stimulusand Auditory Evoked Potential showed differences in both groups, withhighest percentage of normal results in the control group. There was significant difference between the ears, the latencies of wave III and I-III interpeak interval, and lower right in the control group. In behavioral assessment, there was significant difference between the groups in relation to normal and abnormal results, with higher prevalence of central alteration in the study group. Also in this group, the second assessment showed a statistically significant higher rate of abnormal results when compared to the first assessment. Conclusionhearing disorders in infants with corpus callosum agenesis were not identified at birth, but within the first six months of life. Most of the changes occurred in the central auditory pathway in the brainstem.Objetivoverificar a ocorrência de alterações auditivas em lactentes com alteração do corpo caloso, comparando-os a crianças sem tal malformação. Métodoestudo de coorte dividido em duas partes: retrospectivo de 2008 a 2011 e prospectivo de 2011 a 2012. O grupo estudo foi constituído por 12 lactentes com diagnóstico de agenesia de corpo caloso e o grupo controlepor12 lactentes, pareados por idade pós concepcional e sexo. Todos realizaram Emissões Otoacústicas Evocadas por Estimulo Transiente, Potencial Evocado Auditivo de Tronco Encefálico (análise da média das latências das ondas I, III e V e interpicos I-III, III-V e I-V a 80dBnNA) e Avaliação do Comportamento Auditivo. Resultadona análise da ocorrência de alteração auditiva na avaliação com Emissões Otoacústicas Transientes e Potencial Evocado Auditivo de Tronco Encefálico, houve diferença em ambos os grupos com maior percentual de resultados normais no grupo controle. Houve diferença significante entre as orelhas, nas latências da onda III e intervalo interpico I-III, menor à direita, nogrupo controle.Naavaliação comportamental, houve diferença significante entre os grupos em relação aos resultados normais e alterados, com maior ocorrência de alteração central no grupo estudo.Ainda neste grupo, a segunda avaliação mostrou maior índice de resultados alterados quando comparados à primeira avaliação, sendo estaticamente significante. Conclusãoas alterações auditivas nos lactentes com alteração do corpo caloso não foram identificadas ao nascimento, tendo sido apenas a partir de seis meses de vida. A maioria das alterações ocorreram na via auditiva central, no tronco encefálico.Departamento de Fonoaudiologia Departamento de FonoaudiologiaEscola Paulista de Medicina Escola Paulista de MedicinaUniversidade Federal de São Paulo (UNIFESP)Universidade Federal de São Paulo (UNIFESP) Clinica do Hospital São PauloUniversidade Federal de São Paulo (UNIFESP) Escola Paulista de MedicinaUNIFESP, EPM, Escola Paulista de MedicinaEPM (EPM), Clinica do Hospital São PauloEPM, Escola Paulista de MedicinaSciEL

    The efficacy of hearing aids on diminishing or eliminating tinnitus

    Get PDF
    Tinnitus is a disorder extremely frequent in patients with hearing loss. It affects more than 40 milion people in the USA, affecting about 1/3 of the population above 65 years old. Clinical experience has been demonstrating that patients with hearing loss and tinnitus have great benefits with the hearing aid because it helps out the comprehension of conversation while relieves tinnitus. AIM: In this work, we have studied the efficacy of hearing aids on diminishing or eliminating tinnitus in patients with hearing loss. STUDY DESIGN: Series study. MATERIAL AND METHOD: We evaluated 47 patients (32 women and 15 men) with ages ranging from 32 to 88 years old and medical indication for fitting a hearing aid. We subjectively investigated the sensation of tinnitus matching frequency (Hz) and loudness (dB) through the technic of acuphenometry and we have attended the patients for one year aiming to verify if there was a relief of tinnitus after the hearing aid fitting. RESULTS: The majority of patients (87,2%) refered relief of tinnitus with the use of the hearing aid. In 51% of these patients tinnitus has completely desapeared. It was necessary to use the hearing aid for some months (3-8) to obtain the relief of tinnitus in the majority of patients. The characteristics of the hearing aids, as model, tecnology and vent, had no influence on the relief of tinnitus. CONCLUSIONS: The use of the hearing aid was effective in reducing or eliminating tinnitus in patients with hearing loss and tinnitus.O zumbido é uma desordem extremamente freqüente em pacientes com perda auditiva, atingindo cerca de 40 milhões de pessoas nos EUA, afetando aproximadamente 1/3 da população acima dos 65 anos de idade. A prática clínica tem demonstrado que pacientes portadores de perda auditiva associada a zumbido beneficiam-se com o uso de próteses auditivas, pois estas, além de melhorarem a compreensão da conversação, aliviam o zumbido. OBJETIVO: No presente trabalho, procurou-se verificar a eficiência da adaptação de próteses auditivas na redução ou eliminação do zumbido em pacientes com perda auditiva. FORMA DE ESTUDO: Estudo de série. MATERIAL E MÉTODO: Foram avaliados 47 indivíduos adultos, sendo 32 do sexo feminino e 15 do sexo masculino, com idades entre 32 e 88 anos, com indicação médica para adaptação de prótese auditiva. Realizou-se análise e avaliação subjetiva da sensação de zumbido por meio da técnica da acufenometria, caracterizando-o quanto ao pitch e loudness, e acompanhamento dos pacientes durante um ano afim de verificar se houve melhora do zumbido após a adaptação da prótese auditiva. RESULTADOS: A maioria dos pacientes (87,2%) referiu melhora do zumbido com o uso da prótese auditiva, sendo que em 51% destes o zumbido desapareceu completamente. O tempo de uso da prótese necessário para a melhora do zumbido foi de 3 a 8 meses para a maioria dos indivíduos. As características da prótese auditiva, como modelo, tecnologia e ventilação, não influenciaram a melhora do zumbido. CONCLUSÃO: A adaptação de próteses auditivas mostrou-se eficaz na redução ou eliminação do zumbido em pacientes portadores de perda auditiva associada a zumbido.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de MedicinaUNIFESP, EPMSciEL
    • …
    corecore