271 research outputs found

    Notes on the integration of numerical relativity waveforms

    Full text link
    A primary goal of numerical relativity is to provide estimates of the wave strain, hh, from strong gravitational wave sources, to be used in detector templates. The simulations, however, typically measure waves in terms of the Weyl curvature component, ψ4\psi_4. Assuming Bondi gauge, transforming to the strain hh reduces to integration of ψ4\psi_4 twice in time. Integrations performed in either the time or frequency domain, however, lead to secular non-linear drifts in the resulting strain hh. These non-linear drifts are not explained by the two unknown integration constants which can at most result in linear drifts. We identify a number of fundamental difficulties which can arise from integrating finite length, discretely sampled and noisy data streams. These issues are an artifact of post-processing data. They are independent of the characteristics of the original simulation, such as gauge or numerical method used. We suggest, however, a simple procedure for integrating numerical waveforms in the frequency domain, which is effective at strongly reducing spurious secular non-linear drifts in the resulting strain.Comment: 23 pages, 10 figures, matches final published versio

    Enhanced uptake of nanoparticle drug carriers via a thermoresponsive shell enhances cytotoxicity in a cancer cell line

    Get PDF
    Polymer particles consisting of a biodegradable poly[lactide-co-glycolide] (PLGA) core and a thermoresponsive shell have been formulated to encapsulate the dye rhodamine 6G and the potent cytotoxic drug paclitaxel. Cellular uptake of these particles is significantly enhanced above the thermal transition temperature (TTT) of the polymer shells in the human breast carcinoma cell line MCF-7 as determined by flow cytometry and fluorescence microscopy. Paclitaxel-loaded particles display reduced and enhanced cytotoxicity below and above the TTT respectively compared to unencapsulated drug. The data suggests a potential route to enhanced anti-cancer efficacy through temperature-mediated cell targeting.© The Royal Society of Chemistry 2013

    Connecting Numerical Relativity and Data Analysis of Gravitational Wave Detectors

    Full text link
    Gravitational waves deliver information in exquisite detail about astrophysical phenomena, among them the collision of two black holes, a system completely invisible to the eyes of electromagnetic telescopes. Models that predict gravitational wave signals from likely sources are crucial for the success of this endeavor. Modeling binary black hole sources of gravitational radiation requires solving the Eintein equations of General Relativity using powerful computer hardware and sophisticated numerical algorithms. This proceeding presents where we are in understanding ground-based gravitational waves resulting from the merger of black holes and the implications of these sources for the advent of gravitational-wave astronomy.Comment: Appeared in the Proceedings of 2014 Sant Cugat Forum on Astrophysics. Astrophysics and Space Science Proceedings, ed. C.Sopuerta (Berlin: Springer-Verlag

    Integrated organic light-emitting device/fluorescence-based chemical sensors

    Full text link
    A fluorescent chemical sensor platform, integrating an organic light-emitting device (OLED) light-source with a fluorescent probe, is demonstrated for a subsecond-fast oxygen sensor. The integration results in strong light coupling and negligible heating of the sensor film or analyte. The potential in vivo operation of compact, stand-alone, battery-powered, OLED-based miniaturized sensor arrays for chemical and biological applications is discussed. © 2002 American Institute of Physics.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/69695/2/APPLAB-81-24-4652-1.pd

    Effect of calibration errors on Bayesian parameter estimation for gravitational wave signals from inspiral binary systems in the advanced detectors era: Further investigations

    Get PDF
    By 2015, the advanced versions of the gravitational wave detectors Virgo and LIGO will be online. They will collect data in coincidence with enough sensitivity to potentially deliver multiple detections of gravitational waves from inspirals of compact-object binaries. In a previous work, we have studied the effects introduced in the estimation of the physical parameters of the source by uncertainties in the calibration of the interferometers. Our bias estimator for parameter errors introduced by calibration uncertainties consisted of two terms: A genuine bias due to the calibration errors, and a contribution coming from the limited number of samples used to explore the parameter space. In this article, we have focused on this second term, and we have shown how it is smaller than the former (about 10 times smaller), and how it decreases as the signal-to-noise rati

    Characteristic extraction in numerical relativity: binary black hole merger waveforms at null infinity

    Full text link
    The accurate modeling of gravitational radiation is a key issue for gravitational wave astronomy. As simulation codes reach higher accuracy, systematic errors inherent in current numerical relativity wave-extraction methods become evident, and may lead to a wrong astrophysical interpretation of the data. In this paper, we give a detailed description of the Cauchy-characteristic extraction technique applied to binary black hole inspiral and merger evolutions to obtain gravitational waveforms that are defined unambiguously, that is, at future null infinity. By this method we remove finite-radius approximations and the need to extrapolate data from the near zone. Further, we demonstrate that the method is free of gauge effects and thus is affected only by numerical error. Various consistency checks reveal that energy and angular momentum are conserved to high precision and agree very well with extrapolated data. In addition, we revisit the computation of the gravitational recoil and find that finite radius extrapolation very well approximates the result at \scri. However, the (non-convergent) systematic differences to extrapolated data are of the same order of magnitude as the (convergent) discretisation error of the Cauchy evolution hence highlighting the need for correct wave-extraction.Comment: 41 pages, 8 figures, 2 tables, added references, fixed typos. Version matches published version

    Gold–Oligonucleotide Nanoconstructs Engineered to Detect Conserved Enteroviral Nucleic Acid Sequences

    Get PDF
    Enteroviruses are ubiquitous mammalian pathogens that can produce mild to life-threatening disease. We developed a multimodal, rapid, accurate and economical point-of-care biosensor that can detect nucleic acid sequences conserved amongst 96% of all known enteroviruses. The biosensor harnesses the physicochemical properties of gold nanoparticles and oligonucleotides to provide colourimetric, spectroscopic and lateral flow-based identification of an exclusive enteroviral nucleic acid sequence (23 bases), which was identified through in silico screening. Oligonucleotides were designed to demonstrate specific complementarity towards the target enteroviral nucleic acid to produce aggregated gold–oligonucleotide nanoconstructs. The conserved target enteroviral nucleic acid sequence (≥1 × 10−7 M, ≥1.4 × 10−14 g/mL) initiates gold–oligonucleotide nanoconstruct disaggregation and a signal transduction mechanism, producing a colourimetric and spectroscopic blueshift (544 nm (purple) > 524 nm (red)). Furthermore, lateral-flow assays that utilise gold–oligonucleotide nanoconstructs were unaffected by contaminating human genomic DNA, demonstrated rapid detection of conserved target enteroviral nucleic acid sequence

    Gold–Oligonucleotide Nanoconstructs Engineered to Detect Conserved Enteroviral Nucleic Acid Sequences

    Get PDF
    From MDPI via Jisc Publications RouterHistory: accepted 2021-07-07, pub-electronic 2021-07-14Publication status: PublishedFunder: Innovate UK; Grant(s): Partnership Number: 9971Funder: Engineering and Physical Sciences Research Council; Grant(s): EP/M027333/1, EP/P006485/1Funder: University of Nottingham; Grant(s): Nottingham Research FellowshipEnteroviruses are ubiquitous mammalian pathogens that can produce mild to life-threatening disease. We developed a multimodal, rapid, accurate and economical point-of-care biosensor that can detect nucleic acid sequences conserved amongst 96% of all known enteroviruses. The biosensor harnesses the physicochemical properties of gold nanoparticles and oligonucleotides to provide colourimetric, spectroscopic and lateral flow-based identification of an exclusive enteroviral nucleic acid sequence (23 bases), which was identified through in silico screening. Oligonucleotides were designed to demonstrate specific complementarity towards the target enteroviral nucleic acid to produce aggregated gold–oligonucleotide nanoconstructs. The conserved target enteroviral nucleic acid sequence (≥1 × 10−7 M, ≥1.4 × 10−14 g/mL) initiates gold–oligonucleotide nanoconstruct disaggregation and a signal transduction mechanism, producing a colourimetric and spectroscopic blueshift (544 nm (purple) > 524 nm (red)). Furthermore, lateral-flow assays that utilise gold–oligonucleotide nanoconstructs were unaffected by contaminating human genomic DNA, demonstrated rapid detection of conserved target enteroviral nucleic acid sequence (60 s), and could be interpreted with a bespoke software and hardware electronic interface. We anticipate that our methodology will translate in silico screening of nucleic acid databases to a tangible enteroviral desktop detector, which could be readily translated to related organisms. This will pave the way forward in the clinical evaluation of disease and complement existing strategies to overcome antimicrobial resistance

    Effect of calibration errors on Bayesian parameter estimation for gravitational wave signals from inspiral binary systems in the advanced detectors era

    Full text link
    By 2015 the advanced versions of the gravitational-wave detectors Virgo and LIGO will be online. They will collect data in coincidence with enough sensitivity to potentially deliver multiple detections of gravitation waves from inspirals of compact-object binaries. This work is focused on understanding the effects introduced by uncertainties in the calibration of the interferometers. We consider plausible calibration errors based on estimates obtained during LIGO's fifth and Virgo's third science runs, which include frequency-dependent amplitude errors of ∼10\sim 10% and frequency-dependent phase errors of ∼3\sim 3 degrees in each instrument. We quantify the consequences of such errors estimating the parameters of inspiraling binaries. We find that the systematics introduced by calibration errors on the inferred values of the chirp mass and mass ratio are smaller than 20% of the statistical measurement uncertainties in parameter estimation for 90% of signals in our mock catalog. Meanwhile, the calibration-induced systematics in the inferred sky location of the signal are smaller than ∼50\sim 50% of the statistical uncertainty. We thus conclude that calibration-induced errors at this level are not a significant detriment to accurate parameter estimation.Comment: 21 figures, 5 table

    The Current Status of Binary Black Hole Simulations in Numerical Relativity

    Full text link
    Since the breakthroughs in 2005 which have led to long term stable solutions of the binary black hole problem in numerical relativity, much progress has been made. I present here a short summary of the state of the field, including the capabilities of numerical relativity codes, recent physical results obtained from simulations, and improvements to the methods used to evolve and analyse binary black hole spacetimes.Comment: 14 pages; minor changes and corrections in response to referee
    • …
    corecore