211 research outputs found

    Direct measurement of molecular mobility and crystallisation of amorphous pharmaceuticals using terahertz spectroscopy.

    Get PDF
    Despite much effort in the area, no comprehensive understanding of the formation and behaviour of amorphous solids has yet been achieved. This severely limits the industrial application of such materials, including drug delivery where, in principle, amorphous solids have demonstrated their great usefulness in increasing the bioavailability of poorly aqueous soluble active pharmaceutical ingredients. Terahertz time-domain spectroscopy is a relatively novel analytical technique that can be used to measure the fast molecular dynamics of molecules with high accuracy in a non-contact and non-destructive fashion. Over the past decade a number of applications for the characterisation of amorphous drug molecules and formulations have been developed and it has been demonstrated how this technique can be used to determine the onset and strength in molecular mobility that underpins the crystallisation of amorphous drugs. In this review we provide an overview of the history, fundamentals and future perspective of pharmaceutical applications related to the terahertz dynamics of amorphous systems.We would like to acknowledge the U.K. Engineering and Physical Sciences Research Council (EP/J007803/1) as well as MedImmune for funding.This is the author accepted manuscript. The final version is available from Elsevier via http://dx.doi.org/10.1016/j.addr.2015.12.02

    Thermal Decoupling of Molecular-Relaxation Processes from the Vibrational Density of States at Terahertz Frequencies in Supercooled Hydrogen-Bonded Liquids.

    Get PDF
    At terahertz frequencies, the libration-vibration motions couple to the dielectric relaxations in disordered hydrogen-bonded solids. The interplay between these processes is still poorly understood, in particular at temperatures below the glass transition temperature, Tg, yet this behavior is of vital importance for the molecular mobility of such materials to remain in the amorphous phase. A series of polyhydric alcohols were studied at temperatures between 80 and 310 K in the frequency range of 0.2-3 THz using terahertz time-domain spectroscopy. Three universal features were observed in the dielectric losses, ϵ″(ν): (a) At temperatures well below the glass transition, ϵ″(ν) comprises a temperature-independent microscopic peak, which persists into the liquid phase and which is identified as being due to librational/torsional modes. For 0.65 Tg < T < Tg, additional thermally dependent contributions are observed, and we found strong evidence for its relation to the Johari-Goldstein secondary β-relaxation process. (b) Clear spectroscopic evidence is found for a secondary β glass transition at 0.65 Tg, which is not related to the fragility of the glasses. (c) At temperatures above Tg, the losses become dominated by primary α-relaxation processes. Our results show that the thermal changes in the losses seem to be underpinned by a universal change in the hydrogen bonding structure of the samples.J.S. would like to thank the U. K. Engineering and Physical Sciences Research Council for financial support.This is the final published version, which can also be viewed on the publisher's website at: http://pubs.acs.org/doi/pdf/10.1021/jz500730

    Quantifying Pharmaceutical Film Coating with Optical Coherence Tomography and Terahertz Pulsed Imaging: An Evaluation.

    Get PDF
    Spectral domain optical coherence tomography (OCT) has recently attracted a lot of interest in the pharmaceutical industry as a fast and non-destructive modality for quantification of thin film coatings that cannot easily be resolved with other techniques. Because of the relative infancy of this technique, much of the research to date has focused on developing the in-line measurement technique for assessing film coating thickness. To better assess OCT for pharmaceutical coating quantification, this paper evaluates tablets with a range of film coating thickness measured using OCT and terahertz pulsed imaging (TPI) in an off-line setting. In order to facilitate automated coating quantification for film coating thickness in the range of 30-200 μm, an algorithm that uses wavelet denoising and a tailored peak finding method is proposed to analyse each of the acquired A-scan. Results obtained from running the algorithm reveal an increasing disparity between the TPI and OCT measured intra-tablet variability when film coating thickness exceeds 100 μm. The finding further confirms that OCT is a suitable modality for characterising pharmaceutical dosage forms with thin film coatings, whereas TPI is well suited for thick coatings.The authors would like to acknowledge the financial support from UK EPSRC Research Grant EP/L019787/1 and EP/L019922/1.This is the final version of the article. It first appeared from Wiley via http://dx.doi.org/10.1002/jps.2453

    Predicting Crystallization of Amorphous Drugs with Terahertz Spectroscopy.

    Get PDF
    There is a controversy about the extent to which the primary and secondary dielectric relaxations influence the crystallization of amorphous organic compounds below the glass transition temperature. Recent studies also point to the importance of fast molecular dynamics on picosecond-to-nanosecond time scales with respect to the glass stability. In the present study we provide terahertz spectroscopy evidence on the crystallization of amorphous naproxen well below its glass transition temperature and confirm the direct role of Johari-Goldstein (JG) secondary relaxation as a facilitator of the crystallization. We determine the onset temperature Tβ above which the JG relaxation contributes to the fast molecular dynamics and analytically quantify the level of this contribution. We then show there is a strong correlation between the increase in the fast molecular dynamics and onset of crystallization in several chosen amorphous drugs. We believe that this technique has immediate applications to quantify the stability of amorphous drug materials.JS and JAZ would like to acknowledge the UK Engineering and Physical Sciences Research Council for funding (EP/J007803/1).This is the final version of the article. It first appeared from ACS at http://dx.doi.org/10.1021/acs.molpharmaceut.5b0033

    Concomitant polymorphism and the martensitic-like transformation of an organic crystal.

    Get PDF
    Crystalline polymorphism is a phenomenon that occurs in many molecular solids, resulting in a diverse range of possible bulk structures. Temperature and pressure can often be used to thermodynamically control which crystal form is preferred, and the associated transitions between polymorphic phases are often discontinuous and complete. N-Methyl-4-carboxypyridinium chloride is a solid that undergoes an apparent continuous temperature-dependent phase transition from an orthorhombic to a monoclinic polymorph. However, a hybrid characterization approach using single-crystal X-ray diffraction, terahertz time-domain spectroscopy, and solid-state density functional theory reveals the transformation to be actually a slowly changing ratio of the two discrete polymorphic forms. The potential energy surface of this process can be directly accessed using terahertz radiation, and the data show that a very low barrier (43.3 J mol-1) exists along the polymorph transformation coordinate

    Resolving the Origins of Crystalline Anharmonicity Using Terahertz Time-Domain Spectroscopy and ab Initio Simulations.

    Get PDF
    Anharmonicity has been shown to be an important piece of the fundamental framework that dictates numerous observable phenomena. In particular, anharmonicity is the driving force of vibrational relaxation processes, mechanisms that are integral to the proper function of numerous chemical processes. However, elucidating its origins has proven difficult due to experimental and theoretical challenges, specifically related to separating the anharmonic contributions from other unrelated effects. While no one technique is particularly suited for providing a complete picture of anharmonicity, by combining multiple complementary methods such a characterization can be made. In this study the role of individual atomic interactions on the anharmonic properties of crystalline purine, the building block of many DNA and RNA nucleobases, is studied by experimental terahertz time-domain spectroscopy and first-principles density functional theory (DFT) and ab initio molecular dynamics simulations (AIMD). In particular, the detailed vibrational information provided by the DFT calculations is used to interpret the atomic origins of anharmonic-related effects as determined by the AIMD calculations, which are in good agreement with the experimental data. The results highlight that anharmonicity is especially pronounced in the intermolecular interactions, particularly along the amine hydrogen bond coordinate, and yields valuable insight into what is similarly observed complex biosystems and crystalline solids.Engineering and Physical Sciences Research Council (EP/N022769/1

    Determination of Water Content in Dehydrated Mammalian Cells Using Terahertz Pulsed Imaging: A Feasibility Study

    Get PDF
    This is the accepted version of the following article: Chau, D., Dennis, A. R., Lin, H., Zeitler, J. A., Tunnacliffe, A., ‘Determination of Water Content in Dehydrated Mammalian Cells Using Terahertz Pulsed Imaging: A Feasibility Study’, Current Pharmaceutical Biotechnology 17(2): 200-207, February 2016. Subject to 12 months' embargo. Embargo end date: 1 February 2017. The published manuscript is available at http://www.eurekaselect.com/136239/articleMammalian cells are involved in a range of biotechnological applications and more recently have been increasingly exploited in regenerative medicine. Critical to successful applications involving mammalian cells are their long-term storage and transport, for which cryopreservation in liquid nitrogen is the most frequently used strategy. However, cryopreservation suffers from high costs, difficulties in transport logistics and the use of undesirable additives (e.g. animal sera or DMSO). An alternative approach, proposed as low cost, low maintenance and process-compatible, is viable desiccation of mammalian cells. Several groups claim to have achieved this, but the extent of desiccation in the cell samples concerned is not always clear, in part because of difficulties in determining very low water content. Although several techniques exist that are frequently used to quantify the amount of water in samples (e.g. FTIR spectroscopy, thermogravimetric analysis (TGA), NMR spectroscopy), the complexity of sample preparation, as well as the costs and time constraints involved are disadvantageous. Here, we assess a novel, rapid and low cost technique, i.e. terahertz (THz) spectroscopy, for the quantification of water content within dehydrated mammalian cell samples.Peer reviewe

    Diffusion and swelling measurements in pharmaceutical powder compacts using terahertz pulsed imaging.

    Get PDF
    Tablet dissolution is strongly affected by swelling and solvent penetration into its matrix. A terahertz-pulsed imaging (TPI) technique, in reflection mode, is introduced as a new tool to measure one-dimensional swelling and solvent ingress in flat-faced pharmaceutical compacts exposed to dissolution medium from one face of the tablet. The technique was demonstrated on three tableting excipients: hydroxypropylmethyl cellulose (HPMC), Eudragit RSPO, and lactose. Upon contact with water, HPMC initially shrinks to up to 13% of its original thickness before undergoing expansion. HPMC and lactose were shown to expand to up to 20% and 47% of their original size in 24 h and 13 min, respectively, whereas Eudragit does not undergo dimensional change. The TPI technique was used to measure the ingress of water into HPMC tablets over a period of 24 h and it was observed that water penetrates into the tablet by anomalous diffusion. X-ray microtomography was used to measure tablet porosity alongside helium pycnometry and was linked to the results obtained by TPI. Our results highlight a new application area of TPI in the pharmaceutical sciences that could be of interest in the development and quality testing of advanced drug delivery systems as well as immediate release formulations.We would like to thank Huxley Bertram Engineering Ltd.,Cambridge, UK for making time available on the compactionsimulator and Martin Bennett from Huxley Bertram for helppreparing samples. We would also like to acknowledge EvonikIndustries, Germany for providing Eudragit RSPO. S.Y. wouldlike to thank the UK Engineering and Physical Sciences Re-search Council for financial support.This is the final version of the article. It was originally published online in the Journal of Pharmaceutical Sciences, 2015, doi: 10.1002/jps.24376

    Non-destructive determination of disintegration time and dissolution in immediate release tablets by terahertz transmission measurements

    Get PDF
    Purpose: The aim of this study was to establish the suitability of terahertz (THz) transmission measurements to accurately measure and predict the critical quality attributes of disintegration time and the amount of active pharmaceutical ingredient (API) dissolved after 15, 20 and 25 min for commercial tablets processed at production scale. Methods: Samples of 18 batches of biconvex tablets from a production-scale design of experiments study into exploring the design space of a commercial tablet manufacturing process were used. The tablet production involved the process steps of high-shear wet granulation, fluid-bed drying and subsequent compaction. The 18 batches were produced using a 4 factor split plot design to study the effects of process changes on the disintegration time. Non-destructive and contactless terahertz transmission measurements of the whole tablets without prior sample preparation were performed to measure the effective refractive index and absorption coefficient of 6 tablets per batch. Results: The disintegration time (R2 = 0.86) and API dissolved after 15 min (R2 = 0.96) linearly correlates with the effective refractive index, neff, measured at terahertz frequencies. In contrast, no such correlation could be established from conventional hardness measurements. The magnitude of neff represents the optical density of the sample and thus it reflects both changes in tablet porosity as well as granule density. For the absorption coefficient, αeff, we observed a better correlation with dissolution after 20 min (R2 = 0.96) and a weaker correlation with disintegration (R2 = 0.83) compared to neff. Conclusion: The measurements of neff and αeff provide promising predictors for the disintegration and dissolution time of tablets. The high penetration power of terahertz radiation makes it possible to sample a significant volume proportion of a tablet without any prior sample preparation. Together with the short measurement time (seconds), the potential to measure content uniformity and the fact that the method requires no chemometric models this technology shows clear promise to be established as a process analyser to non-destructively predict critical quality attributes of tablets
    corecore