37 research outputs found

    In-Stent CTO Percutaneous Coronary Intervention: Individual Patient Data Pooled Analysis of 4 Multicenter Registries

    Get PDF
    OBJECTIVES: The authors sought to examine the outcomes of percutaneous coronary intervention (PCI) for in-stent restenosis (ISR) chronic total occlusions (CTOs). BACKGROUND: The outcomes of PCI for ISR CTOs have received limited study. METHODS: The authors examined the clinical and angiographic characteristics and procedural outcomes of 11,961 CTO PCIs performed in 11,728 patients at 107 centers in Europe, North America, Latin America, and Asia between 2012 and 2020, pooling patient-level data from 4 multicenter registries. In-hospital major adverse cardiovascular events (MACE) included death, myocardial infarction, stroke, and tamponade. Long-term MACE were defined as the composite of all-cause death, myocardial infarction, and target vessel revascularization. RESULTS: ISR represented 15% of the CTOs (n = 1,755). Patients with ISR CTOs had higher prevalence of diabetes (44% vs. 38%; p \u3c 0.0001) and prior coronary artery bypass graft surgery (27% vs. 24%; p = 0.03). Mean J-CTO (Multicenter CTO Registry in Japan) score was 2.32 ± 1.27 in the ISR group and 2.22 ± 1.27 in the de novo group (p = 0.01). Technical (85% vs. 85%; p = 0.75) and procedural (84% vs. 84%; p = 0.82) success was similar for ISR and de novo CTOs, as was the incidence of in-hospital MACE (1.7% vs. 2.2%; p = 0.25). Antegrade wiring was the most common successful strategy, in 70% of ISR and 60% of de novo CTOs, followed by retrograde crossing (16% vs. 23%) and antegrade dissection and re-entry (15% vs. 16%; p \u3c 0.0001). At 12 months, patients with ISR CTOs had a higher incidence of MACE (hazard ratio: 1.31; 95% confidence intervals: 1.01 to 1.70; p = 0.04). CONCLUSIONS: ISR CTOs represent 15% of all CTO PCIs and can be recanalized with similar success and in-hospital MACE as de novo CTOs

    Global Chronic Total Occlusion Crossing Algorithm: JACC State-of-the-Art Review

    Get PDF
    The authors developed a global chronic total occlusion crossing algorithm following 10 steps: 1) dual angiography; 2) careful angiographic review focusing on proximal cap morphology, occlusion segment, distal vessel quality, and collateral circulation; 3) approaching proximal cap ambiguity using intravascular ultrasound, retrograde, and move-the-cap techniques; 4) approaching poor distal vessel quality using the retrograde approach and bifurcation at the distal cap by use of a dual-lumen catheter and intravascular ultrasound; 5) feasibility of retrograde crossing through grafts and septal and epicardial collateral vessels; 6) antegrade wiring strategies; 7) retrograde approach; 8) changing strategy when failing to achieve progress; 9) considering performing an investment procedure if crossing attempts fail; and 10) stopping when reaching high radiation or contrast dose or in case of long procedural time, occurrence of a serious complication, operator and patient fatigue, or lack of expertise or equipment. This algorithm can improve outcomes and expand discussion, research, and collaboration

    Global Chronic Total Occlusion Crossing Algorithm

    Get PDF
    The authors developed a global chronic total occlusion crossing algorithm following 10 steps: 1) dual angiography; 2) careful angiographic review focusing on proximal cap morphology, occlusion segment, distal vessel quality, and collateral circulation; 3) approaching proximal cap ambiguity using intravascular ultrasound, retrograde, and move-the-cap techniques; 4) approaching poor distal vessel quality using the retrograde approach and bifurcation at the distal cap by use of a dual-lumen catheter and intravascular ultrasound; 5) feasibility of retrograde crossing through grafts and septal and epicardial collateral vessels; 6) antegrade wiring strategies; 7) retrograde approach; 8) changing strategy when failing to achieve progress; 9) considering performing an investment procedure if crossing attempts fail; and 10) stopping when reaching high radiation or contrast dose or in case of long procedural time, occurrence of a serious complication, operator and patient fatigue, or lack of expertise or equipment. This algorithm can improve outcomes and expand discussion, research, and collaboration.info:eu-repo/semantics/publishedVersio

    Shell-and-tube ceramic heat exchangers for high-temperature GTEs applications

    No full text
    Communication to : 11th international heat transfer conference, Kyongju (Korea), August 25-28, 98SIGLEAvailable from INIST (FR), Document Supply Service, under shelf-number : 22419, issue : a.1998 n.182 / INIST-CNRS - Institut de l'Information Scientifique et TechniqueFRFranc

    Upstream flow characterization of the AGATA catalytic combustor by 2 D LDV measurements

    No full text
    Communication to : 7th congress IGTC'99, Kobe (Japan), November 14-19, 1999SIGLEAvailable from INIST (FR), Document Supply Service, under shelf-number : 22419, issue : a.1999 n.200 / INIST-CNRS - Institut de l'Information Scientifique et TechniqueFRFranc

    Facilities for automotive gas turbine ceramic components

    No full text
    Communication to : 42nd ASME gas turbine and aeroengine congress,= Orlando, FL (USA), June 2-5, 1997Available from INIST (FR), Document Supply Service, under shelf-number : 22419, issue : a.1997 n.69 / INIST-CNRS - Institut de l'Information Scientifique et TechniqueSIGLEFRFranc

    Optimization of design of high pressure compact and light-weight liquid heat exchangers

    No full text
    Communication to : 42nd ASME Gas Turbine and Aeroengine congress,= Orlando, FL (USA), June 2-5, 1997SIGLEAvailable from INIST (FR), Document Supply Service, under shelf-number : 22419, issue : a.1997 n.70 / INIST-CNRS - Institut de l'Information Scientifique et TechniqueFRFranc
    corecore