95 research outputs found

    The anticonvulsant effect of citalopram as an indirect evidence of serotonergic impairment in human epileptogenesis

    Get PDF
    AbstractSome evidence would indicate that a serotonergic deficit may be involved in epileptogenesis. A preliminary trial of citalopram, a selective inhibitor of serotonin reuptake, was carried out. Citalopram 20mg/day was given to 11 non-depressed patients with poorly controlled epilepsy as an add on treatment with an open label design for 8–10 months. The median seizure frequency dropped by 55.6% in the whole group, with nine patients improving by at least 50%. No adverse reactions occurred with the exception of mild drowsiness. There were no changes of post-treatment as compared to pre-treatment AED serum concentrations. Although controlled studies are required to confirm the anticonvulsant effect of citalopram, these findings may be regarded as an indirect evidence of serotonergic impairment in human epileptogenesis

    In vitro simulation of dental implant bridges removal: Influence of luting agent and abutments geometry on retrievability

    Get PDF
    Implant fixed dental prostheses are widely used for the treatment of edentulism, often preferred over the screw-retained ones. However, one of the main features of an implant-supported prosthesis is retrievability, which could be necessary in the case of implant complications. In this study, the retrievability of implant-fixed dental prostheses was investigated considering two of the main factors dental practitioners have to deal with: the abutments geometry and the luting agent. Impulsive forces were applied to dental bridge models to simulate crowns’ retrievability in clinical conditions. The number of impulses and the impulsive force delivered during each test were recorded and used as retrievability indexes. One-hundred-and-five tests were conducted on 21 combinations of bridges and luting agents, and a Kruskal-Wallis test was performed on the results. The abutment geometry significantly influenced the number of impulses needed for retrieval (p < 0.05), and a cement-dependent trend was observed as well. On the other hand, the forces measured during tests showed no clear correlation with bridge retrievability. The best retrievability was obtained with long, slightly tapered abutments and a temporary luting agent

    Design and characterization of a minimally invasive bipolar electrode for electroporation

    Get PDF
    Objective: To test a new bipolar electrode for electroporation consisting of a single minimally invasive needle. Methods: A theoretical study was performed by using Comsol Multiphysics® software. The prototypes of electrode have been tested on potatoes and pigs, adopting an irreversible electroporation protocol. Different applied voltages and different geometries of bipolar electrode prototype have been evaluated. Results: Simulations and pre-clinical tests have shown that the volume of ablated area is mainly influenced by applied voltage, while the diameter of the electrode had a lesser impact, making the goal of minimal-invasiveness possible. The conductive pole’s length determined an increase of electroporated volume, while the insulated pole length inversely affects the electroporated volume size and shape; when the insulated pole length decreases, a more regular shape of the electric field is obtained. Moreover, the geometry of the electrode determined a different shape of the electroporated volume. A parenchymal damage in the liver of pigs due to irreversible electroporation protocol was observed. Conclusion: The minimally invasive bipolar electrode is able to treat an electroporated volume of about 10 mm in diameter by using a single-needle electrode. Moreover, the geometry and the electric characteristics can be selected to produce ellipsoidal ablation volumes

    In vitro impact testing to simulate implant-supported prosthesis retrievability in clinical practice: Influence of cement and abutment geometry

    Get PDF
    Cement-retained implant-supported prosthetics are gaining popularity compared to the alternative screw-retained type, a rise that serves to highlight the importance of retrievability. The aim of the present investigation is to determine the influence of luting agent, abutment height and taper angle on the retrievability of abutment-coping cementations. Abutments with different heights and tapers were screwed onto an implant and their cobalt-chrome copings were cemented on the abutments using three different luting agents. The removals were performed by means of Coronaflex®. The number of impulses and the forces were recorded and analyzed with a Kruskal-Wallis test. Harvard cement needed the highest number of impulses for retrieval, followed by Telio CS and Temp Bond. However, abutment height and taper showed a greater influence on the cap's retrievability (p < 0.05). Long and tapered abutments provided the highest percentage of good retrievability. The influence of the luting agent and the abutment geometry on the cap's retrieval performed by Coronaflex® reflects data from literature about the influence of the same factor on the maximum force reached during uniaxial tensile tests. The impulse force was slightly affected by the same factors

    A low-cost scalable 3D-printed sample-holder for agitation-based decellularization of biological tissues

    Get PDF
    Decellularized extracellular matrix is one of the most promising biological scaffold supporting in vitro tissue growth and in vivo tissue regeneration in both preclinical research and clinical practice. In case of thick tissues or even organs, conventional static decellularization methods based on chemical or enzymatic treatments are not effective in removing the native cellular material without affecting the extracellular matrix. To overcome this limitation, dynamic decellularization methods, mostly based on perfusion and agitation, have been proposed. In this study, we developed a low-cost scalable 3D-printed sample-holder for agitation-based decellularization purposes, designed for treating multiple specimens simultaneously and for improving efficiency, homogeneity and reproducibility of the decellularization treatment with respect to conventional agitation-based approaches. In detail, the proposed sample-holder is able to house up to four specimens and, immersed in the decellularizing solution within a beaker placed on a magnetic stirrer, to expose them to convective flow, enhancing the solution transport through the specimens while protecting them. Computational fluid dynamics analyses were performed to investigate the fluid phenomena establishing within the beaker and to support the sample-holder design. Exploratory biological tests performed on human skin specimens demonstrated that the sample-holder reduces process duration and increases treatment homogeneity and reproducibility

    Differential thermography for experimental, full-field stress analysis of hip arthroplasty

    No full text
    A hip prosthesis implant produces a significant deviation in the stress pattern compared with the physiologic condition. In this work, the stress patterns are evaluated experimentally on synthetic femora, by means of thermoelastic stress analysis. Two factors have been considered: stem implantation and head offset. Stress maps were obtained using differential thermography and correlated to these factors. Thermoelastic stress maps have demonstrated to be sensitive to the implant and the head offset. In detail, the standard deviation of stresses can reduce from -5% to -50% (with reference to the physiologic one), depending on stem design; peak stresses change their position or disappear for different implant position or press-fitting, the sensitivity of average stresses to the offset is at least equal to 0.07MPa/mm. On the whole, a methodology was developed, allowing the experimental evaluation and comparison of the stress distributions produced by different implant

    What's in a Name? Shifting Identities of Traditional Organized Crime in Canada in the Transnational Fight against the Calabrian ‘Ndrangheta

    Get PDF
    The Italian antimafia authorities have warned Canadian law enforcement about the risks and the growing concerns for the infiltration of clans of the Calabrian mafia, known as ‘ndrangheta, in Eastern Canada. The alarm linked to the rise of the ‘ndrangheta challenges the paradigms of traditional organized crime in Canada, because the ‘ndrangheta is presented as traditional but also innovative and more pervasive than other mafia-type groups. Through access to confidential investigations and interviews to key specialist law enforcement teams in Toronto and Montreal, this article investigates today's institutional perception of mafia – the ‘ndrangheta in particular – in Canada when compared to Italian conceptualizations. I will argue that the changes in narratives in Canada can be read in relation to changes in the Italian identity in the country, moving towards regionalization and specialist knowledge of ethnic differences

    Non-convulsive status epilepticus * Author's reply

    No full text
    • …
    corecore