Prediction of Opioid-Induced Respiratory Depression on Inpatient Wards Using Continuous Capnography and Oximetry: An International Prospective, Observational Trial
Background: Opioid-related adverse events are a serious problem in hospitalized patients. Little is known about patients who are likely to experience opioid-induced respiratory depression events on the general care floor and may benefit from improved monitoring and early intervention. The trial objective was to derive and validate a risk prediction tool for respiratory depression in patients receiving opioids, as detected by continuous pulse oximetry and capnography monitoring.
Methods: PRediction of Opioid-induced respiratory Depression In patients monitored by capnoGraphY (PRODIGY) was a prospective, observational trial of blinded continuous capnography and oximetry conducted at 16 sites in the United States, Europe, and Asia. Vital signs were intermittently monitored per standard of care. A total of 1335 patients receiving parenteral opioids and continuously monitored on the general care floor were included in the analysis. A respiratory depression episode was defined as respiratory rate ≤5 breaths/min (bpm), oxygen saturation ≤85%, or end-tidal carbon dioxide ≤15 or ≥60 mm Hg for ≥3 minutes; apnea episode lasting >30 seconds; or any respiratory opioid-related adverse event. A risk prediction tool was derived using a multivariable logistic regression model of 46 a priori defined risk factors with stepwise selection and was internally validated by bootstrapping.
Results: One or more respiratory depression episodes were detected in 614 (46%) of 1335 general care floor patients (43% male; mean age, 58 ± 14 years) continuously monitored for a median of 24 hours (interquartile range [IQR], 17-26). A multivariable respiratory depression prediction model with area under the curve of 0.740 was developed using 5 independent variables: age ≥60 (in decades), sex, opioid naivety, sleep disorders, and chronic heart failure. The PRODIGY risk prediction tool showed significant separation between patients with and without respiratory depression (P < .001) and an odds ratio of 6.07 (95% confidence interval [CI], 4.44-8.30; P < .001) between the high- and low-risk groups. Compared to patients without respiratory depression episodes, mean hospital length of stay was 3 days longer in patients with ≥1 respiratory depression episode (10.5 ± 10.8 vs 7.7 ± 7.8 days; P < .0001) identified using continuous oximetry and capnography monitoring.
Conclusions: A PRODIGY risk prediction model, derived from continuous oximetry and capnography, accurately predicts respiratory depression episodes in patients receiving opioids on the general care floor. Implementation of the PRODIGY score to determine the need for continuous monitoring may be a first step to reduce the incidence and consequences of respiratory compromise in patients receiving opioids on the general care floor
Prediction of Opioid-Induced Respiratory Depression on Inpatient Wards Using Continuous Capnography and Oximetry: An International Prospective, Observational Trial.
BACKGROUND: Opioid-related adverse events are a serious problem in hospitalized patients. Little is known about patients who are likely to experience opioid-induced respiratory depression events on the general care floor and may benefit from improved monitoring and early intervention. The trial objective was to derive and validate a risk prediction tool for respiratory depression in patients receiving opioids, as detected by continuous pulse oximetry and capnography monitoring.
METHODS: PRediction of Opioid-induced respiratory Depression In patients monitored by capnoGraphY (PRODIGY) was a prospective, observational trial of blinded continuous capnography and oximetry conducted at 16 sites in the United States, Europe, and Asia. Vital signs were intermittently monitored per standard of care. A total of 1335 patients receiving parenteral opioids and continuously monitored on the general care floor were included in the analysis. A respiratory depression episode was defined as respiratory rate ≤5 breaths/min (bpm), oxygen saturation ≤85%, or end-tidal carbon dioxide ≤15 or ≥60 mm Hg for ≥3 minutes; apnea episode lasting \u3e30 seconds; or any respiratory opioid-related adverse event. A risk prediction tool was derived using a multivariable logistic regression model of 46 a priori defined risk factors with stepwise selection and was internally validated by bootstrapping.
RESULTS: One or more respiratory depression episodes were detected in 614 (46%) of 1335 general care floor patients (43% male; mean age, 58 ± 14 years) continuously monitored for a median of 24 hours (interquartile range [IQR], 17-26). A multivariable respiratory depression prediction model with area under the curve of 0.740 was developed using 5 independent variables: age ≥60 (in decades), sex, opioid naivety, sleep disorders, and chronic heart failure. The PRODIGY risk prediction tool showed significant separation between patients with and without respiratory depression (P \u3c .001) and an odds ratio of 6.07 (95% confidence interval [CI], 4.44-8.30; P \u3c .001) between the high- and low-risk groups. Compared to patients without respiratory depression episodes, mean hospital length of stay was 3 days longer in patients with ≥1 respiratory depression episode (10.5 ± 10.8 vs 7.7 ± 7.8 days; P \u3c .0001) identified using continuous oximetry and capnography monitoring.
CONCLUSIONS: A PRODIGY risk prediction model, derived from continuous oximetry and capnography, accurately predicts respiratory depression episodes in patients receiving opioids on the general care floor. Implementation of the PRODIGY score to determine the need for continuous monitoring may be a first step to reduce the incidence and consequences of respiratory compromise in patients receiving opioids on the general care floor
Recommended from our members
Validation of the STOP-Bang Questionnaire as a Screening Tool for Obstructive Sleep Apnea among Different Populations: A Systematic Review and Meta-Analysis
Background: Diagnosing obstructive sleep apnea (OSA) is clinically relevant because untreated OSA has been associated with increased morbidity and mortality. The STOP-Bang questionnaire is a validated screening tool for OSA. We conducted a systematic review and meta-analysis to determine the effectiveness of STOP-Bang for screening patients suspected of having OSA and to predict its accuracy in determining the severity of OSA in the different populations. Methods: A search of the literature databases was performed. Inclusion criteria were: 1) Studies that used STOP-Bang questionnaire as a screening tool for OSA in adult subjects (>18 years); 2) The accuracy of the STOP-Bang questionnaire was validated by polysomnography—the gold standard for diagnosing OSA; 3) OSA was clearly defined as apnea/hypopnea index (AHI) or respiratory disturbance index (RDI) ≥ 5; 4) Publications in the English language. The quality of the studies were explicitly described and coded according to the Cochrane Methods group on the screening and diagnostic tests. Results: Seventeen studies including 9,206 patients met criteria for the systematic review. In the sleep clinic population, the sensitivity was 90%, 94% and 96% to detect any OSA (AHI ≥ 5), moderate-to-severe OSA (AHI ≥15), and severe OSA (AHI ≥30) respectively. The corresponding NPV was 46%, 75% and 90%. A similar trend was found in the surgical population. In the sleep clinic population, the probability of severe OSA with a STOP-Bang score of 3 was 25%. With a stepwise increase of the STOP-Bang score to 4, 5, 6 and 7/8, the probability rose proportionally to 35%, 45%, 55% and 75%, respectively. In the surgical population, the probability of severe OSA with a STOP-Bang score of 3 was 15%. With a stepwise increase of the STOP-Bang score to 4, 5, 6 and 7/8, the probability increased to 25%, 35%, 45% and 65%, respectively. Conclusion: This meta-analysis confirms the high performance of the STOP-Bang questionnaire in the sleep clinic and surgical population for screening of OSA. The higher the STOP-Bang score, the greater is the probability of moderate-to-severe OSA.</p
Perioperative adherence to continuous positive airway pressure and its effect on postoperative nocturnal hypoxemia in obstructive sleep apnea patients: a prospective cohort study
Abstract
Background
Although continuous positive airway pressure (CPAP) is the first line treatment for obstructive sleep apnea (OSA) patients, the perioperative adherence rate is unclear. The objective of this study was to determine the perioperative adherence rate of patients with OSA with a CPAP prescription and the effect of adherence on nocturnal oxygen saturation.
Methods
This prospective cohort study included adult surgical patients with a diagnosis of OSA with CPAP prescription undergoing elective non-cardiac surgery. Patients were divided into CPAP adherent and non-adherent groups based on duration of usage (≥ 4 h/night). Overnight oximetry was performed preoperatively and on postoperative night 1 and 2 (N1, N2). The primary outcome was adherence rate and the secondary outcome was nocturnal oxygen saturation.
Results
One hundred and thirty-two patients completed the study. CPAP adherence was 61% preoperatively, 58% on postoperative N1, and 59% on N2. Forty-nine percent were consistently CPAP adherent pre- and postoperatively. Using a linear fixed effects regression, oxygen desaturation index (ODI) was significantly improved by CPAP adherence (p = 0.0011). The interaction term CPAP x N1 was significant (p = 0.0015), suggesting that the effect of CPAP adherence varied on N1 vs preoperatively. There was no benefit of CPAP adherence on postoperative mean SpO2, minimum SpO2, and percentage of sleep duration with SpO2 < 90%. Use of supplemental oxygen therapy was much lower in the CPAP adherent group vs non-adherent group (9.8% vs 46.5%, p <  0.001).
Conclusions
Among patients with a preoperative CPAP prescription, approximately 50% were consistently adherent. CPAP adherence was associated with improved preoperative ODI and the benefit was maintained on N1. These modest effects may be underestimated by a higher severity of OSA in the CPAP adherent group and a higher rate of oxygen supplementation in the non-adherent group.
Trial registration
ClinicalTrials.Gov registry (
NCT02796846
)
Psychometric Performance and Responsiveness of the Functional Outcomes of Sleep Questionnaire and Sleep Apnea Quality of Life Index in a Randomized Trial: The HomePAP Study
Study objectivesMeasures of health-related quality of life (HRQL) specific for sleep disorders have had limited psychometric evaluation in the context of randomized controlled trials (RCTs). We investigated the psychometric properties of the Functional Outcomes of Sleep Questionnaire (FOSQ) and Sleep Apnea Quality of Life Instrument (SAQLI). We evaluated the FOSQ and SAQLI construct and criterion validity, determined a minimally important difference, and assessed for associations of responsiveness to baseline subject characteristics and continuous positive airway pressure (CPAP) adherence in a RCT population.DesignSecondary analysis of data collected in a multisite RCT of home versus laboratory-based diagnosis and treatment of obstructive sleep apnea (HomePAP trial).ParticipantsIndividuals enrolled in the HomePAP trial (n = 335).InterventionsN/A.Measurement and resultsThe FOSQ and SAQLI subscores demonstrated high reliability and criterion validity, correlating with Medical Outcomes Study 36-Item Short Form Survey domains. Correlations were weaker with the Epworth Sleepiness Scale (ESS). Both the FOSQ and SAQLI scores improved after 3 mo with CPAP therapy. Averaging 4 h or more of CPAP use was associated with an increase in the FOSQ beyond the minimally important difference. Baseline depressive symptoms and sleepiness predicted FOSQ and SAQLI responsiveness; demographic, objective obstructive sleep apnea (OSA) severity and sleep habits were not predictive in linear regression.ConclusionsThe FOSQ and SAQLI are responsive to CPAP intervention, with the FOSQ being more sensitive to differences in CPAP adherence than the SAQLI. These instruments provide unique information about health outcomes beyond that provided by changes in physiological measures of OSA severity (apnea-hypopnea index).Clinical trial informationPortable Monitoring for Diagnosis and Management of Sleep Apnea (HomePAP) URL: http://clinicaltrials.gov/show/NCT00642486. NIH clinical trials registry number: NCT00642486