35 research outputs found

    Prediction of Opioid-Induced Respiratory Depression on Inpatient Wards Using Continuous Capnography and Oximetry: An International Prospective, Observational Trial

    Get PDF
    Background: Opioid-related adverse events are a serious problem in hospitalized patients. Little is known about patients who are likely to experience opioid-induced respiratory depression events on the general care floor and may benefit from improved monitoring and early intervention. The trial objective was to derive and validate a risk prediction tool for respiratory depression in patients receiving opioids, as detected by continuous pulse oximetry and capnography monitoring. Methods: PRediction of Opioid-induced respiratory Depression In patients monitored by capnoGraphY (PRODIGY) was a prospective, observational trial of blinded continuous capnography and oximetry conducted at 16 sites in the United States, Europe, and Asia. Vital signs were intermittently monitored per standard of care. A total of 1335 patients receiving parenteral opioids and continuously monitored on the general care floor were included in the analysis. A respiratory depression episode was defined as respiratory rate ≤5 breaths/min (bpm), oxygen saturation ≤85%, or end-tidal carbon dioxide ≤15 or ≥60 mm Hg for ≥3 minutes; apnea episode lasting >30 seconds; or any respiratory opioid-related adverse event. A risk prediction tool was derived using a multivariable logistic regression model of 46 a priori defined risk factors with stepwise selection and was internally validated by bootstrapping. Results: One or more respiratory depression episodes were detected in 614 (46%) of 1335 general care floor patients (43% male; mean age, 58 ± 14 years) continuously monitored for a median of 24 hours (interquartile range [IQR], 17-26). A multivariable respiratory depression prediction model with area under the curve of 0.740 was developed using 5 independent variables: age ≥60 (in decades), sex, opioid naivety, sleep disorders, and chronic heart failure. The PRODIGY risk prediction tool showed significant separation between patients with and without respiratory depression (P < .001) and an odds ratio of 6.07 (95% confidence interval [CI], 4.44-8.30; P < .001) between the high- and low-risk groups. Compared to patients without respiratory depression episodes, mean hospital length of stay was 3 days longer in patients with ≥1 respiratory depression episode (10.5 ± 10.8 vs 7.7 ± 7.8 days; P < .0001) identified using continuous oximetry and capnography monitoring. Conclusions: A PRODIGY risk prediction model, derived from continuous oximetry and capnography, accurately predicts respiratory depression episodes in patients receiving opioids on the general care floor. Implementation of the PRODIGY score to determine the need for continuous monitoring may be a first step to reduce the incidence and consequences of respiratory compromise in patients receiving opioids on the general care floor

    Prediction of Opioid-Induced Respiratory Depression on Inpatient Wards Using Continuous Capnography and Oximetry: An International Prospective, Observational Trial.

    Get PDF
    BACKGROUND: Opioid-related adverse events are a serious problem in hospitalized patients. Little is known about patients who are likely to experience opioid-induced respiratory depression events on the general care floor and may benefit from improved monitoring and early intervention. The trial objective was to derive and validate a risk prediction tool for respiratory depression in patients receiving opioids, as detected by continuous pulse oximetry and capnography monitoring. METHODS: PRediction of Opioid-induced respiratory Depression In patients monitored by capnoGraphY (PRODIGY) was a prospective, observational trial of blinded continuous capnography and oximetry conducted at 16 sites in the United States, Europe, and Asia. Vital signs were intermittently monitored per standard of care. A total of 1335 patients receiving parenteral opioids and continuously monitored on the general care floor were included in the analysis. A respiratory depression episode was defined as respiratory rate ≤5 breaths/min (bpm), oxygen saturation ≤85%, or end-tidal carbon dioxide ≤15 or ≥60 mm Hg for ≥3 minutes; apnea episode lasting \u3e30 seconds; or any respiratory opioid-related adverse event. A risk prediction tool was derived using a multivariable logistic regression model of 46 a priori defined risk factors with stepwise selection and was internally validated by bootstrapping. RESULTS: One or more respiratory depression episodes were detected in 614 (46%) of 1335 general care floor patients (43% male; mean age, 58 ± 14 years) continuously monitored for a median of 24 hours (interquartile range [IQR], 17-26). A multivariable respiratory depression prediction model with area under the curve of 0.740 was developed using 5 independent variables: age ≥60 (in decades), sex, opioid naivety, sleep disorders, and chronic heart failure. The PRODIGY risk prediction tool showed significant separation between patients with and without respiratory depression (P \u3c .001) and an odds ratio of 6.07 (95% confidence interval [CI], 4.44-8.30; P \u3c .001) between the high- and low-risk groups. Compared to patients without respiratory depression episodes, mean hospital length of stay was 3 days longer in patients with ≥1 respiratory depression episode (10.5 ± 10.8 vs 7.7 ± 7.8 days; P \u3c .0001) identified using continuous oximetry and capnography monitoring. CONCLUSIONS: A PRODIGY risk prediction model, derived from continuous oximetry and capnography, accurately predicts respiratory depression episodes in patients receiving opioids on the general care floor. Implementation of the PRODIGY score to determine the need for continuous monitoring may be a first step to reduce the incidence and consequences of respiratory compromise in patients receiving opioids on the general care floor

    Meet Our Editorial Board Member

    No full text

    Perioperative adherence to continuous positive airway pressure and its effect on postoperative nocturnal hypoxemia in obstructive sleep apnea patients: a prospective cohort study

    No full text
    Abstract Background Although continuous positive airway pressure (CPAP) is the first line treatment for obstructive sleep apnea (OSA) patients, the perioperative adherence rate is unclear. The objective of this study was to determine the perioperative adherence rate of patients with OSA with a CPAP prescription and the effect of adherence on nocturnal oxygen saturation. Methods This prospective cohort study included adult surgical patients with a diagnosis of OSA with CPAP prescription undergoing elective non-cardiac surgery. Patients were divided into CPAP adherent and non-adherent groups based on duration of usage (≥ 4 h/night). Overnight oximetry was performed preoperatively and on postoperative night 1 and 2 (N1, N2). The primary outcome was adherence rate and the secondary outcome was nocturnal oxygen saturation. Results One hundred and thirty-two patients completed the study. CPAP adherence was 61% preoperatively, 58% on postoperative N1, and 59% on N2. Forty-nine percent were consistently CPAP adherent pre- and postoperatively. Using a linear fixed effects regression, oxygen desaturation index (ODI) was significantly improved by CPAP adherence (p = 0.0011). The interaction term CPAP x N1 was significant (p = 0.0015), suggesting that the effect of CPAP adherence varied on N1 vs preoperatively. There was no benefit of CPAP adherence on postoperative mean SpO2, minimum SpO2, and percentage of sleep duration with SpO2 < 90%. Use of supplemental oxygen therapy was much lower in the CPAP adherent group vs non-adherent group (9.8% vs 46.5%, p <  0.001). Conclusions Among patients with a preoperative CPAP prescription, approximately 50% were consistently adherent. CPAP adherence was associated with improved preoperative ODI and the benefit was maintained on N1. These modest effects may be underestimated by a higher severity of OSA in the CPAP adherent group and a higher rate of oxygen supplementation in the non-adherent group. Trial registration ClinicalTrials.Gov registry ( NCT02796846 )

    Psychometric Performance and Responsiveness of the Functional Outcomes of Sleep Questionnaire and Sleep Apnea Quality of Life Index in a Randomized Trial: The HomePAP Study

    No full text
    Study objectivesMeasures of health-related quality of life (HRQL) specific for sleep disorders have had limited psychometric evaluation in the context of randomized controlled trials (RCTs). We investigated the psychometric properties of the Functional Outcomes of Sleep Questionnaire (FOSQ) and Sleep Apnea Quality of Life Instrument (SAQLI). We evaluated the FOSQ and SAQLI construct and criterion validity, determined a minimally important difference, and assessed for associations of responsiveness to baseline subject characteristics and continuous positive airway pressure (CPAP) adherence in a RCT population.DesignSecondary analysis of data collected in a multisite RCT of home versus laboratory-based diagnosis and treatment of obstructive sleep apnea (HomePAP trial).ParticipantsIndividuals enrolled in the HomePAP trial (n = 335).InterventionsN/A.Measurement and resultsThe FOSQ and SAQLI subscores demonstrated high reliability and criterion validity, correlating with Medical Outcomes Study 36-Item Short Form Survey domains. Correlations were weaker with the Epworth Sleepiness Scale (ESS). Both the FOSQ and SAQLI scores improved after 3 mo with CPAP therapy. Averaging 4 h or more of CPAP use was associated with an increase in the FOSQ beyond the minimally important difference. Baseline depressive symptoms and sleepiness predicted FOSQ and SAQLI responsiveness; demographic, objective obstructive sleep apnea (OSA) severity and sleep habits were not predictive in linear regression.ConclusionsThe FOSQ and SAQLI are responsive to CPAP intervention, with the FOSQ being more sensitive to differences in CPAP adherence than the SAQLI. These instruments provide unique information about health outcomes beyond that provided by changes in physiological measures of OSA severity (apnea-hypopnea index).Clinical trial informationPortable Monitoring for Diagnosis and Management of Sleep Apnea (HomePAP) URL: http://clinicaltrials.gov/show/NCT00642486. NIH clinical trials registry number: NCT00642486
    corecore