6 research outputs found

    Preoperative plasma growth-differentiation factor-15 for prediction of acute kidney injury in patients undergoing cardiac surgery

    Get PDF
    Covariate plot of the predictions from the random forest model. Four variables are displayed. Within each box, the x-axis denotes plasma creatinine (ĂŽĹşmol/l), the y-axis the probability of developing cardiac-surgery-associated acute kidney injury (CSA-AKI). Within each column of plots, the additive Euroscore increases from bottom to top (legend, right). Within each row of plots the growth-differentiation factor-15 (GDF-15) levels increase from left to right. Significant non-linear interaction takes place between GDF-15 and creatinine. Within each additive Euroscore category (row of plots), increases in GDF-15 (plots more to the right within each row) increase the probability of developing CSA-AKI. However, this effect is more prominent in patients with normal creatinine (x-axis label of each plot). (TIFF 3197 kb

    Improving Systems Dynamics by Means of Advanced Signal Processing -Mathematical, Laboratorial and Clinical Evaluation of Propofol Monitoring in Breathing Gas

    Get PDF
    Abstract: Electrochemical sensors are used in various gas measurement applications and are available for different gases. Depending on the application, the sensor might need to be installed far away from the actual measurement site, requiring the use of long sampling lines. Examples are portable gas measurement devices in which remote locations like tanks and chemical reactors need to be monitored. But also medical applications, where the sensors cannot be positioned in close vicinity to the patient, are common like, e.g., the side-stream measurement of breathing gas. Due to the characteristics of electrochemical sensors and to the adsorption and desorption behavior of sampling lines for different gases, the electrical sensor signal may indicate long response times. In this paper, we propose an on-line signal processing algorithm which is capable to significantly improve the performance. After characterizing the dynamic behavior of the sensor system, a properly designed deconvolution filter is used to reduce response time and signal noise. Within this article, we also provide an http://www.sensorsportal.com/HTML/DIGEST/P_2747.htm Sensors & Transducers, Vol. 193, Issue 10, October 2015, pp. 145-153 146 example of this algorithm for a novel electrochemical sensor for the measurement of the anesthetic agent propofol in exhaled air. For this application, the acceleration is prerequisite for the measurement chain to be of practical use in a clinical setting. Our goals, to establish measurement dynamics to record the physiologic parameter and to reduce non-physiological disturbances, were achieved with additional reserves. This article is based o

    Improving Systems Dynamics by Means of Advanced Signal Processing – Mathematical, Laboratorial and Clinical Evaluation of Propofol Monitoring in Breathing Gas

    No full text
    Electrochemical sensors are used in various gas measurement applications and are available for different gases. Depending on the application, the sensor might need to be installed far away from the actual measurement site, requiring the use of long sampling lines. Examples are portable gas measurement devices in which remote locations like tanks and chemical reactors need to be monitored. But also medical applications, where the sensors cannot be positioned in close vicinity to the patient, are common like, e.g., the side-stream measurement of breathing gas. Due to the characteristics of electrochemical sensors and to the adsorption and desorption behavior of sampling lines for different gases, the electrical sensor signal may indicate long response times. In this paper, we propose an on-line signal processing algorithm which is capable to significantly improve the performance. After characterizing the dynamic behavior of the sensor system, a properly designed deconvolution filter is used to reduce response time and signal noise. Within this article, we also provide an example of this algorithm for a novel electrochemical sensor for the measurement of the anesthetic agent propofol in exhaled air. For this application, the acceleration is prerequisite for the measurement chain to be of practical use in a clinical setting. Our goals, to establish measurement dynamics to record the physiologic parameter and to reduce non-physiological disturbances, were achieved with additional reserves. This article is based on 1 and is extended by original clinical data. As an example, we present propofol monitoring in breath of one patient in order to demonstrate the performance of the introduced algorithm in a real clinical application. We proved that the electrochemical sensor, associated with the provided algorithm, is capable for real-time monitoring in a clinical setting
    corecore