    Hard x ray spectroscopy and imaging by a reflection zone plate in the presence of astigmatism

    Get PDF
    The feasibility of an off axis x ray reflection zone plate to perform wavelength dispersive spectroscopy, on axis point focusing, and two dimensional imaging is demonstrated by means of one and the same diffractive optical element DOE at a synchrotron radiation facility. The resolving power varies between 30 and 400 in the range of 7.6 keV to 9.0 keV, with its maximum at the design energy of 8.3 keV. This result is verified using an adjustable entrance slit, by which horizontal H and vertical V focusing to 0.85 amp; 956;m H and 1.29 amp; 956;m V is obtained near the sagittal focal plane of the astigmatic configuration. An angular and axial scan proves an accessible field of view of at least 0.6 arcmin 0.8 arcmin and a focal depth of plus minus 0.86 mm. Supported by the grating efficiency of around 17.5 and a very short pulse elongation, future precision x ray fluorescence and absorption studies of transition metals at their K edge on an ultrashort timescale could benefit from our finding

    Performance of cryogenically cooled, high‐heat‐load silicon crystal monochromators with porous media augmentation

    Get PDF
    The performance of two Si crystal x-ray monochromators internally cooled with liquid nitrogen was tested on the F2-wiggler beamline at the Cornell High Energy Synchrotron Source (CHESS). Both crystals were (111)-oriented blocks of rectangular cross section having identical dimensions. Seven 6.4-mm-diameter coolant channels were drilled through the crystals along the beam direction. In one of the crystals, porous Cu mesh inserts were bonded into the channels to enhance the heat transfer. The channels of the second crystal were left as drilled. Symmetric, double-crystal rocking curves were recorded simultaneously for both the first and third order reflections at 8 and 24 keV. The power load on the cooled crystal was adjusted by varying the horizontal beam size using slits. The measured Si(333) rocking curve of the unenhanced crystal at 24 keV at low power was 1.9 arcsec FWHM. The theoretical width is 0.63 arcsec. The difference is due to residual fabrication and mounting strain. For a maximum incident power of 601 W and an average power density of about 10 W/MM{sup 2}, the rocking curve was 2.7 arcsec. The rocking curve for the enhanced crystal at low power was 2.4 arcsec. At a maximum incident power of 1803 W and an average power density of about 19 W/mm{sup 2} the rocking curve width was 2.2 arcsec FWHM. The use of porous mesh augmentation is a simple, but very effective, means to improve the performance of cryogenically cooled Si monochromators exposed to high power x-ray beams

    Liquid‐metal‐cooled curved‐crystal monochromator for Advanced Photon Source bending‐magnet beamline 1‐BM

    Get PDF
    The authors describe a horizontally focusing curved-crystal monochromator that invokes a 4-point bending scheme and a liquid-metal cooling bath. The device has been designed for dispersive diffraction and spectroscopy in the 5--20 keV range, with a predicted focal spot size of {le} 100 {micro}m. To minimize thermal distortions and thermal equilibration time, the 355 x 32 x 0.8 mm crystal will be nearly half submerged in a bath of Ga-In-Sn-Zn alloy. The liquid metal thermally couples the crystal to the water-cooled Cu frame, while permitting the required crystal bending. Calculated thermal profiles and anticipated focusing properties are discussed
    corecore