1,024 research outputs found
99mTc-MIBI Lung Scintigraphy in the Assessment of Pulmonary Involvement in Interstitial Lung Disease and Its Comparison With Pulmonary Function Tests and High-Resolution Computed Tomography: A Preliminary Study
The differentiation of active inflammatory processes from an inactive form of the disease is of great value in the management of interstitial lung disease (ILD). The aim of this investigation was to assess the efficacy of 99mTc-methoxy-isobutyl-isonitrile (99mTc-MIBI) scans in distinguishing the severity of the disease compared to radiological and clinical parameters.In total, 19 known cases of ILD were included in this study and were followed up for 1 year. Five patients without lung disease were considered as the control group. The patients underwent pulmonary function tests (PFTs) and high-resolution computed tomography scans, followed by 99mTc-MIBI scanning. The 99mTc-MIBI scans were analyzed either qualitatively (subjectively) or semiquantitatively.All 19 ILD patients demonstrated a strong increase in 99mTc-MIBI uptake in the lungs compared to the control group. The 99mTc-MIBI scan scores were higher in the patient group in both the early phase (0.240.19-0.31 vs 0.110.10-0.15, P 0.14). The 99mTc-MIBI scan scores were not significantly correlated with the PFT findings (P > 0.05). In total, 5 patients died and 14 patients were still alive over the 1-year follow-up period. There was also a significant difference between the uptake intensity of 99mTc-MIBI and the outcome in the early phase (dead: 0.320.29-0.43 vs alive: 0.210.18-0.24, P < 0.05) and delayed phase (dead: 0.270.22-0.28 vs alive: 0.100.07-0.19, P < 0.05).The washout rate was ~40 min starting from 20 min up to 60 min and this rate was significantly different in our 2 study groups (ILD: 46.6115.61-50.39 vs NL: 70.9127.09-116.36, P = 0.04).The present study demonstrated that 99mTc-MIBI lung scans might distinguish the severity of pulmonary involvement in early views, which were well correlated with HRCT findings. These results also revealed that 99mTc-MIBI lung scans might be used as a complement to other diagnostic and clinical examinations in terms of functional information in ILD; however, further investigations are strongly required
Recommended from our members
Development and Validation of a Thermo-Economic Model for Design Optimisation and Off-Design Performance Evaluation of a Pure Solar Microturbine
The aim of this paper is to present a thermo-economic model of a microturbine for solar dish applications, which demonstrates the applicability and accuracy of the model for off-design performance evaluation and techno-economic optimisation purposes. The model is built using an object-oriented programming approach. Each component is represented using a class made of functions that perform a one-dimensional physical design, off-design performance analysis and the component cost evaluation. Compressor, recuperator, receiver and turbine models are presented and validated against experimental data available in literature, and each demonstrated good accuracy for a wide range of operating conditions. A 7-kWe microturbine and solar irradiation data available for Rome between 2004 and 2005 were considered as a case study, and the thermo-economic analysis of the plant was performed to estimate the levelised cost of electricity based on the annual performance of the plant. The overall energy produced by the plant is 10,682 kWh, the capital cost has been estimated to be EUR 27,051 and, consequently, the specific cost of the plant, defined as the ratio between the cost of components and output power in design condition, has been estimated to be around EUR 3980/kWe. Results from the levelised cost of electricity (LCOE) analysis demonstrate a levelised cost of electricity of EUR 22.81/kWh considering a plant lifetime of 25 years. The results of the present case study have been compared with the results from IPSEpro 7 where the same component characteristic maps and operational strategy were considered. This comparison was aimed to verify the component matching procedure adopted for the present model. A plant sizing optimisation was then performed to determine the plant size which minimises the levelised cost of electricity. The design space of the optimisation variable is limited to the values 0.07–0.16 kg/s. Results of the optimisation demonstrate a minimum LCOE of 21.5 [EUR/kWh] for a design point mass flow rate of about 0.11 kg/s. This corresponds to an overall cost of the plant of around EUR 32,600, with a dish diameter of 9.4 m and an annual electricity production of 13,700 [kWh]
Comparison of three with six regions of interest analyses in patients with idiopathic constipation undertaking colon transit scintigraphy using 67Ga-citrate
OBJECTIVE AND INTRODUCTION: Preparation of data from 6 geometric regions of interest in the colon is time consuming, and can become impractical in the environment of busy Nuclear Medicine Departments. Therefore, we have investigated and demonstrated an alternative method for obtaining the same diagnostic information from an analysis of patients with idiopathic constipation who underwent colon transit scintigraphy using 67Ga-citrate. Data analysis methods using three regions of interest are compared to the results obtained using the more time consuming 6 regions of interest method to analyze the data. MATERIALS AND METHODS: In this study, we report our results of the comparative reanalysis of data obtained by more traditional methods. We compare 3 regions of interest (ROI) which were taken from areas including the right colon, left colon and the rectosigmoid colon, with original work using our alternative 6 (ROI) diagnostic methodology. In addition, the proximal colonic emptying (PCE) was determined at 24 hr post ingestion among members of 3 identified subject groups. RESULTS: The distribution of activity as the ingested 67Ga-citrate passes through the colon constitutes an activity profile. The mean activity position in the colon can be determined from subsequent radiographic images and from this the mean clearance time can be calculated. In quantitative assessment, this represents the time at which half of activity was eliminated from colon (mean half clearance time - MCT) which did not appear different in the reanalysis. There is no significant difference in the current study in GMC 24h, GMC 48h and GMC 72h between two groups using the Man Whitney u test (p > 0.05), while in the previous work the results were statistically significant for the two later time periods GMC (GMC 48h and GMC 72h) (p = 0.016 and p = 0.027 respectively). The PCE in the group 1 was = 2.50 (0.37); group 2, 1.57 (0.47) and group 3, 2.97. The PCE was not different between the two groups (p = 0.21). CONCLUSIONS: This investigation demonstrated that the radionuclide colon transit study using 67Ga-citrate is a safe, physiologic, and quantitative method for evaluating the transit of fecal material from cecum to rectum. Although, the visual assessment of diagnosis of the subjects in the two analyses is the same, it was not completely supported by quantitative measurements. Therefore, further studies need to be done
Radiation exposure from diagnostic nuclear medicine examinations in golestan province
Introduction: The aim of present study was to estimate effective dose from most common procedures performed in nuclear medicine departments of Golestan province. Methods: Data of nuclear medicine procedures performed in 2 nuclear medicine departments in Golestan province were collected during 4 years. Effective dose, collective effective dose and effective dose per examination were calculated using standard dosimetry tables. Results: Based on the data of this study, results of 10437 nuclear medicine procedures performed during 4 years have lead to 3.97 mSv as average effective dose per examination and 10.37 human-Sv as mean collective effective dose. It was also revealed that Tc-99m was the main source of effective dose (98.3%), bone scan was the most common procedure (25.9%) and cardiac scan (MIBI-rest) has the highest collective effective dose (33.5%) during 4 years. Conclusion: Beside the cardiac scan which was the most common nuclear medicine procedure and the main contributor of effective dose in patients, due to geographical condition of the northeast of Iran, bone scan was the highest performed nuclear medicine examination in the Golestan province
- …