7 research outputs found

    Co-registration and quantification of OPT and MR images of pancreatic islets

    No full text
    Yin T., Rangarajan J.R., Ketkar-Atre A., Eriksson A.U., Ahlgreen U., Maes F., Himmelreich U., ''Co-registration and quantification of OPT and MR images of pancreatic islets'', First Belgian molecular imaging congress - BMIC-2013, March 21, 2013, Leuven, Belgium.status: publishe

    Co-registration and quantification of OPT and MR images of pancreatic islets

    No full text
    Yin T., Rangarajan J.R., Ketkar-Atre A., Eriksson A.U., Ahlgreen U., Maes F., Himmelreich U., ''Co-registration and quantification of OPT and MR images of pancreatic islets'', Metabolic and functional research on diabetes, vol. 6, pp. 28, 2013 (4th international Brussels pancreatic islet symposium, May 30 - June 2, 2013, Brussels, Belgium).status: publishe

    Improved labeling of pancreatic islets using cationic magnetoliposomes

    No full text
    Pancreatic islets (PIs) transplantation is an alternative approach for the treatment of severe forms of type 1 diabetes (T1D). To monitor the success of transplantation, it is desirable to follow the location of engrafted PIs non-invasively. In vivo magnetic resonance imaging (MRI) of transplanted PIs is a feasible cell tracking method; however, this requires labeling with a suitable contrast agent prior to transplantation. We have tested the feasibility of cationic magnetoliposomes (MLs), compared to commercial contrast agents (Endorem and Resovist), by labeling insulinoma cells and freshly isolated rat PIs. It was possible to incorporate Magnetic Ressonance (MR)-detectable amounts of MLs in a shorter time (4 h) when compared to Endorem and Resovist. MLs did not show negative effects on the PIs’ viability and functional parameters in vitro. Labeled islets were transplanted in the renal sub-capsular region of healthy mice. Hypointense contrast in MR images due to the labeled PIs was detected in vivo upon transplantation, while MR detection of PIs labeled with Endorem and Resovist was only possible after the addition of transfection agents. These findings indicate that MLs are suitable to image PIs, without affecting their function, which is promising for future longitudinal pre-clinical and clinical studies involving the assessment of PI transplantation.SCOPUS: ar.jinfo:eu-repo/semantics/publishe

    Improved labeling of pancreatic islets using cationic magnetoliposomes

    No full text
    Pancreatic islets (PIs) transplantation is an alternative approach for the treatment of severe forms of type 1 diabetes (T1D). To monitor the success of transplantation, it is desirable to follow the location of engrafted PIs non-invasively. In vivo magnetic resonance imaging (MRI) of transplanted PIs is a feasible cell tracking method; however, this requires labeling with a suitable contrast agent prior to transplantation. We have tested the feasibility of cationic magnetoliposomes (MLs), compared to commercial contrast agents (Endorem and Resovist), by labeling insulinoma cells and freshly isolated rat PIs. It was possible to incorporate Magnetic Ressonance (MR)-detectable amounts of MLs in a shorter time (4 h) when compared to Endorem and Resovist. MLs did not show negative effects on the PIs' viability and functional parameters in vitro. Labeled islets were transplanted in the renal sub-capsular region of healthy mice. Hypointense contrast in MR images due to the labeled PIs was detected in vivo upon transplantation, while MR detection of PIs labeled with Endorem and Resovist was only possible after the addition of transfection agents. These findings indicate that MLs are suitable to image PIs, without affecting their function, which is promising for future longitudinal pre-clinical and clinical studies involving the assessment of PI transplantation.status: publishe

    Body distribution of SiO2-Fe3O4 core-shell nanoparticles after intravenous injection and intratracheal instillation

    No full text
    Nano-silicon dioxide (SiO2) is used nowadays in several biomedical applications such as drug delivery and cancer therapy, and is produced on an industrial scale as additive to paints and coatings, cosmetics and food. Data regarding the long-term biokinetics of SiO2 engineered nanoparticles (ENPs) is lacking. In this study, the whole-body biodistribution of SiO2 core-shell ENPs containing a paramagnetic core of Fe3O4 was investigated after a single exposure via intravenous injection or intratracheal instillation in mice. The distribution and accumulation in different organs was evaluated for a period of 84 days using several techniques, including magnetic resonance imaging, inductively coupled plasma mass spectrometry, X-ray fluorescence and X-ray absorption near edge structure spectroscopy. We demonstrated that intravenously administered SiO2 ENPs mainly accumulate in the liver, and are retained in this tissue for over 84 days. After intratracheal instillation, an almost complete particle clearance from the lung was seen after 84 days with distribution to spleen and kidney. Furthermore, we have strong evidence that the ENPs retain their original core-shell structure during the whole observation period. This work gives an insight into the whole-body biodistribution of SiO2 ENPs and will provide guidance for further toxicity studies.peerreview_statement: The publishing and review policy for this title is described in its Aims & Scope. aims_and_scope_url: http://www.tandfonline.com/action/journalInformation?show=aimsScope&journalCode=inan20status: publishe

    Body distribution of SiO<sub>2</sub>–Fe<sub>3</sub>O<sub>4</sub> core-shell nanoparticles after intravenous injection and intratracheal instillation

    No full text
    <p>Nano-silicon dioxide (SiO<sub>2</sub>) is used nowadays in several biomedical applications such as drug delivery and cancer therapy, and is produced on an industrial scale as additive to paints and coatings, cosmetics and food. Data regarding the long-term biokinetics of SiO<sub>2</sub> engineered nanoparticles (ENPs) is lacking. In this study, the whole-body biodistribution of SiO<sub>2</sub> core-shell ENPs containing a paramagnetic core of Fe<sub>3</sub>O<sub>4</sub> was investigated after a single exposure via intravenous injection or intratracheal instillation in mice. The distribution and accumulation in different organs was evaluated for a period of 84 days using several techniques, including magnetic resonance imaging, inductively coupled plasma mass spectrometry, X-ray fluorescence and X-ray absorption near edge structure spectroscopy. We demonstrated that intravenously administered SiO<sub>2</sub> ENPs mainly accumulate in the liver, and are retained in this tissue for over 84 days. After intratracheal instillation, an almost complete particle clearance from the lung was seen after 84 days with distribution to spleen and kidney. Furthermore, we have strong evidence that the ENPs retain their original core-shell structure during the whole observation period. This work gives an insight into the whole-body biodistribution of SiO<sub>2</sub> ENPs and will provide guidance for further toxicity studies.</p
    corecore