101 research outputs found

    Fluorophotometry as a diagnostic tool for the evaluation of dry eye disease

    Get PDF
    BACKGROUND: Dry eye disease is a common debilitating ocular disease. Current diagnostic tests used in dry eye disease are often neither sensitive nor reproducible, making it difficult to accurately diagnose and determine end points for clinical trials, or evaluate the usefulness of different medications in the treatment of dry eye disease. The recently developed fluorophotometer can objectively detect changes in the corneal epithelium by quantitatively measuring its barrier function or permeability. The purpose of the study is to investigate the use of corneal fluorescein penetration measured by the fluorophotometer as a diagnostic tool in the evaluation of dry eye patients. METHODS: Dry eye patients (16 eyes), who presented with a chief complaint of ocular irritation corresponding with dry eye, low Schirmer's one test (<10 mm after 5 minutes) and corneal fluorescein staining score of more than two, were included in the study. Normal subjects (16 eyes), who came for refraction error evaluation, served as controls. Institutional Review Board (IRB) approved consent was obtained before enrolling the subjects in the study and all questions were answered while explaining the risks, benefits and alternatives. All Fluorophotometry of the central corneal epithelium was done utilizing the Fluorotron Master (TradeMark). Each eye had a baseline fluorescein scan performed, after which 50 l of 1% sodium fluorescein dye was instilled. Three minutes later, the fluorescein was washed with 50 ml of normal saline. Fluorescein scans were then started immediately after washing and were recorded at 10, 20, 40, and 60 minutes thereafter. The corneal peak values of fluorescein concentration were recorded within the central cornea in both dry eyes and in controls. RESULTS: Ten minutes after fluorescein installition, patients with dry eye disease averaged a five-fold increase in corneal tissue fluorescein concentration (mean = 375.26 ± 202.67 ng/ml) compared with that of normal subjects (mean = 128.19 ± 85.84 ng/ml). Sixty minutes after dye installation, patients with dry eye disease still revealed higher corneal tissue fluorescein concentration (mean = 112.87 ± 52.83 ng/ml) compared with that of controls (mean = 40.64 ± 7.96 ng/ml), averaging a three-fold increase. CONCLUSION: Patients with dry eye disease demonstrated an increased corneal permeability and a slower rate of elimination to topically administered fluorescein when measured by the fluorophotometer. This suggests that fluorophotometry may serve as a valuable quantitative and objective tool for the diagnosis of dry eye disease, and in following patients' response to new treatment modalities. Fluorophotometry may serve as an objective non-invasive tool for end-point analysis in clinical trials of new treatments for dry eye disease

    Comparison of an immortalized human corneal epithelial cell line with Vero cells in the isolation of Herpes simplex virus-1 for the laboratory diagnosis of Herpes simplex keratitis

    Get PDF
    BACKGROUND: Herpes simplex keratitis (HSK) is a sight threatening ocular infection often requiring a specific and prompt laboratory diagnosis. Isolation of Herpes simplex virus (HSV-1) in culture provides the most reliable and specific method and is considered as the "Gold Standard" in the laboratory diagnosis of HSK in spite of its low sensitivity. Using "cell lines of corneal origin" for virus isolation may be beneficial under such circumstances, since these cells have been shown to be excellent substrates for the growth of HSV-1 isolated from the cornea. We report a comparative study of a novel human corneal epithelial cell line (HCE) and the Vero cell line in the isolation of HSV-1 from corneal scrapings employing a shell vial assay. METHODS: Corneal scrapings were obtained from 17 patients with a clinical diagnosis of HSK. All the cases were confirmed by virological investigations (PCR and viral antigen detection positive, n = 15, PCR positive, n = 1, Viral antigen positive, n = 1). Scrapings obtained from 10 patients with infectious keratitis of non-viral origin were included as controls. All the scrapings were simultaneously inoculated into shell vials of HCE and Vero cells. Cultures were terminated at 24 h post-infection. Isolation of HSV-1 was confirmed using an indirect immunofluorescence/ immunoperoxidase assay. RESULTS: Virus could be isolated using both or either of the cell lines in 10/17 (58.82%) patients with HSK. HSV-1 was isolated from 10/ 17 (58.82%) and 4/17(23.52%) specimens in HCE and Vero cells, respectively (P = 0.036). None of the controls yielded HSV-1. While all the 10 (100%) strains were isolated in HCE, Vero yielded only 4/10 (40%) strains in the shell vial culture (P = 0.014). CONCLUSIONS: HCE showed a statistically significant difference in the virus isolation rate with respect to Vero cells. HCE may be an excellent alternative cell line for the isolation of HSV-1, especially from corneal scrapings, for the laboratory diagnosis of HSK

    Time series analysis of age related cataract hospitalizations and phacoemulsification

    Get PDF
    BACKGROUND: Cataract surgery remains a commonly performed elective surgical procedure in the aging and the elderly. The purpose of this study was to utilize time series methodology to determine the temporal and seasonal variations and the strength of the seasonality in age-related (senile) cataract hospitalizations and phacoemulsification surgeries. METHODS: A retrospective, cross-sectional time series analysis was used to assess the presence and strength of seasonal and temporal patterns of age-related cataract hospitalizations and phacoemulsification surgeries from April 1, 1991 to March 31, 2002. Hospital admission rates for senile cataract (n = 70,281) and phacoemulsification (n = 556,431) were examined to determine monthly rates of hospitalization per 100,000 population. Time series methodology was then applied to the monthly aggregates. RESULTS: During the study period, age-related cataract hospitalizations in Ontario have declined from approximately 40 per 100,000 to only one per 100,000. Meanwhile, the use of phacoemulsification procedures has risen dramatically. The study found evidence of biannual peaks in both procedures during the spring and autumn months, and summer and winter troughs. Statistical analysis revealed significant overall seasonal patterns for both age-related cataract hospitalizations and phacoemulsifications (p < 0.01). CONCLUSION: This study illustrates the decline in age-related cataract hospitalizations in Ontario resulting from the shift to outpatient phacoemulsification surgery, and demonstrates the presence of biannual peaks (a characteristic indicative of seasonality), in hospitalization and phacoemulsification during the spring and autumn throughout the study period

    Psychological stress and other potential triggers for recurrences of herpes simplex virus eye infections

    Get PDF
    Objective To assess psychological stress and other factors as possible triggers of ocular herpes simplex virus (HSV) recurrences. Design A prospective cohort study nested in a randomized, placebo-controlled, clinical trial. Setting Fifty-eight community-based or university sites. Participants Immunocompetent adults (N = 308), aged 18 years or older, with a documented history of ocular HSV disease in the prior year and observed for up to 15 months. Exposure Variables Psychological stress, systemic infection, sunlight exposure, menstrual period, contact lens wear, and eye injury recorded on a weekly log. The exposure period was considered to be the week before symptomatic onset of a recurrence. Main Outcome Measure The first documented recurrence of ocular HSV disease, with exclusion of cases in which the exposure week log was completed late after the onset of symptoms. Results Thirty-three participants experienced a study outcome meeting these criteria. Higher levels of psychological stress were not associated with an increased risk of recurrence (rate ratio, 0.58; 95% confidence interval, 0.32-1.05; P = .07). No association was found between any of the other exposure variables and recurrence. When an analysis was performed including only the recurrences (n = 26) for which the exposure week log was completed late and after symptom onset, there was a clear indication of retrospective overreporting of high stress (P = .03) and systemic infection (P = .01). Not excluding these cases could have produced incorrect conclusions due to recall bias. Conclusions Psychological stress does not appear to be a trigger of recurrences of ocular HSV disease. If not accounted for, recall bias can substantially overestimate the importance of factors that do not have a causal association with HSV infection

    Intensity modulated radiotherapy for high risk prostate cancer based on sentinel node SPECT imaging for target volume definition

    Get PDF
    BACKGROUND: The RTOG 94-13 trial has provided evidence that patients with high risk prostate cancer benefit from an additional radiotherapy to the pelvic nodes combined with concomitant hormonal ablation. Since lymphatic drainage of the prostate is highly variable, the optimal target volume definition for the pelvic lymph nodes is problematic. To overcome this limitation, we tested the feasibility of an intensity modulated radiation therapy (IMRT) protocol, taking under consideration the individual pelvic sentinel node drainage pattern by SPECT functional imaging. METHODS: Patients with high risk prostate cancer were included. Sentinel nodes (SN) were localised 1.5–3 hours after injection of 250 MBq (99m)Tc-Nanocoll using a double-headed gamma camera with an integrated X-Ray device. All sentinel node localisations were included into the pelvic clinical target volume (CTV). Dose prescriptions were 50.4 Gy (5 × 1.8 Gy / week) to the pelvis and 70.0 Gy (5 × 2.0 Gy / week) to the prostate including the base of seminal vesicles or whole seminal vesicles. Patients were treated with IMRT. Furthermore a theoretical comparison between IMRT and a three-dimensional conformal technique was performed. RESULTS: Since 08/2003 6 patients were treated with this protocol. All patients had detectable sentinel lymph nodes (total 29). 4 of 6 patients showed sentinel node localisations (total 10), that would not have been treated adequately with CT-based planning ('geographical miss') only. The most common localisation for a probable geographical miss was the perirectal area. The comparison between dose-volume-histograms of IMRT- and conventional CT-planning demonstrated clear superiority of IMRT when all sentinel lymph nodes were included. IMRT allowed a significantly better sparing of normal tissue and reduced volumes of small bowel, large bowel and rectum irradiated with critical doses. No gastrointestinal or genitourinary acute toxicity Grade 3 or 4 (RTOG) occurred. CONCLUSION: IMRT based on sentinel lymph node identification is feasible and reduces the probability of a geographical miss. Furthermore, IMRT allows a pronounced sparing of normal tissue irradiation. Thus, the chosen approach will help to increase the curative potential of radiotherapy in high risk prostate cancer patients

    Ring electrode for radio-frequency heating of the cornea: modelling and in vitro experiments

    Full text link
    [EN] Radio-frequency thermokeratoplasty (RF-TKP) is a technique used to reshape the cornea curvature by means of thermal lesions using radio-frequency currents. This curvature change allows refractive disorders such as hyperopia to be corrected. A new electrode with ring geometry is proposed for RF-TKP. It was designed to create a single thermal lesion with a full-circle shape. Finite element models were developed, and the temperature distributions in the cornea were analysed for different ring electrode characteristics. The computer results indicated that the maximum temperature in the cornea was located in the vicinity of the ring electrode outer perimeter, and that the lesions had a semi-torus shape. The results also indicated that the electrode thickness, electrode radius and electrode thermal conductivity had a significant influence on the temperature distributions. In addition, in vitro experiments were performed on rabbit eyes. At 5 IN power the lesions were fully circular. Some lesions showed non-uniform characteristics along their circular path. Lesion depth depended on heating duration (60% of corneal thickness for 20s, and 30% for 10s). The results suggest that the critical shrinkage temperature (55-63degreesC) was reached at the central stroma and along the entire circular path in all the cases.Berjano, E.; Saiz Rodríguez, FJ.; Alió, J.; Ferrero, JM. (2003). Ring electrode for radio-frequency heating of the cornea: modelling and in vitro experiments. Medical & Biological Engineering & Computing. 41(6):630-639. https://doi.org/10.1007/BF02349970S630639416Alió, J. L., Ismail, M. M., Artola, A., andPérez-Santonja, J. J. (1997a): ‘Correction of hyperopia induced by photorefractive keratectomy using non-contact Ho: YAG laser thermal keratoplasty’,J. Refract. Surg.,13, pp. 13–16Alió, J. L., Ismail, M. M., andSanchez, J. L. (1997b): ‘Correction of hyperopia with non-contact Ho: YAG laser thermal keratoplasty’,J. Refract. Surg.,13, pp. 17–22Alió, J. L., andPérez-Santonja, J. J. (1999): ‘Correction of hyperopia by laser thermokeratoplasty (LTK)’ inPallikaris, I., andAgarwal, S. (Eds): ‘Refractive Surgery’ (Jaypee Brothers Medical Publishers Ltd, New Delhi, 1999), pp. 583–591Alió, J. L., andPérez-Santonja, J. J. (2002): ‘Correction of hyperopia by laser thermokeratoplasty (LTK)’ inAgarwal, S., Agarwal, A., Apple, D. J., Buratto, L., Alió, J. L., Pandey, S. K., andAgarwal, A. (Eds): ‘Textbook of ophthalmology’ (Lippincott Williams & Wilkins, Philadelphia, 2002), pp. 1331–1337Ayala, M. J., Alió, J. L., Ismail, M. M., andSánchez-Castro, J. M. (2000): ‘Experimental corneal histological study after thermokeratoplasty with holmium laser’,Arch. Soc. Esp. Oftalmol.,75, pp. 619–626Asbell, P. A., Maloney, R. K., Davidorf, J., Hersh, P., McDonald, M., Manche, E., andConductive Keratoplasty Study Group (2001): ‘Conductive keratoplasty for the correction of hyperopia’,Tr. Am. Ophtalmol. Soc.,99, pp. 79–87Avitall, B., Mughal, K., Hare, J., Helms, R., andKrum, D. (1997): ‘The effects of electrode-tissue contact on radiofrequency lesion generation’PACE,20, pp. 2899–2910Avitall, B., Helms, R. W., Koblish, J. B., Sieben, W., Kotov, A. V., andGupta, G. N. (1999): ‘The creation of linear contiguous lesions in the atria with an expandable loop catheter’,J. Am. Coll. Cardiol.,33, pp. 972–984Berjano, E. J., Saiz, J., andFerrero, J. M. (2002): ‘Radio-frequency heating of the cornea: Theoretical model andin vitro experiments’,IEEE Trans. Biomed. Eng.,49, pp. 196–205Brickmann, R., Kampmeier, J., Grotehusmann, U., Vogel, A., Koop, N., Asiyo-Vogel, M., Kamm, K., andBirngruber, R. (1996): ‘Corneal collagen denaturation in laserthermokeratoplasty’,SPIE Proc.,2681, pp. 56–63Choi, B., Kim, J., Welch, A. J., andPearce, J. A. (2002): ‘Dynamic impedance measurements during radio-frequency heating of cornea’,IEEE Trans. Biomed. Eng.,49, pp. 1610–1616Curley, M. G., andHamilton, P. S. (1997): ‘Creation of large thermal lesions in liver using saline-enhanced RF ablation’. Proc. 19th Ann. Int. Conf. IEEE Eng. Med. Biol. Soc., Chicago, pp. 2516–2519Doss, J. D., andAlbillar, J. I. (1980): ‘A technique for the selective heating of corneal stroma’,Contact Intraocular Lens Med.,6, pp. 13–17Doss, J. D. (1982): ‘Calculation of electric fields in conductive media’,Med. Phys.,9(4), pp. 566–573Gruenberg, P., Manning, W., Miller, D. andOlson, W. (1981): ‘Increase in rabbit corneal curvature by heated ring application’,Ann. Ophthalmol.,13, pp. 67–70Hata, C., andRaymond Chia, W.-K. (2001): ‘Catheter for circular tissue ablation and methods thereof’. US Patent 2001/0044625 A1Jain, M. K., andWolf, P. D. (1998): ‘Effect of electrode contact on lesion growth during temperature controlled radiofrequency ablation’, Proc. 20th Ann. Int. Conf. IEEE Eng. Med. Biol. Soc. Hong Kong (IEEE, Piscataway NJ) pp. 245–247Jain, M. K., andWolf, P. D. (1999): ‘Temperature controlled and constant power radiofrequency ablation: what affects lesion growth?’,IEEE Trans. Biomed. Eng.,46, pp. 1405–1412Krasteva, V. Tz., andPapazov, S. P. (2002): ‘Estimation of current density distribution under electrodes for external defibrillation’,Biomed. Eng. OnLine,1, 7Labonté, S. (1992): ‘A theoretical study of radio-frequency ablation of the myocardium’,PhD dissertation, Department of Electrical Engineering, University of Ottawa, CanadaLabonté, S. (1994): ‘Numerical model for radio-frequency ablation of the endocardium and its experimental validation’,IEEE Trans. Biomed. Eng.,41, pp. 108–115Mannis, M. J., Segal, W. A., andDarlington, J. K. (2001): ‘Making sense of refractive surgery in 2001: Why, when, for whom, and by whom?’,Mayo Clin. Proc.,76, pp. 823–829McCally, R. L., Bargeron, R. A., andGreen, W. R. (1983): ‘Stromal damage in rabbit corneas exposed to CO2 laser radiation’,Exp. Eye Res.,37, pp. 543–550McDonald, M. B., Hersh, P. S., Manche, E. E., Maloney, R. K., Davidorf, J., andSabry, M. (2002): ‘Conductive keratoplasty for the correction of low to moderate hyperopia: U.S. clinical trial 1-year results on 355 eyes’,Ophthalmol.,109, pp. 1978–1989McRury, I. D., Mitchell, M. A., Panescu, D. andHaines, D. E. (1997): ‘Non-uniform heating during radiofrequency ablation with long electrodes: monitoring the edge effect’,Circ.,96, pp. 4057–4064Méndez-g, A., andMéndez-Noble, A. (1997): ‘Conductive keratoplasty of the correction of hyperopia’ inSher, N. A. (Ed.) ‘Surgery for hyperopia and presbyopia’ (Williams & Wilkins, Baltimore, 1997), pp. 163–171Miller, D., andManning, W.J. (1978): ‘Alterations in curvature of bovine cornea using heated rings’,Invest. Ophthalmol., p. 297Mirotznik, M. S., andSchwartzman, D. (1996): ‘Nonuniform heating patterns of commercial electrodes for radiofrequency catheter ablation’,J. Cardiovasc. Electrophysiol.,7, pp. 1058–1062Nakagawa, H., Yamanashi, W. S., Pitha, J. V., Arruda, M., Wang, X., Ohtomo, K., Beckman, K. J., McClelland, J. H., Lazzara, R., andJackman, W. M. (1995): ‘Comparison ofin vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation’,Circ.,91, pp. 2264–2273Panescu, D., Whayne, J. G., Fleischman, S. D., Mirotznik, M. S., Swanson, D. K., andWebster, J. G. (1995): ‘Three-dimensional finite element analysis of current density and temperature distributions during radio-frequency ablation’,IEEE Trans. Biomed. Eng.,42, pp. 879–890Plonsey, R., andHeppner, D. B. (1967): ‘Considerations of quasistationarity in electrophysiological systems’,Bull. Math. Biophys.,29, pp. 657–664Rowsey, J. J. (1987): ‘Electrosurgical keratoplasty: Update and retraction’,Invest. Ophthalmol. Vis. Sci.,28, p. 224Rutzen, A. R., Roberts, C. W., Driller, J., Gomez, D., Lucas, B. C., Lizzi, F. L., andColeman, D. J. (1990): ‘Production of corneal lesions using high-intensity focused ultrasound’,Cornea,9, pp. 324–330Schwan, H. P., andFoster, K. R. (1980): ‘RF-fields interactions with biological systems: electrical properties and biophysical mechanism’,Proc. IEEE,68, pp. 104–113Seiler, T., Matallana, M., andBende, T. (1990): ‘Laser thermokeratoplasty by means of a pulsed Holmium:YAG Laser for the hyperopic correction’,Refrac. Corneal Surg.,6, pp. 335–339Silvestrini, T. A. (1998): ‘Electrosurgical procedure for the treatment of the cornea’. US Patent 5,766,171Simmons, W. N., Mackey, S., He, D. S. andMarcus, F. L. (1996): ‘Comparison of gold versus platinum electrodes on myocardial lesion size using radiofrequency energy’,PACE,19, pp. 398–402Stringer, H., andParr, J. (1964): ‘Shrinkage temperature of eye collagen’,Nature,204, p. 1307Trembly, B. S., andKeates, R. H. (1991): ‘Combined microwave heating and surface cooling of the cornea’,IEEE Trans. Biomed. Eng.,38, pp. 85–91Trembly, B. S., Hashizume, N., Moodie, K. L., Cohen, K. L., Tripoli, N. K., andHoopes, P. J. (2001): ‘Microwave thermal keratoplasty for myopia: keratoscopic evaluation in porcine eyes’,J. Refract. Surg.,17, pp. 682–688Tungjitkusolmun, S., Woo, E. J., Cao, H., Tsai, J. Z., Vorperian, V. R., andWebster, J. G. (2000): ‘Thermal-electrical finite element modelling for radio frequency cardiac ablation: effects of changes in myocardial properties’,Med. Biol. Eng. Comput.,38, pp. 562–568Wiley, J. D., andWebster, J. G. (1982): ‘Analysis and control of the current distribution under circular dispersive electrodes’,IEEE Trans. Biomed. Eng,29, pp. 381–38

    Treatment of ocular allergies:nonpharmacologic, pharmacologic and immunotherapy

    Get PDF
    Ocular allergy is a significant and growing issue worldwide but for many patients, it is often not differentiated from systemic conditions, such as hay fever. Management of seasonal and perennial allergic conjunctivitis is often poor. Management is principally through avoidance measures (blocking or hygiene), nonpharmaceutical (such as artificial tears and cold compresses) and pharmaceutical (such as topical antihistamines and prophylactic mast cell stabilizers). Vernal and atopic keratoconjunctivitis are more severe and generally need treatment with NSAIDs, steroids and immunomodulators. Giant papillary conjunctivitis can be related to allergy but also is often contact lens related and in such cases can be managed by a period of abstinence and replacement of the lens or a change in lens material and/or design. Immunotherapy can be efficacious in severe, persistent cases of contact lens or allergic conjunctivitis
    • …
    corecore