15 research outputs found

    Spondylarthropathies (including psoriatic arthritis): 244. Validity of Colour Doppler and Spectral Doppler Ultrasound of Sacroilicac Joints Againts Physical Examination as Gold Standard

    Get PDF
    Background: Sacroiliac joints (SJ) involvement is a distinctive and charasteristic feature of Spondyloarthritis (SpA) and x-ray is the test routinely used to make a diagnosis. However, x-ray reveals late structural damage but cannot detect active inflammation. The objective of this study was to assess the validity of Doppler ultrasound in SJ. Methods: Prospective blinded and controlled study of SJ, in which three populations were compared. We studied 106 consecutive cases, who were divided into three groups: a) 53 patients diagnosed with SpA who had inflammatory lumbar and gluteal pain assessed by a rheumatologist; b) 26 patients diagnosed with SpA who didn't have SJ tenderness and had normal physical examination; c) control group of 27 subjects (healthy subjetcs or with mechanical lumbar pain). All patients included that were diagnosed with SpA met almost the European Spondyloarthropathy Study Group (ESSG) classification criteria. Physical examination of the SJ included: sacral sulcus tenderness, iliac gapping, iliac compression, midline sacral thrust test, Gaenslen's test, and Patrick s test were used as gold standard. Both SJ were examined with Doppler ultrasound (General Electric Logiq 9, Wauwatosa WI, USA) fitted with a 9-14 Mhz lineal probe. The ultrasonographer was blinded to clinical data. Doppler in SJ was assessed as positive when both Doppler colour and resistance index (RI) < 0.75 within the SJ area were present. Statistical analysis was performed estimating sensitivity and specificity against gold standard. The Kappa correlation coefficient was used for reliability study. Results: 106 cases (53 female, 55 male; mean age 36 10 years) were studied. There were no statistical differences between groups related to age or sex. Physical examination of SJ was positive in 38 patients (59 sacroiliac joints). US detected Doppler signal within SJ in 37 patients (58 SJ): 33 of them were symptomatic SpA (52 SJ), one of them were asymptomatic SpA (1 SJ) and one was a healthy control (1 SJ). The accuracy of US when compared to clinical data as gold standard at subject level in the overall group was: sensitivity of 68.6% and specificity of 85.7%, positive predictive value of 70.5% and negative predictive value of 84.5%. A positive likelihood ratio of 4.8, a negative likelihood ratio of 0.36 and a kappa coefficient of 0.55 were achieved. Conclusions: Doppler US of SJ seems to be a valid method to detect active SJ inflammation. Disclosure statement: The authors have declared no conflicts of interes

    Monitoring of radiation levels in medical cyclotron facility measured by a comprehensive computerized monitoring system

    No full text
    790-793The medical cyclotron facility at Institute of Nuclear Medicine and Allied Sciences, Delhi, has an unshielded bunker type medical cyclotron (16.5 MeV) for the production of positron emitting radionuclides namely 18F, 15O, 13N and 11C. The pharmaceuticals labeled with these radioisotopes are used for positron emission tomography (PET) imaging. The medical cyclotron facility has an associated radiochemistry facility that contains chemistry modules housed in adequately shielded hot cells meant for the synthesis of the pharmaceuticals labeled with these positron emitters. The facility also has a beam extension room. The radiation levels were measured in the facility at different locations namely cyclotron vault, control console, radiochemistry laboratory, beam extension room and the stack using a comprehensive computerized monitoring system. The radiation levels were observed to be well within the prescribed limits

    Estimation of patient dose in 18

    No full text
    Purpose: To estimate specific organ and effective doses to patients resulting from the 18 F-FDG ( 18 F-2-deoxy-D-glucose) and 18 F-FDOPA (6-fluoro-( 18 F)-L-3, 4-dihydroxyphenylalanine) PET/CT examinations for whole body and brain. Materials and Methods: Three protocols for whole body and three for brain PET/CT were used. The CTDI values were measured using standard head and body CT phantoms and also computed using a software CT-Expo for dose evaluation from the CT component. OLINDA software based on MIRD method was used for estimating doses from the PET component of the PET/CT examination. Results: The organ doses from 18 F-FDG and 18 F-FDOPA whole body and brain PET/CT studies were estimated. The total effective dose from a typical protocol of whole body PET/CT examination was 14.4 mSv for females and 11.8 mSv for male patients from 18 F-FDG, whereas it was 11 mSv for female and 9.1 mSv for male patients from 18 F-FDOPA. The total effective doses from a typical protocol for PET/CT studies of brain was 6.5 mSv for females and 5.1 mSv for males from 18 F-FDG whereas it was 3.7 mSv for females and 2.8 mSv for males from 18 F-FDOPA. Conclusions: The effective radiation doses from whole body PET/CT examination was approximately 4-8 times higher than the background radiation dose from both 18 F-FDG and 18 F-FDOPA scans, while it was 1-3 times the background radiation dose from PET/CT scans of brain

    Scholars Journal of Medical Case Reports ISSN 2347-9507 (Print) Fracture in Pregnancy: A Case Report

    No full text
    Abstract: 36 year old multigravida, at 16 weeks of pregnancy presented with history of road traffic accident and was diagnosed to have fracture shaft of radius (lower 3 rd ). As closed reduction was unsuccessful, open reduction and internal fixation with low contact dynamic compression plate was done.

    Estimation of radiation dose to patients from 18 FDG whole body PET/CT investigations using dynamic PET scan protocol

    No full text
    Background & objectives: There is a growing concern over the radiation exposure of patients from undergoing 18FDG PET/CT (18F-fluorodeoxyglucose positron emission tomography/computed tomography) whole body investigations. The aim of the present study was to study the kinetics of 18FDG distributions and estimate the radiation dose received by patients undergoing 18FDG whole body PET/CT investigations. Methods: Dynamic PET scans in different regions of the body were performed in 49 patients so as to measure percentage uptake of 18FDG in brain, liver, spleen, adrenals, kidneys and stomach. The residence time in these organs was calculated and radiation dose was estimated using OLINDA software. The radiation dose from the CT component was computed using the software CT-Expo and measured using computed tomography dose index (CTDI) phantom and ionization chamber. As per the clinical protocol, the patients were refrained from eating and drinking for a minimum period of 4 h prior to the study. Results: The estimated residence time in males was 0.196 h (brain), 0.09 h (liver), 0.007 h (spleen), 0.0006 h (adrenals), 0.013 h (kidneys) and 0.005 h (stomach) whereas it was 0.189 h (brain), 0.11 h (liver), 0.01 h (spleen), 0.0007 h (adrenals), 0.02 h (kidneys) and 0.004 h (stomach) in females. The effective dose was found to be 0.020 mSv/MBq in males and 0.025 mSv/MBq in females from internally administered 18FDG and 6.8 mSv in males and 7.9 mSv in females from the CT component. For an administered activity of 370 MBq of 18FDG, the effective dose from PET/CT investigations was estimated to be 14.2 mSv in males and 17.2 mSv in females. Interpretation & conclusions: The present results did not demonstrate significant difference in the kinetics of 18FDG distribution in male and female patients. The estimated PET/CT doses were found to be higher than many other conventional diagnostic radiology examinations suggesting that all efforts should be made to clinically justify and carefully weigh the risk-benefit ratios prior to every 18FDG whole body PET/CT scan

    Control of Aedes aegypti and Ae. albopictus, the vectors of dengue and chikungunya, by using pheromone C21 with an insect growth regulator: Results of multicentric trials from 2007-12 in India

    No full text
    Background & objectives: Aedes mosquito control has gained much importance nowadays in view of rise in number of reported cases of dengue and chikungunya in India and other countries. In the present study, C21 attracticide (containing a pheromone and an insect growth regulator-IGR, developed by Defence Research and Development Establishment (DRDE), Gwalior, India was tested for its feasibility for surveillance and control of Aedes mosquito in a multicentric mode from October 2007 to June 2012 in urban (Delhi, and Bengaluru district, Karnataka) and suburban (Alappuzha district, Kerala) settings of the country in three phases. Methods: Across the randomly selected households in each study area, two to four containers treated with attracticide (experimental) and untreated (control) were placed and monitored by trained surveillance workers on weekly/ fortnightly basis for determining the presence of eggs, larvae and pupae. Container positivity, percent larvae, egg and pupae collected were determined during different phases and analyzed statistically using SPSS 18.0. Results: Container positivity was found statistically significant at Bengaluru and Alappuzha, Kerala while in Delhi, it was found non-significant. Eggs collected from experimental containers were significantly higher in comparison to control at all the locations except Delhi. Also larvae collected from control containers were significantly higher at all the locations except Bengaluru. Pupae collected from control containers remained significantly higher at all the locations as no pupal formation was recorded from experimental containers. Interpretation & conclusion: The use of C21 attracticide hampered pupal formation, thus inhibiting adult population in the study areas. The study established that C21 attracticide was efficacious in the field conditions and has potential for use in surveillance and management of dengue and chikungunya mosquitoes
    corecore