23 research outputs found

    Forearm-attachable EMG-based wireless controller

    Get PDF
    This paper presents the development process starting from a simple electronic module for amplification of EMG signals. During development the tasks to be solved were extended towards the creation of an EMG-base controller that eventually can be connected to a PC. Among the main goals were the simplicity and low cost of production. There are similar devices commercially available, but the main focus was on the whole process of design, testing, fabrication and the exploration of application areas. It was important to use medical recommendations. The device matches the suggestion of SENIAM, except for the resolution of A/D conversion, which is permissible due to the fact that it was not designed for medical purposes. The final version is capable of detecting and amplifying EMG signals, with the appropriate filtering and digitizing procedures for further processing. With the development of wireless communication capabilities, the device which can be attached to the forearm can be used as a USB HID device with a PC. A number of additional applications are also discussed, pointing out the fact that this piece of technology offers a wide range of possibilities

    Evaluation of Three Different Phalangeal Motion Measurement Systems and Determination of the Functional Range of Motion

    Get PDF
    The main contribution of this paper is the introduction of three different devices for measuring the flexion of phalangeal articulations. The devices described in the study are suitable for the determination of the active and the functional range of motion (ROM) of finger joints. In the paper, multiple measurements are reported in order to determine the maximum and minimum values of the active and the functional range of motion of phalangeal articulations and to validate the proper operation of the measurement devices. The first measurement method was based on the post factum image processing of video recordings, while the second and the third method used devices that were attached to the finger and equipped with analogue and digital sensors, which is similar to a miniature goniometer with a computer interface. The results showed that people only use 79-82% of the active range of motion of phalangeal articulations. Additionally, there was a 6% difference between the current measurement results and the data available from previously reported measurements. The current study also aims at finding the cause of this anomaly. Comparative analysis of the measurement results provides a basis for the future development of an actuator that would be used in a multiple finger gripper mechanism suitable for rehabilitation purposes

    New aspects in grouping typical injuries from road traffic accidents

    Get PDF
    Typical mechanisms and specifi c injuries of people involved in road traffi c accidents are presented.Injury patterns specifi c to occupants of vehicles with enclosed passenger compartment, as well as unprotected participants of traffi c (pedestrians, bicyclists, motorcyclists, etc.) are grouped.Injury severity classifi cation, treatment planning and outcome prediction is usually done based on various scoring systems, both internationally and in Hungary. The enormous number of such scoring systems make a thorough survey diffi cult and conversion among these scores has limitations. However prehospital care providers and hospital emergency staff need a “common language”, preferably a system that utilizes the advantages of scoring systems. There is no uniform practice of this communication and data transfer in Hungary now, that is why part of the important data from the incident scene might not get to the hospital together with the patient.The documentation of prehospital care providers both in Hungary and abroad are discussed and analyzed. Score systems in prehospital and emergency medicine, as well as outcome prediction measures are covered. Data collection schemes especially the Utstein-Style for documenting major trauma and the German MIND2 (Minimale Notarztdatensatz, minimal prehospital care data set) are also presented.A suggestion is introduced for the data content of prehospital documentation, so that it could further help hospital admission and care. The main aspects of the suggestion are road traffi c accidents, because the creation of such a widely accepted and used document (a prehospital patient report form) requires a team of experts from various – mainly medical – specialties. Technical aspects, such as digital data collection are also covered. Future directions of development are named, too. DOI: 10.17489/biohun/2010/1/0

    Retaining hand biomechanics in case of a hand tumor

    Get PDF
    The case of a patient with lung cancer is presented whose fi rst metastasis was detected in the 5th metacarpal head. Hand metastasis in lung cancer is a rarity in literature. After the detection of the hand tumor treatment was sidetracked by representatives of other medical specialities. The growing tumor destroyed the 3rd, 4th and 5th metacarpals, thus based on DSA, MRI, CT, PET-CT and X-ray results and thorough planning of the surgical procedures only opposition and grip of thumb and index fi nger was possible to form. During surgery unexpected diffi culties occured partly because of the condtion of tissues, partly because the tumor was infected. It was not possible to plan exactly before the procedure due to the nature of the tumor, and according to the hystological results, the metastasis was cleared only by 6 mm. It was possible to rescue the 2nd metacarpal with the atypical insertion of an AO-plate, so that the fi nal statics of the hand was secured. The postoperative period proved to be reassuring, however due to the quick progression of the underlying disease the patient was lost. DOI: 10.17489/biohun/2010/1/2

    Biokompatibilis nyúlásmérő bélyeg szerkezeti és mechanikai vizsgálata

    Get PDF
    A következĹ‘tanulmány egy biokompatibilis bevonattal ellátott, villamosan vezetĹ‘, szilikon alap-anyagú nyúlásmérĹ‘bélyeg tervezését, a próbadarabok elkészítését, az elvégzett vizsgálatokat, valamint azok eredményeit foglalja össze. A tervezési feladat a meglévĹ‘villamosan vezetĹ‘szilikon nyúlásmérĹ‘bélyeg biokompatibilissé tétele volt, tehát a bevonat lehetséges alapanyagainak meg-határozása, létrehozásának lehetĹ‘ségei és a megvalósítható módszer kiválasztása után a próba-testek gyártásához szükséges szerszámok létrehozása is idetartozik. Az elkészített próbadarabok esetén vizsgáltuk, hogy a még teljesen használatlan nyúlásmérĹ‘ bélyeg konstans és ciklikus mechanikai terhelés hatására produkál-e bármilyen tranziens jelenséget, amennyiben igen, milyen annak jellege és mértéke. Pásztázó elektronmikroszkóp segítségével elemeztük a nyúlásmérĹ‘bélyeg felépítését, meghatároztuk a villamosan vezetĹ‘szilikon és a biokompatibilis réteg közötti átmenet jellegét. Az eredmények azt mutatják, hogy a nyú-lásmérĹ‘k alapanyagtól függĹ‘en különbözĹ‘mértékben, de mindenképpen átesnek egy tranziens beálláson. Megállapítható, hogy a szilikonok polimerizációját elĹ‘segítĹ‘katalizátoroktól függĹ‘en a biokompatibilis bevonat és a villamosan vezetĹ‘alap nem minden alapanyag esetén képes megfelelĹ‘térhálósodásra. DOI: 10.17489/biohun/2014/1/01&nbsp
    corecore