71 research outputs found

    EmboASSIST a new software to help endovascular treatment of brain AVMs

    Get PDF
    International audienceEmboASSIST (GE Healthcare) is a new 3D visualization software dedicated to assist AVM embolization. It provides a one-click 3D segmentation of vascular anatomy from CBCT acquisition then dynamically track feeders and simulate virtual injections. These segmented feeders can be displayed on live fluoroscopy facilitating micro catheter navigation. Moreover, 3D MR acquisition may be automatically registered with CBCT acquisition and also displayed on live fluoroscopy

    The Latest Technologies and Information on GE InnovaIQ in 2009

    No full text

    An automatic MRI quality control procedure: Multisite reports for slice thickness and geometric accuracy

    No full text
    International audienceIn this work, we report multi-scanner quality control monitoring using a standard and automated protocol. This magnetic resonance imaging quality control protocol, based on the American College of Radiology procedures, includes weekly scans of a dedicated phantom followed by specific measurements. The processing step commonly involves manually-performed operations which can be tedious and time-consuming hence motivating their automation. QC data were collected in four sites; data from one of them served for the validation of the automatic analysis tool. Designed as a package of MATLAB® functions, this tool was successfully validated using Student's t-test and the correlation between automatic measurements and the manual ones. Besides, the multisite QC study enabled to compare the performances of these four MR facilities. In order to avoid misinterpretation or errors in multicenter clinical studies, such approach can be recommended as a preliminary step for including a site in the studies

    Nontraumatic subarachnoid hemorrhage management: evaluation with reduced iodine volume at CT angiography.

    No full text
    PURPOSE: To evaluate the technical quality and the diagnostic performance of a protocol with use of low volumes of contrast medium (25 mL) at 64-detector spiral computed tomography (CT) in the diagnosis and management of adult, nontraumatic subarachnoid hemorrhage (SAH). MATERIALS AND METHODS: This study was performed outside the United States and was approved by the institutional review board. Intracranial CT angiography was performed in 73 consecutive patients with nontraumatic SAH diagnosed at nonenhanced CT. Image quality was evaluated by two observers using two criteria: degree of arterial enhancement and venous contamination. The two independent readers evaluated diagnostic performance (lesion detection and correct therapeutic decision-making process) by using rotational angiographic findings as the standard of reference. Sensitivity, specificity, and positive and negative predictive values were calculated for patients who underwent CT angiography and three-dimensional rotational angiography. The intraclass correlation coefficient was calculated to assess interobserver concordance concerning aneurysm measurements and therapeutic management. RESULTS: All aneurysms were detected, either ruptured or unruptured. Arterial opacification was excellent in 62 cases (85%), and venous contamination was absent or minor in 61 cases (84%). In 95% of cases, CT angiographic findings allowed optimal therapeutic management. The intraclass correlation coefficient ranged between 0.93 and 0.95, indicating excellent interobserver agreement. CONCLUSION: With only 25 mL of iodinated contrast medium focused on the arterial phase, 64-detector CT angiography allowed satisfactory diagnostic and therapeutic management of nontraumatic SAH
    corecore