163 research outputs found

    Effect of tomato by-products in the diet of Comisana sheep on composition and conjugated linoleic acid (CLA) content of milk fat

    Get PDF
    To evaluate the effect of supplementing the diet of Comisana sheep with by-products from industrial tomato manifacture on the composition and conjugated linoleic acid (CLA) content of milk fat, two groups of 50 ewes each were fed either total mixed ration standard (TMRS) or total mixed ration with added tomato by-products (TMRA). Milk fat composition was determinated by HRGC. The milk fat content for animals fed the TMRA diet increased by 6,41% aafter six weeks, compared with the animals fed the TMRS diet. The CLA content in the milk fat for the group of animal fed the TMRA diet was 19,8% higher than for those fed the TMRS diet. The fatty acid composition showed an increase in the amount of PUFA; the n-3:n-6 ratio increased by 13% in the milk from sheep fed with the TMRA diet

    Near field behavior of SnO 2 particle-layer deposited on standard optical fiber by electrostatic spray pyrolysis method

    Get PDF
    We report the emergent optical near field profiles from standard single mode optical fibers on the cleaved end of which were deposited particle layers of SnO(2). The layers, composed of micron and sub-micron sized particles, were deposited by means of Electrostatic Spray Pyrolysis (ESP) technique. Powerful analytical tools such as Atomic Force Microscopy (AFM) and Scanning Near-field Optical Microscopy (SNOM) were used to obtain simultaneously the SnO(2) layers topography and the related optical near field intensity distribution, when the fiber-substrate is illuminated by a light radiation in NIR range. We show that isolated microstructures, positioned in correspondence of the fiber core, reveal highly unusual capability of locally enhancing the collected optical near field. The observed phenomenon leads to new concepts of fiber optic chemical sensors and in fiber microsystems as well

    Simultaneous Measurement of Cortisol, Cortisone, Dexamethasone and Additional Exogenous Corticosteroids by Rapid and Sensitive LC–MS/MS Analysis

    Get PDF
    The simultaneous measurement of dexamethasone and cortisol has proven the ability to increase the diagnostic performance of the overnight dexamethasone-suppression test. Furthermore, the therapeutic drug monitoring of administered corticosteroid drugs could represent a crucial tool for investigating unexpected variations of steroid hormones’ circulating levels. In this work, an LC–MS/MS method for the quantification of cortisol, cortisone, dexamethasone and six additional exogenous corticosteroids in the serum/plasma matrix was developed and validated in compliance with the ISO/IEC requirements. To assess the efficiency of the validated method, serum samples of 75 patients undergoing the dexamethasone-suppression test and 21 plasma samples of patients under immunosuppressive treatment after kidney transplant were analyzed. In all dexamethasone-suppression test samples, it was possible to measure the circulating levels of cortisol, cortisone and dexamethasone. Concentrations of the latter were for all tested patients above the proposed cutoff for the dexamethasone-suppression test’s results, and the cortisol concentrations showed good correlation with the ones measured by routine immunometric analysis, therefore confirming the screening outcome for all enrolled patients. Prednisone was detected and quantified in all enrolled patients, confirming the use of such a corticosteroid for immunosuppressive therapy. Thanks to these two applications, we proved the overall performance of the developed LC–MS/MS method for four target analytes. The future implementation of such an analytical tool in the clinical biochemistry laboratory’s routine will guarantee a single and versatile tool for simultaneously monitoring dexamethasone-suppression-test results and corticosteroid drugs’ administration

    Transition mode long period grating biosensor with functional multilayer coatings

    Get PDF
    We report our latest research results concerning the development of a platform for label-free biosensing based on overlayered Long Period Gratings (LPGs) working in transition mode. The main novelty of this work lies in a multilayer design that allows to decouple the problem of an efficient surface functionalization from that of the tuning in transition region of the cladding modes. An innovative solvent/nonsolvent strategy for the dip-coating technique was developed in order to deposit on the LPG multiple layers of transparent polymers. In particular, a primary coating of atactic polystyrene was used as high refractive index layer to tune the working point of the device in the so-called transition region. In this way, state-of-the-art-competitive sensitivity to surrounding medium refractive index changes was achieved. An extremely thin secondary functional layer of poly(methyl methacrylate-co-methacrylic acid) was deposited onto the primary coating by means of an original identification of selective solvents. This approach allowed to obtain desired functional groups (carboxyls) on the surface of the device for a stable covalent attachment of bioreceptors and minimal perturbation of the optical design. Standard 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide / N-hydrosuccinimide (EDC / NHS) coupling chemistry was used to link streptavidin on the surface of the coated LPG. Highly sensitive real-time monitoring of multiple affinity assays between streptavidin and biotinylated bovine serum albumin was performed by following the shift of the LPGs attenuation bands

    Molecular Sensing by Nanoporous Crystalline Polymers

    Get PDF
    Chemical sensors are generally based on the integration of suitable sensitive layers and transducing mechanisms. Although inorganic porous materials can be effective, there is significant interest in the use of polymeric materials because of their easy fabrication process, lower costs and mechanical flexibility. However, porous polymeric absorbents are generally amorphous and hence present poor molecular selectivity and undesired changes of mechanical properties as a consequence of large analyte uptake. In this contribution the structure, properties and some possible applications of sensing polymeric films based on nanoporous crystalline phases, which exhibit all identical nanopores, will be reviewed. The main advantages of crystalline nanoporous polymeric materials with respect to their amorphous counterparts are, besides a higher selectivity, the ability to maintain their physical state as well as geometry, even after large guest uptake (up to 10–15 wt%), and the possibility to control guest diffusivity by controlling the orientation of the host polymeric crystalline phase. The final section of the review also describes the ability of suitable polymeric films to act as chirality sensors, i.e., to sense and memorize the presence of non-racemic volatile organic compounds

    Underwater Acoustic Sensors Based on Fiber Bragg Gratings

    Get PDF
    We report on recent results obtained with a fiber optic hydrophone based on the intensity modulation of the laser light in a FBG (Fiber Bragg Grating) under the influence of the sound pressure. In order to control the behavior of the hydrophone in terms of sensitivity and bandwidth, FBGs have been coated with proper materials, characterized by different elastic modulus and shapes. In particular, new experiments have been carried out using a cylindrical geometry with two different coating, showing that the sensitivity is not influenced by the shape but by the transversal dimension and the material characteristics of the coating

    Tetracycline Residues in Bovine Muscle and Liver Samples from Sicily (Southern Italy) by LC-MS/MS Method: A Six-Year Study

    Get PDF
    We examined a total of 369 bovine liver and muscle samples for the detection of oxytetracycline (OTC), tetracycline (TC), chlortetracycline (CTC), and doxycycline (DOX) residues by implementation and validation of a LC-MS/MS method. The method showed good recovery values between 86% and 92% at three levels of concentrations. The linearity tests revealed r2 > 0.996 for all the tetracyclines examined. Furthermore, the Youden test revealed that the method was robust. Only 14.4% of the samples showed OTC and TC residues in a concentration range of 10.4–40.2 g kg1. No CTC and DOX residues were found in all the samples analyzed. Liver samples showed the highest average values (31.5 20.6 and 21.8 18.9 for OTC and TC, respectively). The results showed a low incidence of TCs in all the samples examined, in comparison with other studies reported in the literature. A significant decrease in TC residues frequency was found from 2013 (p < 0.05). This work reports for the first time epidemiological data on the presence of TC residues in liver and muscle samples of cattle farmed in Sicily (Southern Italy). The very low incidence of TC residues indicates a continuous improvement in farming techniques in Southern Italy, which is essential to ensure consumers’ protection
    corecore