291 research outputs found

    Value of T2 Mapping MRI for Prostate Cancer Detection and Classification.

    Get PDF
    Currently, multi-parametric prostate MRI (mpMRI) consists of a qualitative T <sub>2</sub> , diffusion weighted, and dynamic contrast enhanced imaging. Quantification of T <sub>2</sub> imaging might further standardize PCa detection and support artificial intelligence solutions. To evaluate the value of T <sub>2</sub> mapping to detect prostate cancer (PCa) and to differentiate PCa aggressiveness. Retrospective single center cohort study. Forty-four consecutive patients (mean age 67 years; median PSA 7.9 ng/mL) with mpMRI and verified PCa by subsequent targeted plus systematic MR/ultrasound (US)-fusion biopsy from February 2019 to December 2019. Standardized mpMRI at 3 T with an additionally acquired T <sub>2</sub> mapping sequence. Primary endpoint was the analysis of quantitative T <sub>2</sub> values and contrast differences/ratios (CD/CR) between PCa and benign tissue. Secondary objectives were the correlation between T <sub>2</sub> values, ISUP grade, apparent diffusion coefficient (ADC) value, and PI-RADS, and the evaluation of thresholds for differentiating PCa and clinically significant PCa (csPCa). Mann-Whitney test, Spearman's rank (r <sub>s</sub> ) correlation, receiver operating curves, Youden's index (J), and AUC were performed. Statistical significance was defined as P < 0.05. Median quantitative T <sub>2</sub> values were significantly lower for PCa in PZ (85 msec) and PCa in TZ (75 msec) compared to benign PZ (141 msec) or TZ (97 msec) (P < 0.001). CD/CR between PCa and benign PZ (51.2/1.77), respectively TZ (19.8/1.29), differed significantly (P < 0.001). The best T <sub>2</sub> -mapping threshold for PCa/csPCa detection was for TZ 81/86 msec (J = 0.929/1.0), and for PZ 110 msec (J = 0.834/0.905). Quantitative T <sub>2</sub> values of PCa did not correlate significantly with the ISUP grade (r <sub>s</sub> = 0.186; P = 0.226), ADC value (r <sub>s</sub> = 0.138; P = 0.372), or PI-RADS (r <sub>s</sub> = 0.132; P = 0.392). Quantitative T <sub>2</sub> values could differentiate PCa in TZ and PZ and might support standardization of mpMRI of the prostate. Different thresholds seem to apply for PZ and TZ lesions. However, in the present study quantitative T <sub>2</sub> values were not able to indicate PCa aggressiveness. 2 TECHNICAL EFFICACY: Stage 2

    MRI of the lung (3/3)-current applications and future perspectives

    Get PDF
    BACKGROUND: MRI of the lung is recommended in a number of clinical indications. Having a non-radiation alternative is particularly attractive in children and young subjects, or pregnant women. METHODS: Provided there is sufficient expertise, magnetic resonance imaging (MRI) may be considered as the preferential modality in specific clinical conditions such as cystic fibrosis and acute pulmonary embolism, since additional functional information on respiratory mechanics and regional lung perfusion is provided. In other cases, such as tumours and pneumonia in children, lung MRI may be considered an alternative or adjunct to other modalities with at least similar diagnostic value. RESULTS: In interstitial lung disease, the clinical utility of MRI remains to be proven, but it could provide additional information that will be beneficial in research, or at some stage in clinical practice. Customised protocols for chest imaging combine fast breath-hold acquisitions from a "buffet" of sequences. Having introduced details of imaging protocols in previous articles, the aim of this manuscript is to discuss the advantages and limitations of lung MRI in current clinical practice. CONCLUSION: New developments and future perspectives such as motion-compensated imaging with self-navigated sequences or fast Fourier decomposition MRI for non-contrast enhanced ventilation- and perfusion-weighted imaging of the lung are discussed. Main Messages • MRI evolves as a third lung imaging modality, combining morphological and functional information. • It may be considered first choice in cystic fibrosis and pulmonary embolism of young and pregnant patients. • In other cases (tumours, pneumonia in children), it is an alternative or adjunct to X-ray and CT. • In interstitial lung disease, it serves for research, but the clinical value remains to be proven. • New users are advised to make themselves familiar with the particular advantages and limitations

    Comparison of CT and PET-CT based planning of radiation therapy in locally advanced pancreatic carcinoma

    Get PDF
    Abstract Background To compare computed tomography (CT) with co-registered positron emission tomography-computed tomography (PET-CT) as the basis for delineating gross tumor volume (GTV) in unresectable, locally advanced pancreatic carcinoma (LAPC). Methods Fourteen patients with unresectable LAPC had both CT and PET images acquired. For each patient, two three-dimensional conformal plans were made using the CT and PET-CT fusion data sets. We analyzed differences in treatment plans and doses of radiation to primary tumors and critical organs. Results Changes in GTV delineation were necessary in 5 patients based on PET-CT information. In these patients, the average increase in GTV was 29.7%, due to the incorporation of additional lymph node metastases and extension of the primary tumor beyond that defined by CT. For all patients, the GTVCT versus GTVPET-CT was 92.5 ± 32.3 cm3 versus 104.5 ± 32.6 cm3 (p = 0.009). Toxicity analysis revealed no clinically significant differences between two plans with regard to doses to critical organs. Conclusion Co-registration of PET and CT information in unresectable LAPC may improve the delineation of GTV and theoretically reduce the likelihood of geographic misses.</p

    Whole-body imaging of the musculoskeletal system: the value of MR imaging

    Get PDF
    In clinical practice various modalities are used for whole-body imaging of the musculoskeletal system, including radiography, bone scintigraphy, computed tomography, magnetic resonance imaging (MRI), and positron emission tomography-computed tomography (PET-CT). Multislice CT is far more sensitive than radiographs in the assessment of trabecular and cortical bone destruction and allows for evaluation of fracture risk. The introduction of combined PET-CT scanners has markedly increased diagnostic accuracy for the detection of skeletal metastases compared with PET alone. The unique soft-tissue contrast of MRI enables for precise assessment of bone marrow infiltration and adjacent soft tissue structures so that alterations within the bone marrow may be detected before osseous destruction becomes apparent in CT or metabolic changes occur on bone scintigraphy or PET scan. Improvements in hard- and software, including parallel image acquisition acceleration, have made high resolution whole-body MRI clinically feasible. Whole-body MRI has successfully been applied for bone marrow screening of metastasis and systemic primary bone malignancies, like multiple myeloma. Furthermore, it has recently been proposed for the assessment of systemic bone diseases predisposing for malignancy (e.g., multiple cartilaginous exostoses) and muscle disease (e.g., muscle dystrophy). The following article gives an overview on state-of-the-art whole-body imaging of the musculoskeletal system and highlights present and potential future applications, especially in the field of whole-body MRI

    Role of radiography, MRI and FDG-PET/CT in diagnosing, staging and therapeutical evaluation of patients with multiple myeloma

    Get PDF
    Multiple myeloma is a malignant B-cell neoplasm that involves the skeleton in approximately 80% of the patients. With an average age of 60 years and a 5-years survival of nearly 45% Brenner et al. (Blood 111:2516–2520, 35) the onset is to be classified as occurring still early in life while the disease can be very aggressive and debilitating. In the last decades, several new imaging techniques were introduced. The aim of this review is to compare the different techniques such as radiographic survey, multidetector computed tomography (MDCT), whole-body magnetic resonance imaging (WB-MRI), fluorodeoxyglucose positron emission tomography- (FDG-PET) with or without computed tomography (CT), and 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) scintigraphy. We conclude that both FDG-PET in combination with low-dose CT and whole-body MRI are more sensitive than skeleton X-ray in screening and diagnosing multiple myeloma. WB-MRI allows assessment of bone marrow involvement but cannot detect bone destruction, which might result in overstaging. Moreover, WB-MRI is less suitable in assessing response to therapy than FDG-PET. The combination of PET with low-dose CT can replace the golden standard, conventional skeletal survey. In the clinical practise, this will result in upstaging, due to the higher sensitivity

    Bacterial artificial chromosomes as analytical basis for gene transcriptional machineries

    Get PDF
    Bacterial Artificial Chromosomes (BACs) had been minimal components of various genome-sequencing projects, constituting perfect analytical basis for functional genomics. Here we describe an enhancer screening strategy in which BAC clones that cover any genomic segments of interest are modified to harbor a reporter cassette by transposon tagging, then processed to carry selected combinations of gene regulatory modules by homologous recombination mediated systematic deletions. Such engineered BAC-reporter constructs in bacterial cells are ready for efficient transgenesis in mice to evaluate activities of gene regulatory modules intact or absent in the constructs. By utilizing the strategy, we could speedily identify a critical genomic fragment for spatio-temporally regulated expression of a mouse cadherin gene whose structure is extraordinarily huge and intricate. This BAC-based methodology would hence provide a novel screening platform for gene transcriptional machineries that dynamically fluctuate during development, pathogenesis and/or evolution
    corecore