21 research outputs found

    Rhythm monitoring, success definition, recurrence, and anticoagulation after atrial fibrillation ablation: results from an EHRA survey

    Get PDF
    Atrial fibrillation (AF) is a major challenge for the healthcare field. Pulmonary vein isolation is the most effective treatment for the maintenance of sinus rhythm. However, clinical endpoints for the procedure vary significantly among studies. There is no consensus on the definition of recurrence and no clear roadmap on how to deal with recurrences after a failed ablation. The purpose of this study was to perform a survey in order to show how clinicians currently approach this knowledge gap. An online survey, supported by the European Heart Rhythm Association (EHRA) Scientific Initiatives Committee, was conducted between 1 April 2022 and 8 May 2022. An anonymous questionnaire was disseminated via social media and EHRA newsletters, for clinicians to complete. This consisted of 18 multiple-choice questions regarding rhythm monitoring, definitions of a successful ablation, clinical practices after a failed AF ablation, and the continuance of anticoagulation. A total of 107 replies were collected across Europe. Most respondents (82%) perform routine monitoring for AF recurrences after ablation, with 51% of them preferring a long-term monitoring strategy. Cost was reported to have an impact on the choice of monitoring strategy. Self-screening was recommended by most (71%) of the respondents. The combination of absence of symptoms and recorded AF was the definition of success for most (83%) of the respondents. Cessation of anticoagulation after ablation was an option mostly for patients with paroxysmal AF and a low CHA2DS2-VASc score. The majority of physicians perform routine monitoring after AF ablation. For most physicians, the combination of the absence of symptoms and electrocardiographic endpoints defines a successful result after AF ablation

    Comparison of procedural efficacy and biophysical parameters between two competing cryoballoon technologies for pulmonary vein isolation: Insights from an initial multicenter experience

    Get PDF
    Introduction: Recently a novel cryoballoon system (POLARx, Boston Scientific) became available for the treatment of atrial fibrillation. This cryoballoon is comparable with Arctic Front Advance Pro (AFA-Pro, Medtronic), however, it maintains a constant balloon pressure. We compared the procedural efficacy and biophysical characteristics of both systems. Methods: One hundred and ten consecutive patients who underwent first-time cryoballoon ablation (POLARx: n = 57; AFA-Pro: n = 53) were included in this prospective cohort study. Results: Acute isolation was achieved in 99.8% of all pulmonary veins (POLARx: 99.5% vs. AFA-Pro: 100%, p = 1.00). Total procedure time (81 vs. 67 min, p <.001) and balloon in body time (51 vs. 35 min, p <.001) were longer with POLARx. After a learning curve, these times were similar. Cryoablation with POLARx was associated with shorter time to balloon temperature −30°C (27 vs. 31 s, p <.001) and −40°C (32 vs. 54 s, p <.001), lower balloon nadir temperature (−55°C vs. −47°C, p <.001), and longer thawing time till 0°C (16 vs. 9 s, p <.001). There were no differences in time-to-isolation (TTI; POLARx: 45 s vs. AFA-Pro 43 s, p =.441), however, POLARx was associated with a lower balloon temperature at TTI (−46°C vs. −37°C, p <.001). Factors associated with acute isolation differed between groups. The incidence of phrenic nerve palsy was comparable (POLARx: 3.5% vs. AFA-Pro: 3.7%). Conclusion: The novel cryoballoon is comparable to AFA-Pro and requires only a short learning curve to get used to the slightly different handling. It was associated with faster cooling rates and lower

    Multi-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF).

    Get PDF
    AIMS Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement

    Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study

    Get PDF
    Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.Peer reviewe

    Conduction system pacing in everyday clinical practice: EHRA physician survey

    No full text
    With the increasing interest in conduction system pacing (CSP) over the last few years and the inclusion of this treatment modality in the current guidelines, our aim was to provide a snapshot of current practice across Europe. An online questionnaire was sent to physicians participating in the European Heart Rhythm Association research network as well as to national societies and over social media. Data on previous experience with CSP, current indications, preferred tools, unmet needs, and perceptions for the future are reported and discussed

    Serum Catestatin Concentrations Are Increased in Patients with Atrial Fibrillation

    No full text
    The autonomic nervous system is crucial in initiating and maintaining atrial fibrillation (AF). Catestatin is a multipurpose peptide that regulates cardiovascular systems and reduces harmful, excessive activity of the sympathetic nervous system by blocking the release of catecholamines. We aimed to determine whether serum catestatin concentrations are associated with AF severity, duration indices, and various clinical and laboratory indicators in these individuals to better define the clinical value of catestatin in patients with AF. The present single center study enrolled 73 participants with AF and 72 healthy age-matched controls. Serum catestatin concentrations were markedly higher in AF patients than controls (14.11 (10.21–26.02) ng/mL vs. 10.93 (5.70–20.01) ng/mL, p = 0.013). Furthermore, patients with a more severe form of AF had significantly higher serum catestatin (17.56 (12.80–40.35) vs. 10.98 (8.38–20.91) ng/mL, p = 0.001). Patients with higher CHA2DS2-VASc scores (17.58 (11.89–37.87) vs. 13.02 (8.47–22.75) ng/mL, p = 0.034) and higher NT-proBNP levels (17.58 (IQR 13.91–34.62) vs. 13.23 (IQR 9.04–22.61), p = 0.036) had significantly higher serum catestatin concentrations. Finally, AF duration correlated negatively with serum catestatin levels (r = −0.348, p = 0.003). The results of the present study implicate the promising role of catestatin in the intricate pathophysiology of AF, which should be explored in future research

    Management of ventricular tachycardias: insights on centre settings, procedural workflow, endpoints, and implementation of guidelines-results from an EHRA survey.

    No full text
    Ventricular tachycardia (VT), and its occurrence, is still one of the main reasons for sudden cardiac death and, therefore, for increased mortality and morbidity foremost in patients with structural heart [Kahle A-K, Jungen C, Alken F-A, Scherschel K, Willems S, Pürerfellner H et al. Management of ventricular tachycardia in patients with ischaemic cardiomyopathy: contemporary armamentarium. Europace 2022;24:538-51]. Catheter ablation has become a safe and effective treatment option in patients with recurrent VT [Cronin EM, Bogun FM, Maury P, Peichl P, Chen M, Namboodiri N et al. 2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias. Heart Rhythm 2020;17:e2-154]. Previous and current guidelines provide guidance on indication for VT ablation and risk assessment and evaluation of underlying disease. However, no uniform recommendation is provided regarding procedural strategies, timing of ablation, and centre setting. Therefore, these specifics seem to differ largely, and recent data are sparse. This physician-based European Heart Rhythm Association survey aims to deliver insights on not only infrastructural settings but also procedural specifics, applied technologies, ablation strategies, and procedural endpoints. Therefore, these findings might deliver a real-world scenario of VT management and potentially are of guidance for other centres

    Effectiveness and safety of a single freeze strategy of cryoballoon ablation of atrial fibrillation: an EHRA systematic review and meta-analysis.

    Get PDF
    To conduct a systematic review and meta-analysis to compare the effectiveness and safety of cryoballoon ablation of atrial fibrillation (AF) performed using a single freeze strategy in comparison to an empiric double ('bonus') freeze strategy. We systematically searched MEDLINE, EMBASE, and CENTRAL databases from inception to 12 July 2020, for prospective and retrospective studies of patients undergoing cryoballoon for paroxysmal or persistent AF comparing a single vs. bonus freeze strategy. The main outcome was atrial arrhythmia-free survival and eligible studies required at least 12 months of follow-up; the primary safety outcome was a composite of all complications. Study quality was assessed using the Cochrane risk of bias tool and the Newcastle-Ottawa Scale. Thirteen studies (3 randomized controlled trials and 10 observational studies) comprising 3163 patients were eligible for inclusion (64% males, 71.5% paroxysmal AF, mean CHA2DS2-VASc score 1.3 ± 0.9). There was no significant difference in pooled effectiveness between single freeze strategy compared to double freeze strategy [relative risk (RR) 1.03; 95% confidence interval (CI): 0.98-1.07; I2 = 0%]. Single freeze procedures were associated with a significantly lower adverse event rate (RR 0.72; 95% CI: 0.53-0.98; I2 = 0%) and shorter average procedure time (90 ± 27 min vs. 121 ± 36 min, P < 0.001). A trend for lower risk of persistent phrenic nerve palsy was observed (RR 0.61; 95% CI: 0.37-1.01; I2 = 0%). The quality of included studies was moderate/good, with no evidence of significant publication bias. Single freeze strategy for cryoballoon of AF is as effective as an empiric double ('bonus') freeze strategy while appearing safer and probably quicker (PROSPERO registration number CRD42020158696)
    corecore