48 research outputs found
Behaviour of the foramen ovale flow in fetuses with intrauterine growth restriction
Foramen ovale (FO) flow may be altered in IUGR. .is study was designed to test this hypothesis. Methods. Forty pregnant women (24–38 weeks) were divided into 3 groups: group I (IUGR), group II (adequate growth and maternal hypertension), and group III (normal controls). Impedance across the FO was assessed by the FO pulsatility index (FOPI): (systolic velocity − presystolic velocity)/mean velocity. Statistical analysis utilized ANOVA, Tukey test, and ROC curves. Results. Mean FOPI in IUGR fetuses (n=15) was 3.70 ± 0.99 (3.15–4.26); in the group II (n=12), it was 2.84 ± 0.69 (2.40–3.28), and in the group III (n=13), it was 2.77 ± 0.44 (2.50–3.04) (p=0.004). FOPI and UtA RI were correlated (r= 0.375, p= 0.017), as well as FOPI and UA RI (r= 0.356, p= 0.024) and, inversely, FOPI and MCA RI (r= −0.359, p= 0.023). Conclusions. .e FO flow pulsatility index is increased in fetuses with IUGR, probably as a result of impaired left ventricular diastolic functio
Adequacy of one earth-sheltered home to thermal comfort and energy efficiency
Neste trabalho é dada continuação a um estudo que simulou o desempenho termoenergético de uma casa protegida pela terra, com o objetivo de adequar a residência ao conforto térmico e eficiência energética. A casa é unifamiliar e parcialmente encoberta por terra, situada na região metropolitana de Porto Alegre, no estado do Rio Grande do Sul. A camada de terra que encobre parte da casa atua como capacitor térmico, diminuindo a amplitude da variação de temperatura dentro da casa. Foram utilizados como instrumentos de melhoria nas condições de conforto e eficiência energética: Clarabóias que ajudam no aproveitamento de iluminação e ventilação natural nos ambientes que não possuem janelas, proteções solares horizontais que auxiliam na uniformização da luz natural incidente, tubos de ventilação para a ventilação cruzada e efeito chaminé nos ambientes que não têm as clarabóias, chaminé para retirar o calor dissipado pela geladeira na cozinha durante o verão, isolamento térmico no envoltório da residência, sistema de coleta de água da chuva, coletores solares e fogão à lenha para o aquecimento de água nos banhos e do ambiente. Para desenvolver este trabalho foram utilizados os softwares de desenho DraftSight e SketchUp junto com o plug-in OpenStudio, e o de simulação de desempenho energético EnergyPlus, bem como os dados climáticos de Porto Alegre. Apenas em 3,32 % do total de horas do ano a edificação esteve fora da faixa de conforto térmico considerada para a temperatura operativa (19º a 28ºC), o sistema de coleta de água da chuva supriu os sanitários da casa durante 70 % das horas do ano e o sistema de aquecimento se mostrou satisfatório utilizando somente energias renováveis.This work is a continuation of a study that simulated the thermal energy performance of an earth-sheltered home, in order to adapt the residence to thermal comfort and energy efficiency. It is a single-family house and is partially underground, located in Porto Alegre, state of Rio Grande do Sul. The layer of earth that covers part of the house acts as a thermal capacitor, reducing the range of temperature variation inside the house. Were used as tools of improving comfort and energy efficiency: Skylights to improve natural lighting and ventilation in rooms that do not have windows, horizontal blinds that help homogenize the incident natural light, ventilation tubes for cross ventilation and stack effect in rooms that do not have skylights, chimney to remove the heat dissipated by the refrigerator in the kitchen during the summer, insulation, rainwater collection system, solar panels and wood stove for heating water in the baths and rooms. To develop this work, DraftSight and SketchUp with plug-in OpenStudio were used as drawing softwares and EnergyPlus as energy performance simulation software. Climatic data of Porto Alegre also were used in this work. Only in 3.32% of the total hours of the year the building was out of thermal comfort range considered (19 º to 28 º C), the rainwater collection system supplied the house for 70% of the hours of the year and the heating system proved satisfactory comfort using only renewable energy
Adequacy of one earth-sheltered home to thermal comfort and energy efficiency
Neste trabalho é dada continuação a um estudo que simulou o desempenho termoenergético de uma casa protegida pela terra, com o objetivo de adequar a residência ao conforto térmico e eficiência energética. A casa é unifamiliar e parcialmente encoberta por terra, situada na região metropolitana de Porto Alegre, no estado do Rio Grande do Sul. A camada de terra que encobre parte da casa atua como capacitor térmico, diminuindo a amplitude da variação de temperatura dentro da casa. Foram utilizados como instrumentos de melhoria nas condições de conforto e eficiência energética: Clarabóias que ajudam no aproveitamento de iluminação e ventilação natural nos ambientes que não possuem janelas, proteções solares horizontais que auxiliam na uniformização da luz natural incidente, tubos de ventilação para a ventilação cruzada e efeito chaminé nos ambientes que não têm as clarabóias, chaminé para retirar o calor dissipado pela geladeira na cozinha durante o verão, isolamento térmico no envoltório da residência, sistema de coleta de água da chuva, coletores solares e fogão à lenha para o aquecimento de água nos banhos e do ambiente. Para desenvolver este trabalho foram utilizados os softwares de desenho DraftSight e SketchUp junto com o plug-in OpenStudio, e o de simulação de desempenho energético EnergyPlus, bem como os dados climáticos de Porto Alegre. Apenas em 3,32 % do total de horas do ano a edificação esteve fora da faixa de conforto térmico considerada para a temperatura operativa (19º a 28ºC), o sistema de coleta de água da chuva supriu os sanitários da casa durante 70 % das horas do ano e o sistema de aquecimento se mostrou satisfatório utilizando somente energias renováveis.This work is a continuation of a study that simulated the thermal energy performance of an earth-sheltered home, in order to adapt the residence to thermal comfort and energy efficiency. It is a single-family house and is partially underground, located in Porto Alegre, state of Rio Grande do Sul. The layer of earth that covers part of the house acts as a thermal capacitor, reducing the range of temperature variation inside the house. Were used as tools of improving comfort and energy efficiency: Skylights to improve natural lighting and ventilation in rooms that do not have windows, horizontal blinds that help homogenize the incident natural light, ventilation tubes for cross ventilation and stack effect in rooms that do not have skylights, chimney to remove the heat dissipated by the refrigerator in the kitchen during the summer, insulation, rainwater collection system, solar panels and wood stove for heating water in the baths and rooms. To develop this work, DraftSight and SketchUp with plug-in OpenStudio were used as drawing softwares and EnergyPlus as energy performance simulation software. Climatic data of Porto Alegre also were used in this work. Only in 3.32% of the total hours of the year the building was out of thermal comfort range considered (19 º to 28 º C), the rainwater collection system supplied the house for 70% of the hours of the year and the heating system proved satisfactory comfort using only renewable energy
Mobility of the Septum primum does not depend on the foramen ovale diameter in normal fetuses
OBJETIVO: Testar a hipótese de que existe correlação entre o diâmetro máximo diastólico do forame oval e o Ãndice de excursão do septum primum em fetos normais. MÉTODOS: Foram examinados, por ecocardiografia, 102 fetos normais de gestantes com idades gestacionais entre 20 e 40 semanas. O diâmetro do forame oval e a excursão máxima do septum primum foram medidos num corte de 4 câmaras. Na análise dos dados utilizou-se o coeficiente de correlação de Pearson. RESULTADOS: A média do forame oval foi de 5,06 ± 1,29 mm; a da excursão máxima do septum primum de 5,42 ± 1,41 mm; a do átrio esquerdo 11,47 ± 2,76 mm e a do Ãndice de excursão 0,48 ± 0,09. A relação média FO/IE foi de 11,35 ± 3,94 mm. Não houve correlação FO/IE (r = -0,03) e observou-se correlação fraca do forame oval com o átrio esquerdo (r = 0,031) e com a excursão do septum primum (r = 0,21). CONCLUSÃO: A mobilidade do septum primum não depende do diâmetro do forame oval em fetos normais, sugerindo que as modificações da sua excursão diastólica não decorram do grau de abertura interatrial.OBJECTIVE: To test the hypothesis that a correlation exists between the maximum foramen ovale diastolic diameter and the excursion index (EI) of the septum primum in normal fetuses. METHODS: One hundred and two normal fetuses with gestational ages ranging from 20 to 40 weeks were submitted to echocardiography. The foramen ovale diameter and the "maximal excursion" of the septum primum were measured in a 4-chamber view. The data were analyzed by Pearson's correlation coefficient. RESULTS: The mean foramen ovale (FO) diameter was 5.06 ± 1.29 mm; the maximal excursion of the septum primum was 5.42 ± 1.41 mm; the left atrium diameter 11.47 ± 2.76 mm; the septum primum "excursion index" was 0.48 ± 0.09. Mean FO/EI ratio was 11.35 ± 3.94 mm. No FO/EI correlation (r = -0.03) existed, and a weak foramen ovale/left atrium correlation (r = 0.31) was observed, as well as a weak foramen ovale/excursion of septum primum correlation (r = 0.21). CONCLUSION: Septum primum mobility does not depend on the foramen ovale diameter in normal fetuses, suggesting that the modifications of its diastolic displacement is not influenced by the size of the interatrial opening
Maternal Restriction of Polyphenols and Fetal Ductal Dynamics in Normal Pregnancy: An Open Clinical Trial
FUNDAMENTOS: Recentemente demonstramos reversão da constrição ductal fetal após redução da ingesta materna de alimentos ricos em polifenóis (ARP), por sua ação inibidora da sÃntese das prostaglandinas. OBJETIVOS: Testar a hipótese de que fetos normais no 3º trimestre também melhoram a dinâmica ductal após restrição materna de polifenóis. MÉTODOS: Ensaio clÃnico aberto com 46 fetos com idade gestacional (IG) > 28 semanas submetidos a dois estudos Dopplerecocardiográficos com intervalo de duas semanas, sendo os examinadores cegados para os hábitos alimentares maternos. Um questionário de frequência alimentar validado para esse objetivo foi aplicado e uma dieta com alimentos pobres em polifenóis (< 30 mg/100 mg) foi orientada. Um grupo controle de 26 fetos no 3º trimestre foi submetido ao mesmo protocolo. Utilizou-se o teste-t para amostras independentes. RESULTADOS: A IG média foi 33 ± 2 semanas. A média do consumo materno diário de polifenóis (CMDP) foi 1277 mg, caindo para 126 mg após orientação (p = 0,0001). Ocorreu diminuição significativa nas Velocidades Ductais Sistólica (VSD) e Diastólica (VDD) e na relação dos diâmetros ventriculares (VD/VE), assim como aumento do Ãndice de pulsatilidade (IP) [VSD = 1,2 ± 0,4 m/s (0,7-1,6) para 0,9 ± 0,3 m/s (0,6-1,3) (p = 0,018);VDD = 0,21 ± 0,09 m/s (0,15-0,32) para 0,18 ± 0,06 m/s (0,11-0,25) (p = 0,016); relação VD/VE = 1,3 ± 0,2 (0,9-1,4) para 1,1 ± 0,2 (0,8 - 1,3) (p = 0,004); IP do ducto = 2,2 ± 0,03 (2,0-2,7) para 2,4 ± 0,4 (2,2-2,9) (p = 0,04)]. A IG média dos controles foi de 32 ± 4 semanas, não ocorrendo diferenças significativas no CMDP, nas velocidades ductais, no IP do ducto e na relação VD/VE. CONCLUSÃO: A restrição da ingesta de alimentos ricos em polifenóis no 3º trimestre por duas semanas melhora a dinâmica do fluxo no ducto arterioso fetal e as dimensões do VD