466 research outputs found

    Occurrence of tympanic bone spicules and bone crests in domestic cats

    Get PDF
    Small and hyperostotic tympanic bone spicules (STBS and HTBS) extending from the tympanic wall or from the septum bullae into the tympanic cavity have been described in large feline species such as Siberian tigers or African lions and in canids such as dogs, red foxes and wolves. Detailed descriptions of prevalence, location and orientation were performed for dogs and African lions by means of necropsy and conventional computed tomography (cCT). Aims of the current study were to describe same characteristics for domestic cats by means of microcomputed tomography (”CT) and cCT. A total of 15 cats or rather 30 ears were examined. Furthermore, new bone formations extending into the tympanic cavity shaped like small lamellae were found and named “tympanic bone crests” (TBCs). The registered phenomenon of a thickened tympanic wall in some cats was named “tympanic wall thickening” (TWT). STBS appeared in 43% of the ears being bilateral in 44% of the cases, whereas HTBS appeared in one ear. TBC was present in 33% of the ears with a bilateral prevalence of 67%, and TWT could be detected in 13% of the ears. The mentioned structures are just barely or not at all detectable with cCT; therefore, ”CT is necessary for an identification and detailed description. The origin and the factors inducing the development of examined phenomena are unknown, and it is hypothesized that the occurrence can be assessed as anatomical norm variations

    In Vivo Corrosion of Two Novel Magnesium Alloys ZEK100 and AX30 and Their Mechanical Suitability as Biodegradable Implants

    Get PDF
    In magnesium alloys, the components used modify the alloy properties. For magnesium implants in contact with bone, rare earths alloys are commonly examined. These were shown to have a higher corrosion resistance than other alloys and a high mechanical strength, but their exact composition is hard to predict. Therefore a reduction of their content could be favorable. The alloys ZEK100 and AX30 have a reduced content or contain no rare earths at all. The aim of the study was to investigate their in vivo degradation and to assess the suitability of the in vivo ÎŒCT for the examination of their corrosion. Implants were inserted in rabbit tibiae. Clinical examinations, X-rays and in vivo ÎŒCT scans were done regularly. Afterwards implants were analyzed with REM, electron dispersive X-ray (EDX), weighing and mechanical testing. The in vivo ÎŒCT is of great advantage, because it allows a quantification of the corrosion rate and qualitative 3D assessment of the corrosion morphology. The location of the implant has a remarkable effect on the corrosion rate. Due to its mechanical characteristics and its corrosion behavior, ZEK100 was judged to be suitable, while AX30, which displays favorable degradation behavior, has too little mechanical strength for applications in weight bearing bones

    Protein Interaction Networks Link Schizophrenia Risk Loci to Synaptic Function.

    Get PDF
    Schizophrenia is a severe and highly heritable psychiatric disorder affecting approximately 1% of the population. Genome-wide association studies have identified 108 independent genetic loci with genome-wide significance but their functional importance has yet to be elucidated. Here, we develop a novel strategy based on network analysis of protein-protein interactions (PPI) to infer biological function associated with variants most strongly linked to illness risk. We show that the schizophrenia loci are strongly linked to synaptic transmission (P FWE < .001) and ion transmembrane transport (P FWE = .03), but not to ontological categories previously found to be shared across psychiatric illnesses. We demonstrate that brain expression of risk-linked genes within the identified processes is strongly modulated during birth and identify a set of synaptic genes consistently changed across multiple brain regions of adult schizophrenia patients. These results suggest synaptic function as a developmentally determined schizophrenia process supported by the illness's most associated genetic variants and their PPI networks. The implicated genes may be valuable targets for mechanistic experiments and future drug development approaches

    Introduction of a bone-centered three-dimensional coordinate system enables computed tomographic canine femoral angle measurements independent of positioning

    Get PDF
    Introduction: Measurement of torsional deformities and varus alignment in the canine femur is clinically and surgically important but difficult. Computed tomography (CT) generates true three-dimensional (3D) information and is used to overcome the limitations of radiography. The 3D CT images can be rotated freely, but the final view for angle measurements remains a subjective variable decision, especially in severe and complex angular and torsional deformities. The aim of this study was the development of a technique to measure femoral angles in a truly three-dimensional way, independent of femoral positioning. Methods: To be able to set reference points in any image and at arbitrary positions of the CT series, the 3D coordinates of the reference points were used for mathematical calculation of the angle measurements using the 3D medical imaging Software VoXim¼. Anatomical reference points were described in multiplanar reconstructions and volume rendering CT. A 3D bone-centered coordinate system was introduced and aligned with the anatomical planes of the femur. For torsion angle measurements, the transverse projection plane was mathematically defined by orthogonality to the longitudinal diaphyseal axis. For varus angle measurements, the dorsal plane was defined by a femoral retrocondylar axis. Independence positioning was tested by comparison of angle measurement results in repeated scans of 13 femur bones in different parallel and two double oblique (15/45°) positions in the gantry. Femoralvarus (or valgus), neck version (torsion), and inclination angles were measured, each in two variations. Results: Resulting mean differences ranged between –0.9° and 1.3° for all six determined types of angles and in a difference of <1° for 17 out of 18 comparisons by subtraction of the mean angles between different positions, with one outlier of 1.3°. Intra- and inter-observer agreements determined by repeated measurements resulted in coefficients of variation for repeated measurements between 0.2 and 13.5%. Discussion: The introduction of a bone-centered 3D coordinate system and mathematical definition of projection planes enabled 3D CT measurements of canine femoral varus and neck version and inclination angles. Agreement between angular measurements results of bones scanned in different positions on the CT table demonstrated that the technique is independent of femoral positioning

    Directed coupling in multi-brain networks underlies generalized synchrony during social exchange

    Get PDF
    Advances in social neuroscience have made neural signatures of social exchange measurable simultaneously across people. This has identified brain regions differentially active during social interaction between human dyads, but the underlying systems-level mechanisms are incompletely understood. This paper introduces dynamic causal modeling and Bayesian model comparison to assess the causal and directed connectivity between two brains in the context of hyperscanning (h-DCM). In this setting, correlated neuronal responses become the data features that have to be explained by models with and without between-brain (effective) connections. Connections between brains can be understood in the context of generalized synchrony, which explains how dynamical systems become synchronized when they are coupled to each another. Under generalized synchrony, each brain state can be predicted by the other brain or a mixture of both. Our results show that effective connectivity between brains is not a feature within dyads per se but emerges selectively during social exchange. We demonstrate a causal impact of the sender's brain activity on the receiver of information, which explains previous reports of two-brain synchrony. We discuss the implications of this work; in particular, how characterizing generalized synchrony enables the discovery of between-brain connections in any social contact, and the advantage of h-DCM in studying brain function on the subject level, dyadic level, and group level within a directed model of (between) brain function

    Computed tomographic angular measurements using a bone-centered three-dimensional coordinate system are accurate in a femoral torsional deformity model and precise in clinical canine patients

    Get PDF
    IntroductionIn small animal orthopedics, angular measurements in the canine femur are often applied in clinical patients with bone deformities and especially in complex and severe cases. Computed tomography (CT) has been shown to be more precise and accurate than two-dimensional radiography, and several methods are described. Measurement techniques evaluated in normal bones must prove accuracy in deformed bones in clinical settings.ObjectivesThe goals of our study were to evaluate the accuracy of canine femoral torsion angle measurements in a femoral torsional deformity model and to test repeatability and reproducibility of canine femoral neck inclination, torsion, and varus angle measurements in CT datasets of dogs applying a CT-based technique using a three-dimensional (3D) bone-centered coordinate system.Materials and methodsFor precision testing, femoral torsion, femoral neck inclination, and femoral varus angles were measured in CT data of 68 canine hind limbs by two operators, and their results were compared. For accuracy testing, a femoral torsional deformity model was preset from 0° to +/−90° with a goniometer and scanned. Torsion angles were measured in the CT data and compared to the preset value.ResultsIn the femoral torsion model, the Bland–Altman plots demonstrated a mean difference of 2.11°, and the Passing–Bablok analysis demonstrated a correlation between goniometer and CT-based measurements. In the clinical CT scans, intra- and interobserver agreement resulted in coefficients of variation for repeated measurements (%) between 1.99 and 8.26 for the femoral torsion, between 0.59 and 4.47 for the femoral neck inclination, and between 1.06 and 5.15 for the femoral varus angles.DiscussionEvaluation of femoral malformations with torsional deformities is the target area of this technique. Further studies are required to assess its value in different types, degrees, and combinations of osseous deformities and to establish normal reference values and guidelines for corrective osteotomies.ConclusionBased on the results of this study, the accuracy of the torsion angle measurements and the precision of inclination, torsion, and the varus angle measurements were considered acceptable for clinical application
    • 

    corecore