27 research outputs found

    The Natural History of Asymptomatic Ventricular Pre-Excitation A Long-Term Prospective Follow-Up Study of 184 Asymptomatic Children

    Get PDF
    ObjectivesThe aim of this study was to describe the natural history of asymptomatic ventricular pre-excitation in children and to determine predictors of potentially life-threatening arrhythmic events.BackgroundSudden death can be the first clinical manifestation in asymptomatic children with ventricular pre-excitation, but reduction of its incidence by prophylactic ablation requires the identification of subjects at high risk.MethodsBetween 1995 and 2005 we prospectively collected clinical and electrophysiologic data from 184 children (66% male; median age 10 years; range 8 to 12 years) with asymptomatic ventricular pre-excitation on the electrocardiogram. After electrophysiologic testing, subjects were followed as outpatients taking no medications. The primary end point of the study was the occurrence of arrhythmic events. Predictors of potentially life-threatening arrhythmias were analyzed.ResultsOver a median follow-up of 57 months (min/max 32/90 months) after electrophysiologic testing, 133 children (mean age 10 years; range 8 to 12 years) did not experience arrhythmic events, remaining totally asymptomatic, while 51 children had within 20 months (min/max 8/60 months) a first arrhythmic event, which was potentially life-threatening in 19 of them (mean age 10 years; range 10 to 14 years). Life-threatening tachyarrhythmias resulted in cardiac arrest (3 patients), syncope (3 patients), atypical symptoms (8 patients), or minimal symptoms (5 patients). Univariate analysis identified tachyarrhythmia inducibility (p < 0.001), anterograde refractory period of accessory pathways (APERP) ≤240 ms (p < 0.001), and multiple accessory pathways (p < 0.001) as risk factors for potentially life-threatening arrhythmic events. Independent predictors by multivariate analysis were APERP (p = 0.001) and multiple accessory pathway (p = 0.001).ConclusionsThese findings are potentially relevant in terms of early identification of high-risk asymptomatic children with ventricular pre-excitation. Subjects with short APERPs and multiple pathways are at higher risk of developing life-threatening arrhythmic events and are the best candidates for prophylactic ablation

    EP Testing in Asymptomatic Brugada Patients with Recurrent Palpitations. Just do it

    Get PDF
    Brugada syndrome is a rare heritable arrhythmogenic disease characterized by a coved ST segment elevation in the right precordial leads and by an increased risk of sudden cardiac arrest as a result of polymorphic ventricular tachyarrhythmias or ventricular fibrillation (1). Although implantable cardioverter defibrillators are considered to be the main therapy in patients with a history of ventricular arrhythmias or syncope, risk stratification in cases without these symptoms remains controversial. Patients with confirmed Brugada pattern and a history of palpitations without major events should be scheduled for risk stratification. Even though its value has been questioned, inducibility of VTs/VF at programmed electric stimulation is widely used to select candidates to receive a prophylactic implantable cardiac defibrillator in these categories. Herein, we report a patient with type I Electrocardiogram (ECG) pattern induced at the Ajmaline test and a family history of sudden cardiac death who had episodes of palpitations. We describe and discuss our management proving the importance of complete electrophysiological testing in the setting of Brugada asymptomatic patients' risk stratification

    Electrocardiographic findings in patients with arrhythmogenic cardiomyopathy and right bundle branch block ventricular tachycardia

    Full text link
    AIMS: Little is known about patients with right bundle branch block (RBBB)-ventricular tachycardia (VT) and arrhythmogenic cardiomyopathy (ACM). Our aims were: (i) to describe electrocardiogram (ECG) characteristics of sinus rhythm (SR) and VT; (ii) to correlate SR with RBBB-VT ECGs; and (iii) to compare VT ECGs with electro-anatomic mapping (EAM) data. METHODS AND RESULTS: From the European Survey on ACM, 70 patients with spontaneous RBBB-VT were included. Putative left ventricular (LV) sites of origin (SOOs) were estimated with a VT-axis-derived methodology and confirmed by EAM data when available.  Overall, 49 (70%) patients met definite Task Force Criteria. Low QRS voltage predominated in lateral leads (n = 37, 55%), but QRS fragmentation was more frequent in inferior leads (n = 15, 23%). T-wave inversion (TWI) was equally frequent in inferior (n = 28, 42%) and lateral (n = 27, 40%) leads. TWI in inferior leads was associated with reduced LV ejection fraction (LVEF; 46 ± 10 vs. 53 ± 8, P = 0.02). Regarding SOOs, the inferior wall harboured 31 (46%) SOOs, followed by the lateral wall (n = 17, 25%), the anterior wall (n = 15, 22%), and the septum (n = 4, 6%). EAM data were available for 16 patients and showed good concordance with the putative SOOs. In all patients with superior-axis RBBB-VT who underwent endo-epicardial VT activation mapping, VT originated from the LV. CONCLUSIONS: In patients with ACM and RBBB-VT, RBBB-VTs originated mainly from the inferior and lateral LV walls. SR depolarization and repolarization abnormalities were frequent and associated with underlying variants

    Canagliflozin and renal outcomes in type 2 diabetes and nephropathy

    Get PDF
    BACKGROUND Type 2 diabetes mellitus is the leading cause of kidney failure worldwide, but few effective long-term treatments are available. In cardiovascular trials of inhibitors of sodium–glucose cotransporter 2 (SGLT2), exploratory results have suggested that such drugs may improve renal outcomes in patients with type 2 diabetes. METHODS In this double-blind, randomized trial, we assigned patients with type 2 diabetes and albuminuric chronic kidney disease to receive canagliflozin, an oral SGLT2 inhibitor, at a dose of 100 mg daily or placebo. All the patients had an estimated glomerular filtration rate (GFR) of 30 to &lt;90 ml per minute per 1.73 m2 of body-surface area and albuminuria (ratio of albumin [mg] to creatinine [g], &gt;300 to 5000) and were treated with renin–angiotensin system blockade. The primary outcome was a composite of end-stage kidney disease (dialysis, transplantation, or a sustained estimated GFR of &lt;15 ml per minute per 1.73 m2), a doubling of the serum creatinine level, or death from renal or cardiovascular causes. Prespecified secondary outcomes were tested hierarchically. RESULTS The trial was stopped early after a planned interim analysis on the recommendation of the data and safety monitoring committee. At that time, 4401 patients had undergone randomization, with a median follow-up of 2.62 years. The relative risk of the primary outcome was 30% lower in the canagliflozin group than in the placebo group, with event rates of 43.2 and 61.2 per 1000 patient-years, respectively (hazard ratio, 0.70; 95% confidence interval [CI], 0.59 to 0.82; P=0.00001). The relative risk of the renal-specific composite of end-stage kidney disease, a doubling of the creatinine level, or death from renal causes was lower by 34% (hazard ratio, 0.66; 95% CI, 0.53 to 0.81; P&lt;0.001), and the relative risk of end-stage kidney disease was lower by 32% (hazard ratio, 0.68; 95% CI, 0.54 to 0.86; P=0.002). The canagliflozin group also had a lower risk of cardiovascular death, myocardial infarction, or stroke (hazard ratio, 0.80; 95% CI, 0.67 to 0.95; P=0.01) and hospitalization for heart failure (hazard ratio, 0.61; 95% CI, 0.47 to 0.80; P&lt;0.001). There were no significant differences in rates of amputation or fracture. CONCLUSIONS In patients with type 2 diabetes and kidney disease, the risk of kidney failure and cardiovascular events was lower in the canagliflozin group than in the placebo group at a median follow-up of 2.62 years

    Different transseptal puncture for different procedures: Optimization of left atrial catheterization guided by transesophageal echocardiography

    No full text
    Background: Left atrial catheterization through transseptal puncture is frequently performed in cardiac catheterization procedures. Appropriate transseptal puncture is critical to achieve procedural success. Aims: The aim of the study is to evaluate the feasibility of selective transseptal punctures, using a modified radiofrequency (RF) transseptal needle and transesophageal echocardiography (TEE), in different types of procedures that require specific sites of left atrial catheterization. Setting and Design: This was an observational trial in a cardiac catheterization laboratory of a teaching hospital. Materials and Methods: Patients undergoing different percutaneous procedures requiring atrial transseptal puncture such as atrial fibrillation (AF) ablation, left atrial appendage (LAA) occlusion, and mitral valve repair were included in the study. All procedures were guided by TEE and an RF transseptal needle targeting a specific region of the septum to perform the puncture. Statistical Analysis: The statistical analysis was descriptive only. Results: RF-assisted transseptal punctures were performed in six consecutive patients who underwent AF ablation (two patients), LAA closure (two patients), and mitral valve repair (two patients). In all patients, transseptal punctures were performed successfully at the desired site. No adverse events or complications were observed. Conclusions: Selective transseptal puncture, using TEE and an RF needle, is a feasible technique that can be used in multiple approaches requiring a precise site of access for left atrial catheterization

    Breaking degeneracies with the Sunyaev-Zeldovich full bispectrum

    No full text
    Non-Gaussian (NG) statistics of the thermal Sunyaev-Zeldovich (tSZ) effect carry significant information which is not contained in the power spectrum. Here, we perform a joint Fisher analysis of the tSZ power spectrum and bispectrum to verify how much the full bispectrum can contribute to improve parameter constraints. We go beyond similar studies of this kind in several respects: first of all, we include the complete power spectrum and bispectrum (auto- and cross-) covariance in the analysis, computing all NG contributions; furthermore we consider a multi-component foreground scenario and model the effects of component separation in the forecasts; finally, we consider an extended set of both cosmological and intra-cluster medium parameters. We show that the tSZ bispectrum is very efficient at breaking parameter degeneracies, making it able to produce even stronger cosmological constraints than the tSZ power spectrum: e.g. the standard deviation on σ8\sigma_8 shrinks from σPS(σ8)=0.35\sigma^\text{PS}(\sigma_8)=0.35 to σBS(σ8)=0.065\sigma^\text{BS}(\sigma_8)=0.065 when we consider a multi-parameter analysis. We find that this is mostly due to the different response of separate triangle types (e.g. equilateral and squeezed) to changes in model parameters. While weak, this shape dependence is clearly non-negligible for cosmological parameters, and it is even stronger, as expected, for intra-cluster medium parameters

    A Referral Center Experience with Cerebral Protection Devices: Challenging Cardiac Thrombus in the EP Lab

    No full text
    BACKGROUND: Cerebral protection devices (CPD) are designed to prevent cardioembolic stroke and most evidence that exists relates to TAVR procedures. There are missing data on the benefits of CPD in patients that are considered high risk for stroke undergoing cardiac procedures like left atrial appendage (LAA) closure or catheter ablation of ventricular tachycardia (VT) when cardiac thrombus is present. PURPOSE: This work aimed to examine the feasibility and safety of the routine use of CPD in patients with cardiac thrombus undergoing interventions in the electrophysiology (EP) lab of a large referral center. METHODS: The CPD was placed under fluoroscopic guidance in all procedures in the beginning of the intervention. Two different CPDs were used according to the physician’s discretion: (1) a capture device consisting of two filters for the brachiocephalic and left common carotid arteries placed over a 6F sheath from a radial artery; or (2) a deflection device covering all three supra-aortic vessels placed over an 8F femoral sheath. Retrospective periprocedural and safety data were obtained from procedural reports and discharge letters. Long-term safety data were obtained by clinical follow-up in our institution and telephone consultations. RESULTS: We identified 30 consecutive patients in our EP lab who underwent interventions (21 LAA closure, 9 VT ablation) with placement of a CPD due to cardiac thrombus. Mean age was 70 ± 10 years and 73% were male, while mean LVEF was 40 ± 14%. The location of the cardiac thrombus was the LAA in all 21 patients (100%) undergoing LAA-closure, whereas, in the 9 patients undergoing VT ablation, thrombus was present in the LAA in 5 cases (56%), left ventricle (n = 3, 33%) and aortic arch (n = 1, 11%). The capture device was used in 19 out of 30 (63%) and the deflection device in 11 out of 30 cases (37%). There were no periprocedural strokes or transitory ischemic attacks (TIA). CPD-related complications comprised the vascular access and were as follows: two cases of pseudoaneurysm of the femoral artery not requiring surgery (7%), 1 hematoma at the arterial puncture site (3%) and 1 venous thrombosis (3%) resolved by warfarin. At long-term follow-up, 1 TIA and 2 non-cardiovascular deaths occurred, with a mean follow-up time of 660 days. CONCLUSIONS: Placement of a cerebral protection device prior to LAA closure or VT ablation in patients with cardiac thrombus proved feasible, but possible vascular complications needed to be taken into account. A benefit in periprocedural stroke prevention for these interventions seemed plausible but has yet to be proven in larger and randomized trials
    corecore