9 research outputs found

    PRRSV RNA detection in different matrices under typical storage conditions in the UK

    Get PDF
    In the UK, approximately 40 per cent of the pig breeding herds are outdoors. To monitor their porcine reproductive and respiratory syndrome virus (PRRSV) status, blood is collected commonly from piglets around weaning. Sample collection in British outdoor pigs often occurs during the early morning hours when the piglets tend to accumulate inside sheltered areas. For practical reasons, dry cotton swabs are occasionally used for blood collection and stored at room temperature until arrival in the laboratory. Detection of PRRSV RNA is a function of viral concentration, sample type and storage condition. To evaluate a possible impact of the sampling protocol on PRRSV1 detection, experimentally spiked blood samples using three dilutions of a representative PRRSV1 strain were prepared. In addition, blood samples from pigs naturally infected with PRRSV were obtained from a PRRSV-positive British herd. Spiked blood and blood from infected pigs were used to obtain sera, dry or wet (immersed in saline) polyester or cotton swabs and FTA cards. The different samples were stored for 24 hours, 48 hours or 7 days at 4°C or 20°C and tested by a real-time reverse transcriptase PRRSV PCR assay. Under the study conditions, the best matrix was serum (96.7 per cent), followed by wet swabs (78 per cent), dry swabs (61.3 per cent) and FTA cards (51 per cent). Polyester swabs (76 per cent) showed a better performance than cotton swabs (63.3 per cent). The reduction in sensitivity obtained for swabs and FTA cards was particularly high at low viral concentrations. The results indicate that wet polyester swabs should be used whenever possible

    Bacillus pumilus probiotic feed supplementation mitigates Lawsonia intracellularis shedding and lesions

    Get PDF
    International audienceAbstractThe causative agent of ileitis, Lawsonia intracellularis, is commonly associated with diarrhea and reduced weight gain in growing pigs. The effect of in-feed probiotics on L. intracellularis infection dynamics was evaluated. In brief, 70 2.5-week-old-pigs were randomly divided into six groups with 10–20 pigs each. All pigs were fed an age appropriate base ration for the duration of the study, which was supplemented with one of three Bacillus strains including B. amyloliquefaciens (T01), B. licheniformis (T02) and B. pumilus (T03). Another group was orally vaccinated with a commercial live L. intracellularis vaccine (VAC) at 3 weeks of age. At 7 weeks of age, T01-LAW, T02-LAW, T03-LAW, VAC-LAW and the POS-CONTROL groups were challenged with L. intracellularis while the NEG-CONTROL pigs were not challenged. All pigs were necropsied 16 days later. By the time of inoculation, all VAC-LAW pigs had seroconverted and at necropsy 10–65% of the pigs in all other challenged groups were also seropositive. The results indicate a successful L. intracellularis challenge with highest bacterial DNA levels in POS-CONTROL pigs, VAC-LAW pigs and T01-LAW pigs. There was a delay in onset of shedding in T02-LAW and T03-LAW groups, which was reflected in less severe macroscopic and microscopic lesions, reduced intralesional L. intracellularis antigen levels and a lower area under the curve for bacterial shedding. Under the study conditions, two of the probiotics tested suppressed L. intracellularis infection. The obtained findings show the potential of probiotics in achieving antibiotic-free control of L. intracellularis

    Saliva Alternative to Upper Respiratory Swabs for SARS-CoV-2 Diagnosis

    Get PDF
    PCR of upper respiratory specimens is the diagnostic standard for severe acute respiratory syndrome coronavirus 2 infection. However, saliva sampling is an easy alternative to nasal and throat swabbing. We found similar viral loads in saliva samples and in nasal and throat swab samples from 110 patients with coronavirus disease

    Evaluation of eight lateral flow tests for the detection of anti-SARS-CoV-2 antibodies in a vaccinated population

    Get PDF
    Background: Rapid determination of an individual's antibody status can be beneficial in understanding an individual's immune response to SARS-CoV-2 and for initiation of therapies that are only deemed effective in sero-negative individuals. Antibody lateral flow tests (LFTs) have potential to address this need as a rapid, point of care test. Methods: Here we present a proof-of-concept evaluation of eight LFT brands using sera from 95 vaccinated individuals to determine sensitivity for detecting vaccination generated antibodies. Samples were analysed on eight different brands of antibody LFT and an automated chemiluminescent microparticle immunoassay (CMIA) that identifies anti-spike antibodies which was used as our reference standard. Results: All 95 (100%) participants tested positive for anti-spike antibodies by the chemiluminescent microparticle immunoassay (CMIA) reference standard post-dose two of their SARS-CoV-2 vaccine: BNT162b2 (Pfizer/BioNTech, n = 60), AZD1222 (AstraZeneca, n = 31), mRNA-1273 (Moderna, n = 2) and Undeclared Vaccine Brand (n = 2). Sensitivity increased from dose one to dose two in six out of eight LFTs with three tests achieving 100% sensitivity at dose two in detecting anti-spike antibodies. Conclusions: These tests are demonstrated to be highly sensitive to detect raised antibody levels in vaccinated individuals. RDTs are low cost and rapid alternatives to ELISA based systems

    Use of the rSpaA415 antigen indicates low rates of Erysipelothrix rhusiopathiae infection in farmed cattle from the United States of America and Great Britain

    Get PDF
    Background Clinical cases of Erysipelothrix rhusiopathiae, a zoonotic gram-positive bacterium, have been reported in many ruminant species, including in cattle, deer, moose and muskoxen. Fatal cases have been repeatedly reported in cattle over the years but to date there is only one Japanese study investigating the seroprevalence of this bacterium in cattle using the growth agglutination test (GAT). This technique is subjective, time-consuming, expensive and hazardous compared to modern serological tests such as enzyme-linked immunosorbent assays (ELISA) or the newly developed fluorescent microbead-based immunoassays (FMIA). Results The FMIA based on the surface protein SpaA (rSpaA415) antigen of E. rhusiopathiae developed in this study had an almost perfect agreement with the GAT (k = 0.83) and showed a sensitivity of 89.7% and a specificity of 92.9% when compared to the GAT. Overall, detection rates of E. rhusiopathiae antibody positive samples were 13.8% (51/370) in British herds and 6% (12/200) in US herds. Positive cattle were present in 34.3% (24/70) of the investigated British farms and in 34.7% (8/23) of the US farms with an on-farm prevalence of 7.1 to 100% for the British farms and 8.3–30% for the US farms. Conclusions FMIA is a fast, safe and economic alternative to the GAT for the diagnosis of E. rhusiopathiae in cattle. This work is the first seroprevalence study of E. rhusiopathiae in healthy farmed cattle in Great Britain and the US and revealed that infection occurs at a low level. Further investigations to evaluate risks of zoonotic transmission when handling cattle are needed

    Molecular surveillance reveals widespread colonisation by carbapenemase and extended spectrum beta-lactamase producing organisms in neonatal units in Kenya and Nigeria

    Get PDF
    Objectives: Neonatal sepsis, a major cause of death amongst infants in sub-Saharan Africa, is often gut derived. Gut colonisation by Enterobacteriaceae producing extended spectrum beta-lactamase (ESBL) or carbapenemase enzymes can lead to antimicrobial-resistant (AMR) or untreatable infections. We sought to explore the rates of colonisation by ESBL or carbapenemase producers in two neonatal units (NNUs) in West and East Africa. Methods: Stool and rectal swab samples were taken at multiple timepoints from newborns admitted to the NNUs at the University College Hospital, Ibadan, Nigeria and the Jaramogi Oginga Odinga Teaching and Referral Hospital, Kisumu, western Kenya. Samples were tested for ESBL and carbapenemase genes using a previously validated qPCR assay. Kaplan-Meier survival analysis was used to examine colonisation rates at both sites. Results: In total 119 stool and rectal swab samples were taken from 42 infants admitted to the two NNUs. Colonisation with ESBL (37 infants, 89%) was more common than with carbapenemase producers (26, 62.4%; P = 0.093). Median survival time before colonisation with ESBL organisms was 7 days and with carbapenemase producers 16 days (P = 0.035). The majority of ESBL genes detected belonged to the CTX-M-1 (36/38; 95%), and CTX-M-9 (2/36; 5%) groups, and the most prevalent carbapenemase was blaNDM (27/29, 93%). Conclusions: Gut colonisation of neonates by AMR organisms was common and occurred rapidly in NNUs in Kenya and Nigeria. Active surveillance of colonisation will improve the understanding of AMR in these settings and guide infection control and antibiotic prescribing practice to improve clinical outcomes

    A prospective diagnostic evaluation of accuracy of self-taken and healthcare worker-taken swabs for rapid COVID-19 testing

    Get PDF
    Background Rapid diagnostic tests (RDTs) developed for point of care detection of SARS-CoV-2 antigen are recommended by WHO to use trained health care workers to collect samples. We hypothesised that self-taken samples are non-inferior for use with RDTs to diagnose COVID-19. We designed a prospective diagnostic evaluation comparing self-taken and healthcare worker (HCW)-taken throat/nasal swabs to perform RDTs for SARS-CoV-2, and how these compare to RT-PCR. Methods Eligible participants 18 years or older with symptoms of COVID-19. 250 participants recruited at the NHS Test and Trace drive-through community PCR testing site (Liverpool, UK); one withdrew before analysis. Self-administered throat/nasal swab for the Covios® RDT, a trained HCW taken throat/nasal sample for PCR and HCW comparison throat/nasal swab for RDT were collected. RDT results were compared to RT-PCR, as the reference standard, to calculate sensitivity and specificity. Findings Seventy-five participants (75/249, 30.1%) were positive by RT-PCR. RDTs with self-taken swabs had a sensitivity of 90.5% (67/74, 95% CI: 83.9–97.2), compared to 78.4% (58/74, 95% CI: 69.0–87.8) for HCW-taken swabs (absolute difference 12.2%, 95% CI: 4.7–19.6, p = 0.003). Specificity for self-taken swabs was 99.4% (173/174, 95% CI: 98.3–100.0), versus 98.9% (172/174, 95% CI: 97.3–100.0) for HCW-taken swabs (absolute difference 0.6%, 95% CI: 0.5–1.7, p = 0.317). The PPV of self-taken RDTs (98.5%, 67/68, 95% CI: 95.7–100.0) and HCW-taken RDTs (96.7%, 58/60, 95% CI 92.1–100.0) were not significantly different (p = 0.262). However, the NPV of self-taken swab RDTs was significantly higher (96.1%, 173/180, 95% CI: 93.2–98.9) than HCW-taken RDTs (91.5%, 172/188, 95% CI 87.5–95.5, p = 0.003). Interpretation In conclusion, self-taken swabs for COVID-19 testing offer an accurate alternative to healthcare worker taken swabs for use with RDTs. Our results demonstrate that, with no training, self-taken throat/nasal samples can be used by lay individuals as part of rapid testing programmes for symptomatic adults. This is especially important where the lack of trained healthcare workers restricts access to testing

    Evaluation of eight lateral flow tests for the detection of anti-SARS-CoV-2 antibodies in a vaccinated population

    Get PDF
    Background: Rapid determination of an individual’s antibody status can be beneficial in understanding an individual’s immune response to SARS-CoV-2 and for initiation of therapies that are only deemed effective in sero-negative individuals. Antibody lateral flow tests (LFTs) have potential to address this need as a rapid, point of care test. Methods: Here we present a proof-of-concept evaluation of eight LFT brands using sera from 95 vaccinated individuals to determine sensitivity for detecting vaccination generated antibodies. Samples were analysed on eight different brands of antibody LFT and an automated chemiluminescent microparticle immunoassay (CMIA) that identifies anti-spike antibodies which was used as our reference standard. Results: All 95 (100%) participants tested positive for anti-spike antibodies by the chemiluminescent microparticle immunoassay (CMIA) reference standard post-dose two of their SARS-CoV-2 vaccine: BNT162b2 (Pfizer/BioNTech, n = 60), AZD1222 (AstraZeneca, n = 31), mRNA-1273 (Moderna, n = 2) and Undeclared Vaccine Brand (n = 2). Sensitivity increased from dose one to dose two in six out of eight LFTs with three tests achieving 100% sensitivity at dose two in detecting anti-spike antibodies. Conclusions: These tests are demonstrated to be highly sensitive to detect raised antibody levels in vaccinated individuals. RDTs are low cost and rapid alternatives to ELISA based systems

    IgG Seroconversion and Pathophysiology in Severe Acute Respiratory Syndrome Coronavirus 2 Infection

    No full text
    We investigated the dynamics of seroconversion in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. During March 29–May 22, 2020, we collected serum samples and associated clinical data from 177 persons in London, UK, who had SARS-CoV-2 infection. We measured IgG against SARS-CoV-2 and compared antibody levels with patient outcomes, demographic information, and laboratory characteristics. We found that 2.0%–8.5% of persons did not seroconvert 3–6 weeks after infection. Persons who seroconverted were older, were more likely to have concurrent conditions, and had higher levels of inflammatory markers. Non-White persons had higher antibody concentrations than those who identified as White; these concentrations did not decline during follow-up. Serologic assay results correlated with disease outcome, race, and other risk factors for severe SARS-CoV-2 infection. Serologic assays can be used in surveillance to clarify the duration and protective nature of humoral responses to SARS-CoV-2 infection
    corecore