75 research outputs found

    Efficacy and patient satisfaction with autoadjusting CPAP with variable expiratory pressure vs standard CPAP: a two-night randomized crossover trial

    Get PDF
    Expiratory pressure relief (C-Flex) technology monitors the patient’s airflow during expiration and reduces the pressure in response to the patient. Increased comfort levels associated with C-Flex therapy have potential to improve patient adherence to therapy. The purpose of this study was to assess the combination of autoadjusting CPAP (APAP) and C-Flex in terms of (1) treatment efficacy, and (2) patient preference when compared to standard CPAP. Fifteen patients who had previously undergone formal CPAP titration polysomnography were treated with either one night of the APAP with C-Flex or one night of conventional CPAP, in a crossover trial. Patient satisfaction levels were recorded using visual analog scales (VAS) on the morning after the study. Mean patient age was 50 ± 12 years, body mass index (BMI) was 36 ± 6 kg/m(2), baseline AHI was 53 ± 31 events/h, and CPAP Pressure was 11 ± 2 cm/H(2)O. APAP with C-Flex was as effective as CPAP, with no differences detected in sleep latency (17 ± 5 vs 12.3 ± 3 min, p = 0.4), or respiratory indices (AHI of 4.2 ± 2 vs 2.4 ± 0.7 events/h, p = 0.1). VAS scores (scale 0–10) indicated a trend towards increased patient satisfaction while using APAP with C-Flex (7.9 vs 7.2, p = 0.07). 10 patients expressed a preference for APAP with C-Flex (VAS, 0 to10) over standard CPAP (total positive score of 68, mean score of 4.8 ± 4.3). One patient expressed no preference. Four patients expressed a preference for CPAP (total positive score of 13, mean score of 0.9 ± 1.9) (APAP with C-Flex vs standard CPAP, p < 0.01 paired t test). APAP with C-Flex eliminates sleep disordered breathing as effectively as standard CPAP. Patients indicated a preference for APAP with C-Flex suggesting a possible advantage in terms of patient adherence for this mode of treatment

    Randomised short-term trial of high-span versus low-span APAP for treating sleep apnoea

    Get PDF
    PURPOSE: Auto-titrating continuous positive airway pressure (APAP) devices were developed to improve treatment efficacy and compliance in patients with obstructive sleep apnoea syndrome (OSAS). Since there are insufficient data on the optimal pressure range setting, we aimed to compare the adherence, efficacy and tolerability of treatment with high-span versus low-span APAP. METHODS: Seventy-six newly diagnosed OSAS patients fulfilling the treatment criteria were randomised to receive high-span (HS, range 4-15cmH2O, n?=?38) or low-span (LS, range 8-12cmH2O, n?=?38) APAP. Patients were assessed at 1 and 3 months. RESULTS: Median Epworth sleepiness scale (ESS) was 13 (IQR, 6-16) and median apnoea-hypopnoea index (AHI) was 35.9 (IQR, 27.6-56.3). There were no significant differences in baseline demographic and clinical characteristics between groups. Overall, no significant differences were found at the first month assessment. After 3 months of therapy, we found again no differences in residual AHI or ESS. However, the group HS proved less adherent than group LS, respectively, with median 87 % (IQR, 60.5-97.5) versus 94 % (IQR, 80.0-98.3) of the nights using =4 h (P?=?0.014) and mean (±SD) usage 5.7?±?1.6 versus 6.4?±?1.2 h/night (P?=?0.049). The group HS reported more frequently nasal congestion, excessive oronasal dryness and nocturnal awakenings of at least moderate intensity, the latter with statistical significance (P?=?0.005). CONCLUSIONS: Both pressure ranges appear to be equally effective to correct AHI and to improve symptoms. Though, patients with high-span APAP were less compliant to treatment, raising issues about the tolerability of wide pressure range settings of these devices.T Pinto has received financial support from Linde and Vitalaire (Healthcare Providers) for attending symposia and honoraria for speaking at symposia from Philips. After the conclusion of the study, JC Winck has started working in a global position for Linde. The remaining authors declare that they have no conflict of interest

    Cheyne-Stokes respiration in patients hospitalised for heart failure

    Get PDF
    BACKGROUND: Previous studies showing a strong relationship between Cheyne-Stokes respiration and the severity of left ventricular systolic dysfunction have usually been done in selected patient populations with lower age and a higher proportion of males than the "typical" in-hospital patient with heart failure. The purpose of the present study was test the strength of this relationship in unselected patients admitted to hospital due to decompensated chronic heart failure. METHODS: We evaluated 191 patients (32% women), mean age 73 years, ready for discharge from the heart failure unit in the University Hospital of Malmö, Sweden. The patients underwent echocardiography for determination of left ventricular ejection fraction and left ventricular inner diastolic diameter. A respiratory investigation during sleep was performed the last night before discharge. RESULTS: We found that 66% of the patients had Cheyne-Stokes respiration more than 10% of the total recording time. Only 7 (3.6%) of the patients had predominantly obstructive apnoeas. There was a significant but very weak relationship between left ventricular ejection fraction and left ventricular inner diastolic diameter on one hand and Cheyne-Stokes respiration on the other. Age was a stronger determinant of Cheyne-Stokes respiration than any of the cardiac or other clinical variables. CONCLUSION: Although presence of Cheyne-Stokes respiration indicates left ventricular dysfunction, its severity seems only weakly related to the severity of heart failure. Age was found to be a stronger determinant, which may reflect the underlying age-dependency found also in healthy subjects. Due to age restrictions or other selection criteria, the importance of age may have been underestimated in many previous studies on factors associated with Cheyne-Stokes respiration

    Switch of noninvasive ventilation (NIV) to continuous positive airway pressure (CPAP) in patients with obesity hypoventilation syndrome: a pilot study

    Get PDF
    International audienceObesity is a major worldwide public health issue. The main respiratory complication stemming from obesity is obesity hypoventilation syndrome (OHS). Most of the OHS patients diagnosed during an exacerbation are treated with non invasive ventilation (NIV). Up to date, no prospective study has demonstrated in real life conditions the feasibility of a systematic protocoled switch of NIV to continuous positive airway pressure (CPAP), once stability is achieved

    Tension-type headache and sleep apnea in the general population

    Get PDF
    The main objective of this study is to investigate the relationship between tension-type headache and obstructive sleep apnea in the general population. The method involves a cross-sectional population-based study. A random age and gender stratified sample of 40,000 persons aged 20–80 years residing in Akershus, Hedmark or Oppland County, Norway were drawn by the National Population Register. A postal questionnaire containing the Berlin Questionnaire was used to classify respondents to be of either high or low risk of obstructive sleep apnea. Included in this study were 297 persons with high risk and 134 persons with low risk of sleep apnea, aged 30–65 years. They underwent an extensive clinical interview, a physical and a neurological examination by physicians, and in-hospital polysomnography. Those with apnea hypopnoea index (AHI) ≥5 were classified with obstructive sleep apnea. Tension-type headache was diagnosed according to the International Classification of Headache Disorders. Results showed the prevalence of frequent and chronic tension-type headache was 18.7 and 2.1% in the participants with obstructive sleep apnea. The logistic regression analyses showed no significant relationship between tension-type headache and obstructive sleep apnea, with adjusted odds ratios for frequent tension-type headache of 0.95 (0.55–1.62) and chronic tension-type headache of 1.91 (0.37–9.85). The results did not change when using cut-off of moderate (AHI ≥15) and severe (AHI ≥30) obstructive sleep apnea. Thus, we did not find any significant relationship between tension-type headache and the AHI. The presence and severity of sleep apneas seem not to influence presence and attack-frequency of tension-type headache in the general population

    Obesity and craniofacial variables in subjects with obstructive sleep apnea syndrome: comparisons of cephalometric values

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of this paper was to determine the most common craniofacial changes in patients suffering Obstructive Sleep Apnea Syndrome (OSAS) with regards to the degree of obesity. Accordingly, cephalometric data reported in the literature was searched and analyzed.</p> <p>Methods</p> <p>After a careful analysis of the literature from 1990 to 2006, 5 papers with similar procedural criteria were selected. Inclusion criteria were: recruitment of Caucasian patients with an apnea-hypopnea index (AHI) >10 as grouped in non-obese (Body Mass Index – [BMI] < 30) <it>vs</it>. obese (BMI ≥ 30).</p> <p>Results</p> <p>A low position of the hyoid bone was present in both groups. In non-obese patients, an increased value of the ANB angle and a reduced dimension of the cranial base (S-N) were found to be the most common finding, whereas major skeletal divergence (ANS-PNS ^Go-Me) was evident among obese patients. No strict association was found between OSAS and length of the soft palate.</p> <p>Conclusion</p> <p>In both non-obese and obese OSAS patients, skeletal changes were often evident; with special emphasis of intermaxillary divergence in obese patients. Unexpectedly, in obese OSAS patients, alterations of oropharyngeal soft tissue were not always present and did not prevail.</p
    corecore