    A Discrete Event Simulation model to evaluate the treatment pathways of patients with Cataract in the United Kingdom

    Get PDF
    Background The number of people affected by cataract in the United Kingdom (UK) is growing rapidly due to ageing population. As the only way to treat cataract is through surgery, there is a high demand for this type of surgery and figures indicate that it is the most performed type of surgery in the UK. The National Health Service (NHS), which provides free of charge care in the UK, is under huge financial pressure due to budget austerity in the last decade. As the number of people affected by the disease is expected to grow significantly in coming years, the aim of this study is to evaluate whether the introduction of new processes and medical technologies will enable cataract services to cope with the demand within the NHS funding constraints. Methods We developed a Discrete Event Simulation model representing the cataract services pathways at Leicester Royal Infirmary Hospital. The model was inputted with data from national and local sources as well as from a surgery demand forecasting model developed in the study. The model was verified and validated with the participation of the cataract services clinical and management teams. Results Four scenarios involving increased number of surgeries per half-day surgery theatre slot were simulated. Results indicate that the total number of surgeries per year could be increased by 40% at no extra cost. However, the rate of improvement decreases for increased number of surgeries per half-day surgery theatre slot due to a higher number of cancelled surgeries. Productivity is expected to improve as the total number of doctors and nurses hours will increase by 5 and 12% respectively. However, non-human resources such as pre-surgery rooms and post-surgery recovery chairs are under-utilized across all scenarios. Conclusions Using new processes and medical technologies for cataract surgery is a promising way to deal with the expected higher demand especially as this could be achieved with limited impact on costs. Non-human resources capacity need to be evenly levelled across the surgery pathway to improve their utilisation. The performance of cataract services could be improved by better communication with and proactive management of patients.Peer reviewedFinal Published versio

    Effectiveness of screening preschool children for amblyopia: a systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Amblyopia and amblyogenic factors like strabismus and refractive errors are the most common vision disorders in children. Although different studies suggest that preschool vision screening is associated with a reduced prevalence rate of amblyopia, the value of these programmes is the subject of a continuing scientific and health policy discussion. Therefore, this systematic review focuses on the question of whether screening for amblyopia in children up to the age of six years leads to better vision outcomes.</p> <p>Methods</p> <p>Ten bibliographic databases were searched for randomised controlled trials, non-randomised controlled trials and cohort studies with no limitations to a specific year of publication and language. The searches were supplemented by handsearching the bibliographies of included studies and reviews to identify articles not captured through our main search strategy.</p> <p>Results</p> <p>Five studies met the inclusion criteria. Of these, three studies suggested that screening is associated with an absolute reduction in the prevalence of amblyopia between 0.9% and 1.6% (relative reduction: between 45% and 62%). However, the studies showed weaknesses, limiting the validity and reliability of their findings. The main limitation was that studies with significant results considered only a proportion of the originally recruited children in their analysis. On the other hand, retrospective sample size calculation indicated that the power based on the cohort size was not sufficient to detect small changes between the groups. Outcome parameters such as quality of life or adverse effects of screening have not been adequately investigated in the literature currently available.</p> <p>Conclusion</p> <p>Population based preschool vision screening programmes cannot be sufficiently assessed by the literature currently available. However, it is most likely that the present systematic review contains the most detailed description of the main limitations in current available literature evaluating these programmes. Therefore, future research work should be guided by the findings of this publication.</p

    Pain and stress assessment after retinopathy of prematurity screening examination: Indirect ophthalmoscopy versus digital retinal imaging

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Increasingly, neonatal clinics seek to minimize painful experiences and stress for premature infants. Fundoscopy performed with a binocular indirect ophthalmoscope is the reference examination technique for screening of retinopathy of prematurity (ROP), and it is associated with pain and stress. Wide-field digital retinal imaging is a recent technique that should be evaluated for minimizing infant pain and stress.</p> <p>Methods</p> <p>The purpose of the study was to assess and compare the impact of using a binocular indirect ophthalmoscope (BIO), or wide-field digital retinal imaging (WFDRI) on pain and stress in infants undergoing ROP screening examination. This was a comparative evaluation study of two screening procedures. Ophthalmologic examinations (N = 70) were performed on 24 infants with both BIO and WFDRI. Pain assessments were performed with two specific neonatal scales (Crying, requires oxygen, increased vital signs, expression and sleeplessness, CRIES and, Premature infant pain profile, PIPP) just prior to the examination, and 30 seconds, 1 hour, and 24 hours later after ending the examination.</p> <p>Results</p> <p>Changes over time were significantly different between BIO and WFDRI with both scales (PIPP score, <it>p</it> = .007, and CRIES score, <it>p</it> = .001). Median PIPP score (interquartile interval) at baseline was 4 (3–5). At 30 seconds the score was 8 (6–9) for BIO and 6 (5–7) for WFDRI, respectively. The increase in PIPP score between baseline and 30 seconds was significantly lower with WFDRI (<it>p</it> = .006). The median increase in CRIES score from baseline to 30 seconds was 1 point lower for WFDRI than for BIO (<it>p</it> < .001). No significant difference in response remained at 1 hour or 24 hour assessments.</p> <p>Conclusions</p> <p>A transient short-term pain and stress response occurs with both BIO and WFDRI. Infants examined for screening of ROP with digital retinal imaging present less pain and stress at 30 seconds following completion of the exam when compared with binocular indirect ophthalmoscopy.</p
    corecore