32 research outputs found

    High prevalence of new clinically significant findings in patients with embolic stroke of unknown source evaluated by cardiac magnetic resonance imaging

    Get PDF
    Background: Embolic stroke of unknown source (ESUS) accounts for one in six ischaemic strokes. Current guidelines do not recommend routine cardiac magnetic resonance (CMR) imaging in ESUS and, beyond the identification of cardio-embolic sources, there are no data assessing new clinical findings from CMR in ESUS. This study aimed to assess the prevalence of new cardiac and non-cardiac findings and to determine their impact on clinical care in patients with ESUS.Methods and Results: In this prospective, multicentre, observational study, CMR was performed within 3-months of ESUS. All scans were reported according to standard clinical practice. A new clinical finding was defined as one not previously identified through prior clinical evaluation. A clinically significant finding was defined as one resulting in further investigation, follow-up or treatment. A change in patient care was defined as initiation of medical, interventional, surgical or palliative care. From 102 patients recruited, 96 underwent CMR. One or more new clinical findings were observed in 59 patients (61%). New findings were clinically significant in 48 (81%) of these patients. Of 40 patients with a new clinically significant cardiac finding, 21 (53%) experienced a change in care (medical therapy, n=15; interventional/surgical procedure, n=6). In 12 patients with a new clinically significant extra-cardiac finding, 6 (50%) experienced a change in care (medical therapy, n=4; palliative care, n=2). Conclusions: CMR imaging identifies new clinically significant cardiac and non-cardiac findings in half of patients with recent ESUS. Advanced cardiovascular screening should be considered in patients with ESUS.<br/

    Viability and Outcomes With Revascularization or Medical Therapy in Ischemic Ventricular Dysfunction: A Prespecified Secondary Analysis of the REVIVED-BCIS2 Trial.

    Get PDF
    IMPORTANCE: In the Revascularization for Ischemic Ventricular Dysfunction (REVIVED-BCIS2) trial, percutaneous coronary intervention (PCI) did not improve outcomes for patients with ischemic left ventricular dysfunction. Whether myocardial viability testing had prognostic utility for these patients or identified a subpopulation who may benefit from PCI remained unclear. OBJECTIVE: To determine the effect of the extent of viable and nonviable myocardium on the effectiveness of PCI, prognosis, and improvement in left ventricular function. DESIGN, SETTING, AND PARTICIPANTS: Prospective open-label randomized clinical trial recruiting between August 28, 2013, and March 19, 2020, with a median follow-up of 3.4 years (IQR, 2.3-5.0 years). A total of 40 secondary and tertiary care centers in the United Kingdom were included. Of 700 randomly assigned patients, 610 with left ventricular ejection fraction less than or equal to 35%, extensive coronary artery disease, and evidence of viability in at least 4 myocardial segments that were dysfunctional at rest and who underwent blinded core laboratory viability characterization were included. Data analysis was conducted from March 31, 2022, to May 1, 2023. INTERVENTION: Percutaneous coronary intervention in addition to optimal medical therapy. MAIN OUTCOMES AND MEASURES: Blinded core laboratory analysis was performed of cardiac magnetic resonance imaging scans and dobutamine stress echocardiograms to quantify the extent of viable and nonviable myocardium, expressed as an absolute percentage of left ventricular mass. The primary outcome of this subgroup analysis was the composite of all-cause death or hospitalization for heart failure. Secondary outcomes were all-cause death, cardiovascular death, hospitalization for heart failure, and improved left ventricular function at 6 months. RESULTS: The mean (SD) age of the participants was 69.3 (9.0) years. In the PCI group, 258 (87%) were male, and in the optimal medical therapy group, 277 (88%) were male. The primary outcome occurred in 107 of 295 participants assigned to PCI and 114 of 315 participants assigned to optimal medical therapy alone. There was no interaction between the extent of viable or nonviable myocardium and the effect of PCI on the primary or any secondary outcome. Across the study population, the extent of viable myocardium was not associated with the primary outcome (hazard ratio per 10% increase, 0.98; 95% CI, 0.93-1.04) or any secondary outcome. The extent of nonviable myocardium was associated with the primary outcome (hazard ratio, 1.07; 95% CI, 1.00-1.15), all-cause death, cardiovascular death, and improvement in left ventricular function. CONCLUSIONS AND RELEVANCE: This study found that viability testing does not identify patients with ischemic cardiomyopathy who benefit from PCI. The extent of nonviable myocardium, but not the extent of viable myocardium, is associated with event-free survival and likelihood of improvement of left ventricular function. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01920048

    Appendectomy during the COVID-19 pandemic in Italy: a multicenter ambispective cohort study by the Italian Society of Endoscopic Surgery and new technologies (the CRAC study)

    Get PDF
    Major surgical societies advised using non-operative management of appendicitis and suggested against laparoscopy during the COVID-19 pandemic. The hypothesis is that a significant reduction in the number of emergent appendectomies was observed during the pandemic, restricted to complex cases. The study aimed to analyse emergent surgical appendectomies during pandemic on a national basis and compare it to the same period of the previous year. This is a multicentre, retrospective, observational study investigating the outcomes of patients undergoing emergent appendectomy in March-April 2019 vs March-April 2020. The primary outcome was the number of appendectomies performed, classified according to the American Association for the Surgery of Trauma (AAST) score. Secondary outcomes were the type of surgical technique employed (laparoscopic vs open) and the complication rates. One thousand five hundred forty one patients with acute appendicitis underwent surgery during the two study periods. 1337 (86.8%) patients met the inclusion criteria: 546 (40.8%) patients underwent surgery for acute appendicitis in 2020 and 791 (59.2%) in 2019. According to AAST, patients with complicated appendicitis operated in 2019 were 30.3% vs 39.9% in 2020 (p = 0.001). We observed an increase in the number of post-operative complications in 2020 (15.9%) compared to 2019 (9.6%) (p &lt; 0.001). The following determinants increased the likelihood of complication occurrence: undergoing surgery during 2020 (+ 67%), the increase of a unit in the AAST score (+ 26%), surgery performed &gt; 24 h after admission (+ 58%), open surgery (+ 112%) and conversion to open surgery (+ 166%). In Italian hospitals, in March and April 2020, the number of appendectomies has drastically dropped. During the first pandemic wave, patients undergoing surgery were more frequently affected by more severe appendicitis than the previous year's timeframe and experienced a higher number of complications. Trial registration number and date: Research Registry ID 5789, May 7th, 202

    Composite Ni-TiO2 nanotube arrays electrode for photo-assisted electrolysis

    No full text
    This article is addressed to define a new composite electrode constituted by porous nickel and an array of highly ordered TiO2nanotubes obtained by a previous galvanostatic anodization treatment in an ethylene glycol solution. The electrochemical performances of the composite anode were evaluated in a photo-electrolyser, which showed good solar conversion efficiency with respect to the UV irradiance together with a reduction of energy consumption. Such a combination of materials makes our system simple and able to work both in dark and under solar light exposure, thus opening new perspectives for industrial-scale applications

    Nickel-TiO2 nanotube anode for photo-electrolysers

    No full text
    This work evaluated a new combined electrode constituted by porous nickel and an array of highly ordered TiO2 nanotubes achieved by a former galvanostatic anodization treatment in an ethylene glycol solution. The photo-electrochemical response of the composite anode was appraised. It showed a mixed behaviour with interesting features with respect to its single components. Based on the characterization of the single electrode, a composite multi-anode has been realized and tested with direct sunlight exposition in a small photo-electrolyser. The system showed good solar conversion efficiency together with a reduction in energy consumption. The results highlighted that a photo-electrolyser, operating with a cell voltage of 2 V and with a correct insulation, guaranteed by an appropriate design and an optimal management of the gas products, could reduce by at least 3.5% its energy demand. Such a combination of materials makes the new system able to work both in dark and under solar light exposure, thus opening new perspectives for industrial-scale applications

    On‐Chip Thermoelectric Devices Based on Standard Silicon Processing

    No full text
    : The strong reduction of thermal conductivity with respect to bulk silicon makes nanostructured silicon one of the best materials for highly efficient direct conversion of heat into electrical power and vice-versa. The widespread technologies for the integration of silicon devices can be used to define on-chip micro thermoelectric generators (scavengers); similar structures could also be used for precise and well-localized cooling through the reverse process of heat pumping. However, the road to the fabrication of integrated thermal energy scavengers or cooler, based on silicon, is still very long. In this work, the design and the fabrication process of on-chip thermoelectric devices based on a large number of interconnected monocrystalline silicon nanobeams, very tall (&gt;1 μm) and thin (less than 200 nanometers), arranged in large areas combs is shown. The small width of the nanobeams gives a reduced thermal conductivity, and the height perpendicular to the substrate allows the definition of a highly dense collection of nanostructures. The total cross-section&nbsp;is far broader than that of other nanostructures, a characteristic that guarantees both mechanical stability and larger deliverable power per unit area

    Fast cardiac T 1ρ,adiab mapping using slice-selective adiabatic spin-lock preparation pulses.

    No full text
    PurposeMyocardial T1ρ mapping techniques commonly acquire multiple images in one breathhold to calculate a single-slice T1ρ map. Recently, non-selective adiabatic pulses have been used for robust spin-lock preparation (T1ρ,adiab). The objective of this study was to develop a fast multi-slice myocardial T1ρ,adiab mapping approach.MethodsThe proposed-sequence reduces the number of breathholds required for whole-heart 2D T1ρ,adiab mapping by acquiring multiple interleaved slices in each breathhold using slice-selective T1ρ,adiab preparation pulses. The proposed-sequence was implemented with two interleaved slices per breathhold scan and was quantitatively evaluated in phantom experiments and 10 healthy-volunteers against a single-slice T1ρ,adiab mapping sequence. The sequence was demonstrated in two patients with myocardial scar.ResultsThe phantom experiments showed the proposed-sequence had slice-to-slice variation of 1.62% ± 1.05% and precision of 4.51 ± 0.68 ms. The healthy volunteer cohort subject-wise mean relaxation time was lower for the proposed-sequence than the single-slice sequence (137.7 ± 5.3 ms vs. 148.4 ± 8.3 ms, p &lt; 0.001), and spatial-standard-deviation was better (18.7 ± 1.8 ms vs. 21.8 ± 3.4 ms, p &lt; 0.018). The mean within-subject, coefficient of variation was 5.93% ± 1.57% for the proposed-sequence and 6.31% ± 1.92% for the single-slice sequence (p = 0.35) and the effect of slice variation (0.81 ± 4.87 ms) was not significantly different to zero (p = 0.61). In both patient examples increased T1ρ,adiab (maximum American Heart Association-segment mean = 174 and 197 ms) was measured within the myocardial scar.ConclusionThe proposed sequence provides a twofold acceleration for myocardial T1ρ,adiab mapping using a multi-slice approach. It has no significant difference in within-subject variability, and significantly better precision, compared to a 2D T1ρ,adiab mapping sequence based on non-selective adiabatic spin-lock preparations.</p
    corecore