12,269 research outputs found

    Higher-Derivative Two-Dimensional Massive Fermion Theories

    Get PDF
    We consider the canonical quantization of a generalized two-dimensional massive fermion theory containing higher odd-order derivatives. The requirements of Lorentz invariance, hermiticity of the Hamiltonian and absence of tachyon excitations suffice to fix the mass term, which contains a derivative coupling. We show that the basic quantum excitations of a higher-derivative theory of order 2N+1 consist of a physical usual massive fermion, quantized with positive metric, plus 2N unphysical massless fermions, quantized with opposite metrics. The positive metric Hilbert subspace, which is isomorphic to the space of states of a massive free fermion theory, is selected by a subsidiary-like condition. Employing the standard bosonization scheme, the equivalent boson theory is derived. The results obtained are used as a guideline to discuss the solution of a theory including a current-current interaction.Comment: 23 pages, Late

    Late Stillbirth: a Ten Year Cohort Study

    Get PDF
    Introduction: Late fetal death is a desolating event that inspite the effort to implement new surveillance protocols in perinatal continues to defy our clinical pratice. Objective: To examine etiological factors contributing to main causes and conditions associated with fetal death in late pregnancies over a 10-year period. Methods: Retrospective cohort analysis of 208 late singleton stillbirth delived in a tertiary-perinatal referral maternity over a 10-year period. Clinical charts, laboratory data and feto-placental pathology findings were systematically reviewed. Results: The incidence of late fetal demise was 3.5 per 1000 pregnancies. No significant trend in the incidence of stillbirth was demonstrated during the study period. Stillbirth was intrapartum in 12 (5.8%) cases and 72 (35%) were term pregnancies. Fourteen percent of cases were undersurveilled pregnancies. Mean gestacional age at diagnosis was 34 weeks. The primary cause of death was fetal, it was present in 59 cases, 25% were considered small for gestational age. Stillbirths were unexplained in 24.5% of cases. Maternal medical disorders were identified in 21%. Hypertensive disorders were frequent and associated with early gestacional age (p = 0.028). Conclusion: There was no change in the incidence of late stillbirth during the 10 years under evaluation. The incidence was 3.5 ‰ which was identical to that described in developed countries. About one quarter of the stillbirths was unexplained. The most frequent maternal pathology was chronic hypertension

    Development of structural layers PVC incorporating phase change materials for thermal energy storage

    Get PDF
    The use of poly(vinyl chloride) (PVC) structural layers incorporating phase change materials (PCM) for latent heat thermal energy storage (LHTES) has become more attractive in the recent years compared to other supporting materials. In this study, PVC layers with different types of PCM were prepared using blending and compression moulding methods. Two types of synthesized PCM, one based on paraffin and calcium carbonate (PCM@CaCO3) and the other on paraffin, silica and graphene oxide (PCM@SiGO) have been developed to enhance the thermal conductivity of the PVC matrix and thus achieve a more effective charging and discharging process. PVC layers prepared using a commercial PCM (PCM@BASF) were also prepared for comparison. SEM images and DSC results reveal homogeneous distribution of the PCM in PVC layers and that most PCM particles are undamaged. The shell material (in the case of PCM@BASF) and the shape stability (in the case of synthesized PCM@CaCO3 and PCM@SiGO) prevent leakage of molten paraffin during the PVC layer production. The thermal conductivity profile of the PVC layer without PCM have a decreasing tendency with the temperature increase when determined using different measurement approaches, the transient plane heat source method (HotDisk Analyser, TPS 2500 S) and thermal flux meter method (steady-state method). However, for PVC layers with PCM the thermal conductivity profile shows a different behaviour when the mean surface temperature of the specimen is below the phase change transition temperature range (increasing tendency). During phase change transition (18–26 °C), the thermal conductivity presents two distinct tendencies. Firstly, the thermal conductivity reveals a decreasing tendency as the mean temperature of the specimen rises and afterwards an increasing tendency. Secondly, when the mean surface temperature is above the phase change transition temperature range, the thermal conductivity profile shows a decreasing tendency, independent of the PCM. The mechanical properties of PVC layers were also assessed and the results obtained revealed that the incorporation of PCM into the PVC matrix reduces the mechanical performance of the composites, however for LHETS applications not subjected to high tensile stress levels (over 1 kPa), this is not a significant drawback.publishe
    • …
    corecore