108 research outputs found

    Basic rockfall simulation with consideration of vegetation and application to protection measure

    Get PDF
    金沢大学理工研究域環境デザイン学系The estimation of risk due to rockfall is often done empirically. As a rational and effective method towards performance-based design of protection measures, a three-dimensional simulation method helps to describe the motion of rockfall on a slope and to consider the effect of vegetation probabilistically. This document details a typical simulation method and analyses the manner of rockfalls paired with interference of vegetation and other factors. As application, an actual slope is analyzed where rockfall occurred during the Noto Peninsula Earthquake. Finally, the validity and the benefits of the shown method are the basis for a hazard mapping for rockfall and the planning of measures

    Basic rockfall simulation with consideration of vegetation and application to protection measure

    Get PDF
    The estimation of risk due to rockfall is often done empirically. As a rational and effective method towards performance-based design of protection measures, a three-dimensional simulation method helps to describe the motion of rockfall on a slope and to consider the effect of vegetation probabilistically. This document details a typical simulation method and analyses the manner of rockfalls paired with interference of vegetation and other factors. As application, an actual slope is analyzed where rockfall occurred during the Noto Peninsula Earthquake. Finally, the validity and the benefits of the shown method are the basis for a hazard mapping for rockfall and the planning of measures

    Depolarization of multidomain ferroelectric materials

    Get PDF
    Depolarization in ferroelectric materials has been studied since the 1970s, albeit quasi-statically. The dynamics are described by the empirical Merz law, which gives the polarization switching time as a function of electric field, normalized to the so-called activation field. The Merz law has been used for decades; its origin as domain-wall depinning has recently been corroborated by molecular dynamics simulations. Here we experimentally investigate domain-wall depinning by measuring the dynamics of depolarization. We find that the boundary between thermodynamically stable and depolarizing regimes can be described by a single constant, Pr/ε0εferroEc. Among different multidomain ferroelectric materials the values of coercive field, Ec, dielectric constant, εferro, and remanent polarization, Pr, vary by orders of magnitude; the value for Pr/ε0εferroEc however is comparable, about 15. Using this extracted universal value, we show that the depolarization field is similar to the activation field, which corresponds to the transition from creep to domain-wall flow.Aerospace Structures & MaterialsNovel Aerospace Material

    Fishing for flaws

    No full text

    Specific binding of erythropoietin to its receptor on responsive mouse erythroleukemia cells.

    No full text

    Application of ozone disinfection to remove Enterococcus seriolicida, Pasteurella piscicida, and Vibrio anguillarum from seawater.

    No full text
    Survival of bacterial fish pathogens, including Enterococcus seriolicida, Vibrio anguillarum, and Pasteurella piscicida, in ozonated seawater was determined in a batch system. Bacterial counts of all fish pathogens decreased at more than 0.040 to 0.060 mg of total residual oxidants (TROs) per liter, whereas no decrease in viable counts was observed at less than 0.018 to 0.028 mg of TROs per liter. The 99% inactivation point was achieved at concentrations of 0.111 mg/liter for E. seriolicida, 0.063 mg/liter for P. piscicida, and 0.064 mg/liter for V. anguillarum within 1 min. Moreover, the mean 99 and 99.9% killing concentration-contact time (C.t) products were 0.123 and 0.186 mg.min/liter for E. seriolicida, 0.056 and 0.084 mg.min/liter for P. piscicida, and 0.081 and 0.123 mg.min/liter for V. anguillarum, respectively. However, the mean 99 and 99.9% C.t products for the mixed population in coastal seawater were 0.200 and 0.621 mg.min/liter. These results strongly suggest that ozone treatment at more than 1.0 mg of TROs per liter for several minutes is able to disinfect seawater for mariculture efficiently
    corecore