16 research outputs found

    Quantification of LSD in illicit samples by high performance liquid chromatography

    Get PDF
    In the present study, a method using high performance liquid chromatography to quantify LSD, in blotter papers seized in Minas Gerais, was optimized and validated. Linearity, precision, recovery, limits of detection and quantification, and selectivity were the parameters used to evaluate performance. The samples were extracted with methanol:water (1: 1) in an ultra-sound bath. The linearity between 0.05 and 20.00 μg/mL (0.5 and 200.0μg of LSD/blotter) was observed with satisfactory mean intra and inter assay precision (RSDr = 4.4% and RSD R = 6.4%, respectively) and with mean recoveries of 83.4% and 84.9% to the levels of 1.00 and 20.00 μg/mL (10 and 200μg LSD/blotter). The limits of detection and quantification were 0.01 and 0.05 μg/mL, respectively (0.1 and 0.5 μg of LSD/blotter). The samples of blotters (n =22) were analyzed and the mean value of 67.55 μg of LSD/blotter (RSD=27.5%) was found. Thus, the method used showed satisfactory analytical performance, and proved suitable as an analytical tool for LSD determination in illicit samples seized by police forces.No presente trabalho, um método utilizando cromatografia líquida de alta eficiência foi otimizado e validado para quantificar o LSD em selos apreendidos em Minas Gerais. A linearidade, precisão, recuperação, limites de detecção e quantificação e seletividade foram os parâmetros de desempenho avaliados. As amostras foram extraídas com metanol: água (1:1) em banho de ultra-som. A linearidade entre 0,05 a 20,00 mg/mL (0,5 a 200 μg LSD/blotter) foi observada com precisão média, intra e inter ensaio, satisfatória (RSDr = 4,4% e RSD R = 6,4%, respectivamente) e com recuperações médias de 83,4% e 84,9% para os níveis de LSD de 1,00 e 20,00 mg/mL (10 e 200 μg LSD/selo). Os limites de detecção e quantificação encontrados foram de 0,01 e 0,05 mg/mL, respectivamente (0,1 e 0,5 μg LSD/selo). As amostras de selos (n = 22) foram analisadas e o valor médio encontrado foi de 67,55 μg de LSD/selo (RSD% = 27,5). Desta forma, o método analítico apresentou desempenho satisfatório, capaz de ser utilizado como instrumento de análise para a determinação do LSD em amostras ilícitas apreendidas pelas forças policiais

    Desenvolvimento e validação de um método cromatográfico em fase gasosa para análise da 3,4-metilenodioximetanfetamina (ecstasy) e outros derivados anfetamínicos em comprimidos

    Get PDF
    The abusive use of the amphetamine derivative ecsyasy in the world come increasing in the last years. Many tablets samples kept on the streets shown the presence not only of the MDMA- 3,4-methylenedioxymethamphetamine, the main drug component but also of the MDA - 3,4- methylenedioxyamphetamine and MDEA - 3,4-methylenedioxymethylethylamphetamine. The present study sought to develop and validate an analytical method for determination of MDMA, MDA and MDEA in tablets to be accessible for the most small or medium laboratories of toxicology of the development countries as Brazil. It was chosen for development and validation a gas chromatography method with flame ionization detection. The analytic validation results for MDMA, MDA and MDEA were linearity range of 1.0 to 500.0 µg/mL, intra and interassay coefficient of variation lower than 9.5% and quantification limit of 1.0 µg/mL. The detection limits were 0.7 µg/mL, 0.8 µg/mL and 0.6 µg/mL respectively to MDMA, MDA and MDEA. The method showed a good seletivity as the epinephrine, cocaine, amphetamine, methamphetamine, acethyl salicilic acid, diethyl barbituric acid, p-aminobenzoyl diethyl barbituric, paracetamol and caffeine presences did not interfere with the measurement of the three analytes.O uso abusivo das anfetaminas e seus derivados vêm aumentando dramaticamente nos últimos anos em diversas regiões do mundo, notando-se especial utilização do Ecstasy. A análise de amostras da droga apreendidas nas ruas evidenciou, além da presença de MDMA (3,4-metilenodioximetanfetamina), componente principal da droga, outras feniletilaminas, como a MDA (3,4-metilenodioxanfetamina) e MDEA (metilenodioximetiletilanfetamina) este último também conhecido como a droga Eve, ainda pouco difundida no Brasil. O objetivo do presente trabalho foi desenvolver e validar um método analítico confiável, prático e acessível aos laboratórios de toxicologia, de médio e pequeno porte, no Brasil e em países em desenvolvimento, para identificação separada do MDMA, MDA e MDEA. A cromatografia em fase gasosa utilizando-se coluna capilar e detector de ionização de chama foi a técnica escolhida. O método analítico apresentou para os três analitos de interesse, faixa ampla de linearidade (1,0 a 500,0 µg/mL); limites de quantificação de 1,0 µg/mL e coeficientes de variação intra e interensaio inferiores a 9,5%. Os limites de detecção estabelecidos foram 0,7 µg/mL, 0,8 µg/mL e 0,6 µg/mL, respectivamente para o MDMA, MDA e MDEA. O método foi seletivo na presença de epinefrina, cocaína, anfetamina, ácido acetilsalisílico, metanfetamina, ácido dietilbarbitúrico, p-aminobenzoil dietilbarbitúrico, paracetamol e cafeína

    Lead and cadmium levels in tea traded in the metropolitan area of Belo Horizonte

    Get PDF
    O trabalho objetivou avaliar os níveis de chumbo e cádmio, em amostras de chás, industrializados e não-industrializados, comercializados na região metropolitana de Belo Horizonte. Foram selecionados para cada caso, dois tipos de plantas, camomila e erva-mate analisadas na forma de chá-infusão e de planta-digerida. Os níveis de Pb e Cd foram determinados por espectrometria de absorção atômica com forno de grafite e corretor de background Zeeman. Os níveis médios de Pb e Cd encontrados nas amostras de chá-infusão de camomila e erva-mate estavam abaixo dos valores estabelecidos pela legislação brasileira para os metais em refrescos e refrigerantes (0,2 mg/L) e as concentrações dos metais nas amostras das plantas-digeridas de camomila (valores médios de 0,15 µg/g para Cd e de 0,42µg/g de Pb) e de erva-mate (valor médio de Pb igual a 0,53µg/g) mantiveram-se dentro das faixas consideradas como "de normalidade" pela literatura. Os níveis médios de Cd em amostras de planta-digerida de erva-mate encontrados (2,59 µg/g), no entanto, estavam acima dessa faixa. Não foi encontrada diferença significativa entre os níveis de Cd e Pb quantificados em amostras de chá-infusão industrializado e não-industrializado, tanto de camomila como de erva-mate. As concentrações dos metais nas plantas-digeridas industrializadas, tanto de camomila quanto de erva-mate, apresentam-se superiores àquelas encontradas nas plantas não industrializadas.This research aims at evaluating the levels of lead and cadmium in industrialized and non-industrialized samples of tea traded in the metropolitan area of Belo Horizonte, due to the constant use of different kinds of tea by the Brazilians. Camomile and maté have been selected and analyzed as tea-infusion and digested-plant. The levels of Pb and Cd were determined by spectrometry of atomic absorption with graphite furnace and Zeeman background corrector. The average levels of Pb and Cd in samples of camomile and maté tea-infusion were below the values established by the Brazilian legislation for metals in soft drinks (0.2 mg/L). The concentrations of metals in plant-digested camomile samples (0.15 µg/g to Cd and 0.42 µg/g to Pb) and plant-digesgted mate samples (0.53 µg/g) were considered normal according to the literature with exception of Cd levels in plant-digested maté samples (2.59 µg/g). Difference was not found significant between the levels of quantified Cd and Pb in samples of industrialized and not industrialized tea-infusion camomile and maté teas. The concentrations of metals were higher in industrialized digested-plant camomile and maté, when compared with not industrialized. There was no significant difference among tea-infusion samples

    Validação do método de Ducos modificado para a determinação do ácido trans,trans-mucônico urinário

    Get PDF
    This work was conducted in an attempt to validate a method for determination of trans,trans-muconic acid (TT-MA) by high performance liquid chromatography with UV detection. The clean-up procedure of samples involves the use of strong anionic exchange cartridges for solid phase extraction. Purified samples are injected onto a reversed phase column Lichrosorb RP 18 (250 x 4.2 mm - 5 µm) temperature of 40 ºC. The isocratic run is performed at a constant flow of 1.0 mL/min; the mobile phase consists of acetic acid 1% and methanol (90:10 v/v) pH 2.72 and the UV detector is set at 264 nm. The analytic validation results were in the linearity range of 0.006 - 10.0 µg/mL, detection and quantification limits of 0.006 µg/mL and 0.03µg/mL respectively, intra and interassay coefficient of variation 9.57% and 11.15% respectively and recovery of 86.42%. The method seems suitable for biological monitoring of subjects exposed to benzene.O presente trabalho foi realizado objetivando validar um método analítico para a determinação do ácido trans,trans-mucônico (ATTM) urinário empregando-se cromatografia líquida de alta eficiência com detecção UV. O ATTM foi previamente extraído das amostras biológicas, utilizando-se colunas de troca iônica e identificado por cromatografia líquida de alta eficiência (CLAE). O cromatógrafo foi equipado com coluna de fase reversa Lichrosorb RP 18, 5 µm (250 x 4,2 mm). A temperatura da coluna foi mantida a 40 ºC. A fase móvel utilizada foi ácido acético 1% - metanol (90-10 v/v), pH = 2,72 a um fluxo de 1 mL/min e detecção UV em comprimento de onda de 264 nm. O método apresentou linearidade instrumental (0,006 a 10,0 µg/mL), limites de detecção (0,006 µg/mL) e quantificação (0,03 µg/mL), precisão (CV intra-ensaio: 9,57%, CV interensaio: 11,15%) e recuperação (86,45%) adequados à determinação da concentração urinária de ATTM em trabalhadores expostos ao benzeno

    Avaliação do ácido trans, trans-mucônico urinário como biomarcador de exposição ao benzeno

    Get PDF
    OBJECTIVE: To assess the use of trans, trans-muconic acid as a biomarker of occupational exposure to benzene. METHODS: Trans, trans-muconic acid in urine samples of exposed (exposed group, n=36) and non-exposed (non-exposed group, n=116) workers to benzene. Urinary levels of trans, trans-muconic acid were quantified by high-performance liquid chromatography. The study sample consisted of subjects exposed to benzene in an oil refinery in Belo Horizonte, Brazil. Non-parametric statistical analysis was carried out using Kruskall-Wallis test, Mann-Whitney test and Spearman correlation at pOBJETIVO: Avaliar o uso do ácido trans, trans-mucônico urinário como biomarcador na monitorização da exposição ocupacional ao benzeno. MÉTODOS: Foi estudado o comportamento do ácido trans, trans-mucônico em amostras de urina de indivíduos expostos (N=36) e não expostos (N=116) ocupacionalmente ao solvente. A concentração urinária do ácido foi determinada por Cromatografia Líquida de Alta Eficiência. A amostra foi constituída de indivíduos expostos ao benzeno em uma refinaria de petróleo localizada em Belo Horizonte, MG. Foram empregados os testes estatísticos não-paramétricos de Kruskall-Wallis, Mann Witney e de correlação de Spearman, ao nível de significância de 0,05%. RESULTADOS: A exposição média ao benzeno dos trabalhadores selecionados foi de 0,15±0,05 mg/m³ (0,05 ppm) o que resultou em um valor médio do metabólito urinário de 0,19±0,04 mg/g de creatinina. A faixa de referência do ácido trans, trans-mucônico no grupo não exposto variou de 0,03 a 0,26 mg/g de creatinina (média de 0,10±0,08 mg/g de creatinina). Foi encontrada uma diferença significativa entre os níveis de ácido trans, trans-mucônico do grupo exposto e não exposto. Entretanto, não houve correlação entre os níveis do metabólito urinário e do benzeno no ar. Foi observada a correlação entre ácido trans, trans-mucônico e hábito de fumar no grupo de indivíduos expostos. A ingestão de álcool num período de até 48 horas antes da coleta das amostras não mostrou interferir nos níveis do metabólito nos dois grupos estudados. Foi observada a correlação entre ácido trans, trans-mucônico e idade (faixa etária de 18 a 25 anos) no grupo de não expostos. CONCLUSÕES: Os resultados obtidos evidenciaram a importância de ser mais bem avaliada a influência do hábito de fumar e da faixa etária do trabalhador nos níveis urinários do ácido trans, trans-mucônico

    Determinação simultânea dos ácidos hipúrico e metil-hipúrico urinários por métodos cromatográficos: comparação entre cromatografia líquida de alta eficiência e cromatografia gasosa capilar

    Get PDF
    O presente trabalho foi realizado objetivando-se comparar a eficiência de dois métodos analíticos, um por cromatografia líquida de alta eficiência (CLAE) e outro por cromatografia em fase gasosa com coluna capilar (CG), na determinação conjunta do ácido hipúrico (AH) e ácido metil-hipúrico (AMH) em urina de indivíduos expostos ocupacionalmente ao tolueno e xileno. Após a validação analítica foi observado que o método CLAE apresentou melhores precisão intra e interensaio, porcentagem de recuperação e sensibilidade. Amostras de urina de trabalhadores expostos aos dois solventes em fábrica de tintas-látex foram analisadas pelos dois métodos validados e os resultados avaliados estatisticamente. Não se encontrou diferença significativa entre os valores de AH superiores a 1,0 g/g de creatinina, quando determinados pelos dois métodos cromatográficos. Esta similaridade não foi repetida quando os níveis de AH eram inferiores a 1,0 g/g de creatinina. Os valores de AMH nas amostras analisadas estavam, na maioria das vezes, abaixo do limite de deteção, razão pela qual não foi realizada a comparação estatística entre os mesmos.High performance liquid chromatography and capillary gas chromatography were compared for simultaneous measurement of hyppuric and methyl hyppuric acids in urine of workers co-exposed to toluene and xilene. Quantitative advantages offered by HPLC over capillary GC method are observed: better average recovery, wider dynamic interval in calibration curve and lower detection and quantification limits mainly when MHA measurement was performed. No significant difference was found between the values of HA higher than 1.0 g/g creatinine measured by the two chromatographic procedures. Regarding to MHA concentration the methods gave similar results and there was no significant difference between the values

    Desenvolvimento e validação de um método cromatográfico em fase gasosa para análise da 3,4-metilenodioximetanfetamina (ecstasy) e outros derivados anfetamínicos em comprimidos Development and validation of a gas chromatography method for determination of ecstasy and amphetamines derivatives in tablets

    Get PDF
    O uso abusivo das anfetaminas e seus derivados vêm aumentando dramaticamente nos últimos anos em diversas regiões do mundo, notando-se especial utilização do Ecstasy. A análise de amostras da droga apreendidas nas ruas evidenciou, além da presença de MDMA (3,4-metilenodioximetanfetamina), componente principal da droga, outras feniletilaminas, como a MDA (3,4-metilenodioxanfetamina) e MDEA (metilenodioximetiletilanfetamina) este último também conhecido como a droga Eve, ainda pouco difundida no Brasil. O objetivo do presente trabalho foi desenvolver e validar um método analítico confiável, prático e acessível aos laboratórios de toxicologia, de médio e pequeno porte, no Brasil e em países em desenvolvimento, para identificação separada do MDMA, MDA e MDEA. A cromatografia em fase gasosa utilizando-se coluna capilar e detector de ionização de chama foi a técnica escolhida. O método analítico apresentou para os três analitos de interesse, faixa ampla de linearidade (1,0 a 500,0 µg/mL); limites de quantificação de 1,0 µg/mL e coeficientes de variação intra e interensaio inferiores a 9,5%. Os limites de detecção estabelecidos foram 0,7 µg/mL, 0,8 µg/mL e 0,6 µg/mL, respectivamente para o MDMA, MDA e MDEA. O método foi seletivo na presença de epinefrina, cocaína, anfetamina, ácido acetilsalisílico, metanfetamina, ácido dietilbarbitúrico, p-aminobenzoil dietilbarbitúrico, paracetamol e cafeína.<br>The abusive use of the amphetamine derivative ecsyasy in the world come increasing in the last years. Many tablets samples kept on the streets shown the presence not only of the MDMA- 3,4-methylenedioxymethamphetamine, the main drug component but also of the MDA - 3,4- methylenedioxyamphetamine and MDEA - 3,4-methylenedioxymethylethylamphetamine. The present study sought to develop and validate an analytical method for determination of MDMA, MDA and MDEA in tablets to be accessible for the most small or medium laboratories of toxicology of the development countries as Brazil. It was chosen for development and validation a gas chromatography method with flame ionization detection. The analytic validation results for MDMA, MDA and MDEA were linearity range of 1.0 to 500.0 µg/mL, intra and interassay coefficient of variation lower than 9.5% and quantification limit of 1.0 µg/mL. The detection limits were 0.7 µg/mL, 0.8 µg/mL and 0.6 µg/mL respectively to MDMA, MDA and MDEA. The method showed a good seletivity as the epinephrine, cocaine, amphetamine, methamphetamine, acethyl salicilic acid, diethyl barbituric acid, p-aminobenzoyl diethyl barbituric, paracetamol and caffeine presences did not interfere with the measurement of the three analytes

    Teores de chumbo e cádmio em chás comercializados na região metropolitana de Belo Horizonte Lead and cadmium levels in tea traded in the metropolitan area of Belo Horizonte

    Get PDF
    O trabalho objetivou avaliar os níveis de chumbo e cádmio, em amostras de chás, industrializados e não-industrializados, comercializados na região metropolitana de Belo Horizonte. Foram selecionados para cada caso, dois tipos de plantas, camomila e erva-mate analisadas na forma de chá-infusão e de planta-digerida. Os níveis de Pb e Cd foram determinados por espectrometria de absorção atômica com forno de grafite e corretor de background Zeeman. Os níveis médios de Pb e Cd encontrados nas amostras de chá-infusão de camomila e erva-mate estavam abaixo dos valores estabelecidos pela legislação brasileira para os metais em refrescos e refrigerantes (0,2 mg/L) e as concentrações dos metais nas amostras das plantas-digeridas de camomila (valores médios de 0,15 µg/g para Cd e de 0,42µg/g de Pb) e de erva-mate (valor médio de Pb igual a 0,53µg/g) mantiveram-se dentro das faixas consideradas como "de normalidade" pela literatura. Os níveis médios de Cd em amostras de planta-digerida de erva-mate encontrados (2,59 µg/g), no entanto, estavam acima dessa faixa. Não foi encontrada diferença significativa entre os níveis de Cd e Pb quantificados em amostras de chá-infusão industrializado e não-industrializado, tanto de camomila como de erva-mate. As concentrações dos metais nas plantas-digeridas industrializadas, tanto de camomila quanto de erva-mate, apresentam-se superiores àquelas encontradas nas plantas não industrializadas.<br>This research aims at evaluating the levels of lead and cadmium in industrialized and non-industrialized samples of tea traded in the metropolitan area of Belo Horizonte, due to the constant use of different kinds of tea by the Brazilians. Camomile and maté have been selected and analyzed as tea-infusion and digested-plant. The levels of Pb and Cd were determined by spectrometry of atomic absorption with graphite furnace and Zeeman background corrector. The average levels of Pb and Cd in samples of camomile and maté tea-infusion were below the values established by the Brazilian legislation for metals in soft drinks (0.2 mg/L). The concentrations of metals in plant-digested camomile samples (0.15 µg/g to Cd and 0.42 µg/g to Pb) and plant-digesgted mate samples (0.53 µg/g) were considered normal according to the literature with exception of Cd levels in plant-digested maté samples (2.59 µg/g). Difference was not found significant between the levels of quantified Cd and Pb in samples of industrialized and not industrialized tea-infusion camomile and maté teas. The concentrations of metals were higher in industrialized digested-plant camomile and maté, when compared with not industrialized. There was no significant difference among tea-infusion samples
    corecore