38 research outputs found

    Fuel economy analysis of part-load variable camshaft timing strategies in two modern small-capacity spark ignition engines

    Get PDF
    Variable Camshaft Timing strategies have been investigated at part-load operating conditions in two 3-cylinder, 1.0-litre, Spark Ignition engines. The two small-size engines are different variants of the same 4-valve/cylinder, pent-roof design platform. The first engine is naturally aspirated, port fuel injection and features high nominal compression ratio of 12:1. The second one is the turbo-charged, direct injection version, featuring lower compression ratio of 10:1. The aim of the investigation has been to identify optimal camshaft timing strategies which maximise engine thermal efficiency through improvements in brake specific fuel consumption at fixed engine load. The results of the investigation show that the two engines demonstrate consistent thermal efficiency response to valve timing changes in the low and mid part-load envelope, up to a load of 4 bar BMEP. At the lower engine loads investigated, reduced intake valve opening advance limits the hot burned gas internal recirculation, while increasingly retarded exhaust valve opening timing favours engine efficiency through greater effective expansion ratio. At mid load (4 bar BMEP), a degree of intake advance becomes beneficial, owing mostly to the associated intake de-throttling. In the upper part-load domain, for engine load of 5 bar BMEP and above, the differences between the two engines determine very different efficiency response to the valve timing setting. The lower compression ratio engine continues to benefit from advanced intake valve timing, with a moderate degree of exhaust timing retard, which minimises the exhaust blow-down losses. The higher compression ratio engine is knock-limited, forcing the valve timing strategy towards regions of lower intake advance and lower hot gas recirculation. The theoretical best valve timing strategy determined peak fuel economy improvements in excess of 8% for the port fuel injection engine; the peak improvement was 5% for the more efficient direct injection engine platform

    Indicators Associated With Job Morale Among Physicians and Dentists in Low-Income and Middle-Income Countries: A Systematic Review and Meta-analysis.

    Get PDF
    Importance: Improving health care in low- and middle-income countries (LMICs) requires a workforce with positive job morale. However, the level of job morale in this population remains unclear. Objective: To analyze studies measuring the job morale of physicians and dentists working in LMICs, using levels of job burnout, job satisfaction, and job motivation as indicators of job morale. Data Sources: A comprehensive search of Scopus, PubMed, PsycINFO, EMBASE, Web of Science, and the Cochrane Library, from database inception to October 30, 2018, and gray literature was performed. Study Selection: Studies were eligible if at least 50% of the sample were qualified physicians and/or dentists working in public health care settings in LMICs. Three indicators of job morale in this population were used: job burnout, job satisfaction, and job motivation. Of 12 324 records reviewed, 79 studies were included in the systematic review and 59 were eligible for the meta-analysis. Data Extraction And Synthesis: Data were extracted independently by several investigators in accordance with the Meta-analyses of Observational Studies in Epidemiology (MOOSE) reporting guidelines. Random-effects meta-analyses, planned subgroup analyses, and metaregression were performed. The Quality Assessment Tool for Observational Cohort and Cross-Sectional Studies was used to assess bias. Main Outcomes and Measures: Levels of job burnout, job satisfaction, and job motivation as indicators of job morale. Results: Overall, 12 324 records were identified. Of them, 80 records, representing 79 studies and involving 45 714 participants across 37 LMICs, met the inclusion criteria for the review; however, only 3 were from low-income countries. In 21 studies with 9092 participants working mainly in middle-income countries, 32% (95% CI, 27%-38%; I2 = 95.32%; P < .001) reported job burnout, and in 20 studies with 14 113 participants, 60% (95% CI, 53%-67%; I2 = 98.21%; P < .001) were satisfied with their job overall. Sufficient data were not available for a meta-analysis of job motivation. Conclusions and Relevance: The findings suggest that, among physicians and dentists working mainly in middle-income countries, more than half reported having positive job morale. Positive job morale among physicians and dentists may help with recruitment and retention and thus support programs for improving health care in LMICs

    Steps toward determination of the size and structure of the broad-line region in active galactic nuclei. 5: Variability of the ultraviolet continuum and emission lines of NGC 3783

    Get PDF
    We report on the results of intensive ultraviolet spectral monitoring of the Seyfert 1 galaxy NGC 3783. The nucleus of NGC 3783 was observed with the International Ultraviolet Explorer satellite on a regular basis for a total of 7 months, once every 4 days for the first 172 days and once every other day for the final 50 days. Significant variability was observed in both continuum and emission-line fluxes. The light curves for the continuum fluxes exhibited two well-defined local minima or 'dips,' the first lasting is less than or approximately 20 days and the second is less than or approximately 4 days, with additional episodes of relatively rapid flickering of approximately the same amplitude. As in the case of NGC 5548 (the only other Seyfert galaxy that has been the subject of such an intensive, sustained monitoring effort), the largest continuum variations were seen at the shortest wavelengths, so that the continuum became 'harder' when brighter. The variations in the continuum occurred simultaneously at all wavelengths (delta(t) is less than 2 days). Generally, the amplitude of variability of the emission lines was lower than (or comparable to) that of the continuum. Apart from Mg II (which varied little) and N V (which is relatively weak and badly blended with Ly(alpha), the light curves of the emission lines are very similar to the continuum light curves, in each case with a small systematic delay or 'lag.' As for NGC 5548, the highest ionization lines seem to respond with shorter lags than the lower ionization lines. The lags found for NGC 3783 are considerably shorter than those obtained for NGC 5548, with values of (formally) approximately 0 days for He II + O III), and approximately 4 days for Ly(alpha) and C IV. The data further suggest lags of approximately 4 days for Si IV + O IV) and 8-30 days for Si III + C III). Mg II lagged the 1460 A continuum by approximately 9 days, although this result depends on the method of measuring the line flux and may in fact be due to variability of the underlying Fe II lines. Correlation analysis further shows that the power density spectrum contains substantial unresolved power over timescales of is less than or approximately 2 days, and that the character of the continuum variability may change with time

    Il telescopio Cauchoix dell’Osservatorio Astronomico del Collegio Romano

    No full text
    Il rifrattore acromatico Cauchoix, da 16 cm di apertura, acquisito dall'Osservatorio Astronomico del Collegio Romano nel 1825, è stato uno strumento fondamentale nella storia dell'astrofisica. Infatti nella seconda metà dell'800 Angelo Secchi, accoppiandolo col prisma obiettivo, lo utilizzò per ottenere la prima classificazione spettrale delle stelle. Installato su una nuova montatura equatoriale nel 1885 il telescopio è rimasto in servizio fino al 1980, quando fu smantellato. Recentemente abbiamo ritrovato il suo obiettivo di cui si erano perse le tracce per più di trent'anni. Questo ritrovamento ha permesso di ricostruire la configurazione meccanica e ottica dello strumento così come era al tempo di Secchi. Il telescopio è oggi esposto presso l'Osservatorio Astronomico di Roma a Monte Porzio Catone

    A serach for carbon stars in the AFGL catalogue

    No full text
    A comparison between theGeneral Catalogue of Cool Carbon Stars (CCS) and theAFGL Catalogue has been performed. Eighty-five stars have been found in common between the two lists. Eighty-four stars which were present in Baumert's comparison between CCS and the 2 μ Sky Survey have no counterpart in the AFGL. Four new tentative identifications are given. The analysis of the two colours diagrams K-[4.2 μ] vs. I-K and I-[4.2 μ] vs. [4.2 μ]-[11 μ] led to the conclusion that all the infrared emission from the sources seems to come from a single circumstellar shell
    corecore