48 research outputs found

    N-Benzyl-N-(2-meth­oxy­phen­yl)benzene­sulfonamide

    Get PDF
    In the title mol­ecule, C20H19NO3S, the dihedral angle between the phenyl rings is 48.93 (18)°, and they make dihedral angles of 38.37 (17) and 86.50 (19)° with the benzene ring. A weak intra­molecular C—H⋯O inter­action might stabilize the mol­ecular conformation. In the crystal, weak π–π stacking inter­actions between the benzene rings [centroid–centroid distance = 3.774 (2) Å] may help to establish the packing

    Heritability estimation of silver carp (Hypophthalmichthys molitrix) harvest traits using microsatellite based parentage assignment

    Get PDF
    Silver carp accounts for the largest biomass production of any finfish aquaculture species in the world. In spite of its great importance as an aquacultural species, very little is known about the genetic parameters of its commercially important traits. As an initial step towards developing a selective breeding programme, heritability of harvest weight and length was estimated for a silver carp stock maintained in the NFRDMP (North West Fisheries Resource Development and Management Project) hatchery in Bangladesh. Three sets of partial factorial matings were performed (12 sires and 12 dams in each set) to produce full and half-sib families for this study. Offspring from all families produced in a set were reared communally for six months and then weighed and measured upon harvesting. Ten silver carp microsatellite markers were included in two multiplex PCR systems and were used to assign parentage to the individuals. Out of 331 offspring, 96.3% could be assigned to a single family. Statistical analyses to partition the variance components for weight and length data were carried out by the REML (Restricted Maximum Likelihood) method. Heritability for harvest weight was estimated to be 0.67 (confidence interval: 0.42-0.93) and for harvest length 0.51 (confidence interval: 0.29-0.78). Despite the limited sample size, the moderate to high heritability estimates suggest that this population should respond rapidly to selective breeding for increased harvest size. In addition to this first report of quantitative genetic parameters in silver carp, this paper also describes two novel multiplexes of silver carp microsatellite markers for parentage assignment and discusses the effects of the partial factorial mating design in maintaining effective population size in this species

    Chronic inflammatory demyelinating polyneuropathy as a paraneoplastic manifestation of colorectal carcinoma: What do we know?

    Get PDF
    The pathogenesis of chronic inflammatory demyelinating polyneuropathy (CIDP) remains highly debated among experts. In recent times, literature has divulged a riveting yet plausible association between colorectal carcinoma and CIDP as its paraneoplastic ramification. Initially, research suggested that chronic inflammatory demyelinating polyneuropathy (CIDP) was caused solely by macrophages. However, recent studies have insinuated towards an alternative pathogenesis, one involving autoantibodies against paranodal junction proteins. These two distinct mechanisms are the primary contenders responsible for the development of CIDP, rendering it an elusive paraneoplastic manifestation of colorectal carcinoma.</p

    Characterisation of microsatellite loci in silver carp and cross amplification in other cyprinid species

    Get PDF
    Captive populations of silver carp (Hypophthalmichthys molitrix), a major aquaculture species in Asia, would undoubtedly benefit from genetic monitoring and improvement programs. We report the isolation and preliminary characterization of 16 microsatellite loci derived from both conventional and microsatellite-enriched libraries. Inheritance studies confirmed the allelic nature of observed polymorphisms at all loci, while identifying null alleles at two loci. These loci, having varying degrees of polymorphism, should provide useful markers for applied genetic studies. A high degree of cross-amplification among 10 other cyprinid species suggests that these loci may have more widespread utility

    Safety and Efficacy of Hydroxychloroquine in COVID-19: A Systematic Review and Meta-Analysis

    Get PDF
    Background: During the initial phases of the coronavirus disease 2019 (COVID-19) epidemic, there was an unfounded fervor surrounding the use of hydroxychloroquine (HCQ); however, recently, the Centers for Disease Control and Prevention (CDC) has recommended against routine use of HCQ outside of study protocols citing possible adverse outcomes. Methods: Multiple databases were searched to identify articles on COVID-19. An unadjusted odds ratio (OR) was used to calculate the safety and efficacy of HCQ on a random effect model. Results: Twelve studies comprising 3,912 patients (HCQ 2,512 and control 1400) were included. The odds of all-cause mortality (OR: 2.23, 95% confidence interval (CI): 1.58 - 3.13, P value \u3c 0.00001) were significantly higher in patients on HCQ compared to patients on control agent. The response to therapy assessed by negative repeat polymerase chain reaction (PCR) (OR: 1.83, 95% CI: 0.50 - 6.75, P = 0.36), radiological resolution (OR: 1.98, 95% CI: 0.47 - 8.36, P value = 0.36) and the need for invasive mechanical ventilation (IMV) (OR: 1.21, 95% CI: 0.34 - 4.33, P value = 0.76) were identical between the two groups. Overall, four times higher odds of net adverse events (NAEs) were observed in the HCQ group (OR: 4.59, 95% CI 1.73 - 12.20, P value = 0.02). The measures for individual safety endpoints were also numerically lower in the control arm; however, none of these values reached the level of statistical significance. Conclusions: HCQ might offer no benefits in terms of decreasing the viral load and radiological improvement in patients with COVID-19. HCQ appears to be associated with higher odds of all-cause mortality and NAEs

    Turnpike Catheter failure, causes and mechanisms: Insights from the MAUDE database.

    Get PDF
    Background: The Turnpike catheters (Teleflex, Wayne, PA, USA) is a microcatheter that was approved by the Food and Drug Administration in November 2014 to be used to access discrete regions of the coronary and peripheral vasculature. Methods: The Manufacturer and User Facility Device Experience (MAUDE) database was queried for reports of the Turnpike catheters from March 2015 through August 2021. Results: A total of 216 reports were found during the study period. After excluding duplicate reports (n = 21), our final cohort included 195 reports. The most common failure mode was catheter tip break or detachment (83%, n = 165) which was significantly associated with over-torquing (p-value = 0.025). The most common clinical consequence was the entrapment of the catheter (33%, n = 65), followed by vessel injury (7.8% n = 15) and vessel occlusion (3.6%, n = 7). Most patients had no consequences (47.0%, n = 93) or recovered (11%, n = 22). A total of 4 deaths were reported. 35.8% of reports (n = 69) specified the presence of severe calcification in the target vessel. Over torquing by interventionists was reported in 33.2% of events (n = 64). Conclusion: Despite clinical trials demonstrating the safety of the Turnpike catheters, complications can still occur. These data serve to inform operators about potentional risks and complications associated with the use of the device. Physicians should avoid over-torqueing which seems to be the most common mechanism for device complications

    Clinical and angiographic success and safety comparison of coronary intravascular lithotripsy: An updated meta-analysis

    Get PDF
    Background Intravascular lithotripsy (IVL) can be used to assist stent deployment in severe coronary artery calcifications (CAC). Methods Studies employing IVL for CAC lesions were included. The primary outcomes included clinical and angiographic success. The secondary outcomes, including lumen gain, maximum calcium thickness, and calcium angle at the final angiography site, minimal lumen area site, and minimal stent area site, were analyzed by the random-effects model to calculate the pooled standardized mean difference. Tertiary outcomes included safety event ratios. Results Seven studies (760 patients) were included. The primary outcomes: pooled clinical and angiographic success event ratio parentage of IVL was 94.4% and 94.8%, respectively. On a random effect model for standard inverse variance for secondary outcomes showed: minimal lumen diameter increase with IVL was 4.68 mm (p-value < 0.0001, 95% CI 1.69–5.32); diameter decrease in the stenotic area after IVL session was −5.23 mm (95 CI –22.6–12.8). At the minimal lumen area (MLA) and final minimal stent area (MSA) sites, mean lumen area gain was 1.42 mm2 (95% CI 1.06–1.63; p < 0.00001) and 1.34 mm2 (95% CI 0.71–1.43; p < 0.00001), respectively. IVL reduced calcium thickness at the MLA site (SMD −0.22; 95% CI −0.40–0.04; P = 0.02); calcium angle was not affected at the MLA site. The tertiary outcomes: most common complication was major adverse cardiovascular events (n = 48/669), and least common complication was abrupt closure of the vessel (n = 1/669). Conclusions Evidence suggests that IVL safely and effectively facilitates stent deployment with high angiographic and clinical success rates in treating severely calcified coronary lesions

    Cardiovascular outcomes and trends of Transcatheter vs. Surgical aortic valve replacement among octogenarians with heart failure: A Propensity Matched national cohort analysis.

    Get PDF
    Background: Heart failure (HF) is a complex clinical syndrome with symptoms and signs that result from any structural or functional impairment of ventricular filling or ejection of blood. Limited data is available regarding the in-hospital outcomes of TAVR compared to SAVR in the octogenarian population with HF. Methods: The National Inpatient Sample (NIS) database was used to compare TAVR versus SAVR among octogenarians with HF. The primary outcome was in-hospital mortality. The secondary outcome included acute kidney injury (AKI), cerebrovascular accident (CVA), post-procedural stroke, major bleeding, blood transfusions, sudden cardiac arrest (SCA), cardiogenic shock (CS), and mechanical circulatory support (MCS). Results: A total of 74,995 octogenarian patients with HF (TAVR-HF n = 64,890 (86.5%); SAVR n = 10,105 (13.5%)) were included. The median age of patients in TAVR-HF and SAVR-HF was 86 (83-89) and 82 (81-84) respectively. TAVR-HF had lower percentage in-hospital mortality (1.8% vs. 6.9%;p < 0.001), CVA (2.5% vs. 3.6%; p = 0.009), SCA (9.9% vs. 20.2%; p < 0.001), AKI (17.4% vs. 40.8%); p < 0.001), major transfusion (26.4% vs 67.3%; p < 0.001), CS (1.8% vs 9.8%; p < 0.001), and MCS (0.8% vs 7.3%; p < 0.001) when compared to SAVR-HF. Additionally, post-procedural stroke and major bleeding showed no significant difference. The median unmatched total charges for TAVR-HF and SAVR-HF were 194,561and246,100 and 246,100 respectively. Conclusion: In this nationwide observational analysis, TAVR is associated with an improved safety profile for octogenarians with heart failure (both preserved and reduced ejection fraction) compared to SAVR

    Clinical and angiographic success and safety comparison of coronary intravascular lithotripsy: An updated meta-analysis

    Get PDF
    Background: Intravascular lithotripsy (IVL) can be used to assist stent deployment in severe coronary artery calcifications (CAC). Methods: Studies employing IVL for CAC lesions were included. The primary outcomes included clinical and angiographic success. The secondary outcomes, including lumen gain, maximum calcium thickness, and calcium angle at the final angiography site, minimal lumen area site, and minimal stent area site, were analyzed by the random-effects model to calculate the pooled standardized mean difference. Tertiary outcomes included safety event ratios. Results: Seven studies (760 patients) were included. The primary outcomes: pooled clinical and angiographic success event ratio parentage of IVL was 94.4% and 94.8%, respectively. On a random effect model for standard inverse variance for secondary outcomes showed: minimal lumen diameter increase with IVL was 4.68 mm (p-value \u3c 0.0001, 95% CI 1.69-5.32); diameter decrease in the stenotic area after IVL session was -5.23 mm (95 CI -22.6-12.8). At the minimal lumen area (MLA) and final minimal stent area (MSA) sites, mean lumen area gain was 1.42 mm2 (95% CI 1.06-1.63; p \u3c 0.00001) and 1.34 mm2 (95% CI 0.71-1.43; p \u3c 0.00001), respectively. IVL reduced calcium thickness at the MLA site (SMD -0.22; 95% CI -0.40-0.04; P = 0.02); calcium angle was not affected at the MLA site. The tertiary outcomes: most common complication was major adverse cardiovascular events (n = 48/669), and least common complication was abrupt closure of the vessel (n = 1/669). Conclusions: Evidence suggests that IVL safely and effectively facilitates stent deployment with high angiographic and clinical success rates in treating severely calcified coronary lesions

    Cardiovascular Outcomes and Trends of Transcatheter vs. Surgical Aortic Valve Replacement Among Octogenarians With Heart Failure: A Propensity Matched National Cohort Analysis

    Get PDF
    Background: Heart failure (HF) is a complex clinical syndrome with symptoms and signs that result from any structural or functional impairment of ventricular filling or ejection of blood. Limited data is available regarding the in-hospital outcomes of TAVR compared to SAVR in the octogenarian population with HF. Methods: The National Inpatient Sample (NIS) database was used to compare TAVR versus SAVR among octogenarians with HF. The primary outcome was in-hospital mortality. The secondary outcome included acute kidney injury (AKI), cerebrovascular accident (CVA), post-procedural stroke, major bleeding, blood transfusions, sudden cardiac arrest (SCA), cardiogenic shock (CS), and mechanical circulatory support (MCS). Results: A total of 74,995 octogenarian patients with HF (TAVR-HF n = 64,890 (86.5%); SAVR n = 10,105 (13.5%)) were included. The median age of patients in TAVR-HF and SAVR-HF was 86 (83-89) and 82 (81-84) respectively. TAVR-HF had lower percentage in-hospital mortality (1.8% vs. 6.9%;p \u3c 0.001), CVA (2.5% vs. 3.6%; p = 0.009), SCA (9.9% vs. 20.2%; p \u3c 0.001), AKI (17.4% vs. 40.8%); p \u3c 0.001), major transfusion (26.4% vs 67.3%; p \u3c 0.001), CS (1.8% vs 9.8%; p \u3c 0.001), and MCS (0.8% vs 7.3%; p \u3c 0.001) when compared to SAVR-HF. Additionally, post-procedural stroke and major bleeding showed no significant difference. The median unmatched total charges for TAVR-HF and SAVR-HF were 194,561and246,100 and 246,100 respectively. Conclusion: In this nationwide observational analysis, TAVR is associated with an improved safety profile for octogenarians with heart failure (both preserved and reduced ejection fraction) compared to SAVR
    corecore