12 research outputs found

    Validation and Verification of High-Fidelity Simulations of Thoracic Stent-Graft Implantation

    Get PDF
    Thoracic Endovascular Aortic Repair (TEVAR) is the preferred treatment option for thoracic aortic pathologies and consists of inserting a self-expandable stent-graft into the pathological region to restore the lumen. Computational models play a significant role in procedural planning and must be reliable. For this reason, in this work, high-fidelity Finite Element (FE) simulations are developed to model thoracic stent-grafts. Experimental crimp/release tests are performed to calibrate stent-grafts material parameters. Stent pre-stress is included in the stent-graft model. A new methodology for replicating device insertion and deployment with explicit FE simulations is proposed. To validate this simulation, the stent-graft is experimentally released into a 3D rigid aortic phantom with physiological anatomy and inspected in a computed tomography (CT) scan at different time points during deployment with an ad-hoc set-up. A verification analysis of the adopted modeling features compared to the literature is performed. With the proposed methodology the error with respect to the CT is on average 0.92 +/- 0.64%, while it is higher when literature models are adopted (on average 4.77 +/- 1.83%). The presented FE tool is versatile and customizable for different commercial devices and applicable to patient-specific analyses

    Guidelines on the diagnosis, treatment and management of visceral and renal arteries aneurysms: a joint assessment by the Italian Societies of Vascular and Endovascular Surgery (SICVE) and Medical and Interventional Radiology (SIRM)

    Get PDF
    : The objective of these Guidelines is to provide recommendations for the classification, indication, treatment and management of patients suffering from aneurysmal pathology of the visceral and renal arteries. The methodology applied was the GRADE-SIGN version, and followed the instructions of the AGREE quality of reporting checklist. Clinical questions, structured according to the PICO (Population, Intervention, Comparator, Outcome) model, were formulated, and systematic literature reviews were carried out according to them. Selected articles were evaluated through specific methodological checklists. Considered Judgments were compiled for each clinical question in which the characteristics of the body of available evidence were evaluated in order to establish recommendations. Overall, 79 clinical practice recommendations were proposed. Indications for treatment and therapeutic options were discussed for each arterial district, as well as follow-up and medical management, in both candidate patients for conservative therapy and patients who underwent treatment. The recommendations provided by these guidelines simplify and improve decision-making processes and diagnostic-therapeutic pathways of patients with visceral and renal arteries aneurysms. Their widespread use is recommended

    Sex-related Outcomes after Thoracic Endovascular Repair for intact isolated Descending Thoracic Aortic Aneurysm: A Retrospective Cohort Study

    No full text
    OBJECTIVE: To evaluate the association between sex and outcomes following TEVAR for intact isolated descending thoracic aortic aneurysms (iiDTAA). SUMMARY BACKGROUND DATA: Data regarding sex-related long-term outcomes after TEVAR for iiDTAA are limited and conflicting results regarding perioperative outcomes have been reported. METHODS: We included all TEVAR for iiDTAA between 2014-2019 in the Vascular Quality Initiative linked to Medicare claims, allowing reliable assessment of long-term outcome data. Primary outcomes included 5-year mortality, reinterventions, and ruptures of the thoracic aorta. Secondarily we assessed perioperative outcomes. RESULTS: We identified 685 patients, of which 54% were females. Females had higher aortic size index (females vs. males: 3.31 [IQR, 2.81-3.85] cm/m2 vs. 2.93 [IQR, 2.42-3.36] cm/m2; P.05). CONCLUSIONS: Our findings suggest that females who undergo TEVAR for iiDTAA have similar 5-year and perioperative outcomes as compared with males

    Comparison of Two Generations of Thoracic Aortic Stent Grafts and Their Impact on Aortic Stiffness in an Ex Vivo Porcine ModelWhat this paper adds

    No full text
    Objective: Little is known about the cardiovascular changes after TEVAR and regarding the impact on aortic stiffness for different stent graft generations specifically, following changes in device design. The present study evaluated the stent graft induced aortic stiffening of two generations of the Valiant thoracic aortic stent graft. Methods: This was an ex vivo porcine investigation using an experimental mock circulatory loop. Thoracic aortas of young healthy pigs were harvested and connected to the mock circulatory loop. At a 60 bpm heart rate and stable mean arterial pressure, baseline aortic characteristics were obtained. Pulse wave velocity (PWV) was calculated before and after stent graft deployment. Paired and independent sample t tests or their non-parametric alternatives were performed to test for differences where appropriate. Results: Twenty porcine thoracic aortas were divided into two equal subgroups, in which a Valiant Captivia or a Valiant Navion stent graft was deployed. Both stent grafts were similar in diameter and length. Baseline aortic characteristics did not differ between the subgroups. Mean arterial pressure values did not change after either stent graft, while pulse pressures increased statistically significantly after Captivia (mean 44 ± 10 mmHg to 51 ± 13 mmHg, p = .002) but not after Navion. Mean baseline PWV increased after both Captivia (4.4 ± 0.6 m/s to 4.8 ± 0.7 m/s, p = .007) and Navion (4.6 ± 0.7 m/s to 4.9 ± 0.7 m/s, p = .002). There was no statistically significant difference in the mean percentage increase in PWV for either subgroup (8 ± 4% vs. 6 ± 4%, p = .25). Conclusion: These experimental findings showed no statistically significant difference in the percentage increase of aortic PWV after either stent graft generation and confirm that TEVAR increases aortic PWV. As a surrogate for aortic stiffness, this calls for further improvements in future thoracic aortic stent graft designs regarding device compliance
    corecore