32 research outputs found

    Hybrid Synthetic Receptors on MOSFET Devices for Detection of Prostate Specific Antigen in Human Plasma

    Get PDF
    The study reports the use of extended gate field-effect transistors (FET) for the label-free and sensitive detection of prostate cancer (PCa) biomarkers in human plasma. The approach integrates for the first time hybrid synthetic receptors comprising of highly selective aptamer-lined pockets (apta-MIP) with FETs for sensitive detection of prostate specific antigen (PSA) at clinically relevant concentrations. The hybrid synthetic receptors were constructed by immobilizing an aptamer–PSA complex on gold and subjecting it to 13 cycles of dopamine electropolymerization. The polymerization resulted in the creation of highly selective polymeric cavities that retained the ability to recognize PSA post removal of the protein. The hybrid synthetic receptors were subsequently used in an extended gate FET setup for electrochemical detection of PSA. The sensor was reported to have a limit of detection of 0.1 pg/mL with a linear detection range from 0.1 pg/mL to 1 ng/mL PSA. Detection of 1–10 pg/mL PSA was also achieved in diluted human plasma. The present apta-MIP sensor developed in conjunction with FET devices demonstrates the potential for clinical application of synthetic hybrid receptors for the detection of clinically relevant biomarkers in complex samples

    Aptamer-MIP hybrid receptor for highly sensitive electrochemical detection of prostate specific antigen

    Get PDF
    This study reports the design and evaluation of a new synthetic receptor sensor based on the amalgamation of biomolecular recognition elements and molecular imprinting to overcome some of the challenges faced by conventional protein imprinting. A thiolated DNA aptamer with established affinity for prostate specific antigen (PSA) was complexed with PSA prior to being immobilised on the surface of a gold electrode. Controlled electropolymerisation of dopamine around the complex served to both entrap the complex, holding the aptamer in, or near to, it’s binding conformation, and to localise the PSA binding sites at the sensor surface. Following removal of PSA, it was proposed that the molecularly imprinted polymer (MIP) cavity would act synergistically with the embedded aptamer to form a hybrid receptor (apta-MIP), displaying recognition properties superior to that of aptamer alone. Electrochemical impedance spectroscopy (EIS) was used to evaluate subsequent rebinding of PSA to the apta-MIP surface. The apta-MIP sensor showed high sensitivity with a linear response from 100 pg/ml to 100 ng/ml of PSA and a limit of detection of 1 pg/ml, which was three-fold higher than aptamer alone sensor for PSA. Furthermore, the sensor demonstrated low cross-reactivity with a homologous protein (human Kallikrein 2) and low response to human serum albumin (HSA), suggesting possible resilience to the non-specific binding of serum proteins

    Electronic structure of superconducting graphite intercalate compounds: The role of the interlayer state

    Full text link
    Although not an intrinsic superconductor, it has been long--known that, when intercalated with certain dopants, graphite is capable of exhibiting superconductivity. Of the family of graphite--based materials which are known to superconduct, perhaps the most well--studied are the alkali metal--graphite intercalation compounds (GIC) and, of these, the most easily fabricated is the C8{}_8K system which exhibits a transition temperature Tc0.14\bm{T_c\simeq 0.14} K. By increasing the alkali metal concentration (through high pressure fabrication techniques), the transition temperature has been shown to increase to as much as 5\bm 5 K in C2{}_2Na. Lately, in an important recent development, Weller \emph{et al.} have shown that, at ambient conditions, the intercalated compounds \cyb and \cca exhibit superconductivity with transition temperatures Tc6.5\bm{T_c\simeq 6.5} K and 11.5\bm{11.5} K respectively, in excess of that presently reported for other graphite--based compounds. We explore the architecture of the states near the Fermi level and identify characteristics of the electronic band structure generic to GICs. As expected, we find that charge transfer from the intercalant atoms to the graphene sheets results in the occupation of the π\bm\pi--bands. Yet, remarkably, in all those -- and only those -- compounds that superconduct, we find that an interlayer state, which is well separated from the carbon sheets, also becomes occupied. We show that the energy of the interlayer band is controlled by a combination of its occupancy and the separation between the carbon layers.Comment: 4 Figures. Please see accompanying experimental manuscript "Superconductivity in the Intercalated Graphite Compounds C6Yb and C6Ca" by Weller et a

    素数集合上の絶対シンプレクティック構造と絶対ワイル代数

    Get PDF
    The purpose of this paper is to give the absolute mathematics for the prime set. Absolute mathematics was introduced by N.Kurokawa in order to solve the Riemann conjecture. One of the idea for absolute mathematics is the prime differential on the rational integer Z. We analyze all possible arithmetic generalizations of symplectic and contact structures on a prime set. There are two different types of structures according to the Lagrangian subspace and Legendrian subspace. Main result is that the prime set is characterized by the Lagrangian subspace of absolute symplectic space (T*P, w). We also define a notion of the absolute Weyl algebra

    Aptamer-MIP hybrid receptor for highly sensitive electrochemical detection of prostate specific antigen

    Get PDF
    This study reports the design and evaluation of a new synthetic receptor sensor based on the amalgamation of biomolecular recognition elements and molecular imprinting to overcome some of the challenges faced by conventional protein imprinting. A thiolated DNA aptamer with established affinity for prostate specific antigen (PSA) was complexed with PSA prior to being immobilised on the surface of a gold electrode. Controlled electropolymerisation of dopamine around the complex served to both entrap the complex, holding the aptamer in, or near to, it’s binding conformation, and to localise the PSA binding sites at the sensor surface. Following removal of PSA, it was proposed that the molecularly imprinted polymer (MIP) cavity would act synergistically with the embedded aptamer to form a hybrid receptor (apta-MIP), displaying recognition properties superior to that of aptamer alone. Electrochemical impedance spectroscopy (EIS) was used to evaluate subsequent rebinding of PSA to the apta-MIP surface. The apta-MIP sensor showed high sensitivity with a linear response from 100 pg/ml to 100 ng/ml of PSA and a limit of detection of 1 pg/ml, which was three-fold higher than aptamer alone sensor for PSA. Furthermore, the sensor demonstrated low cross-reactivity with a homologous protein (human Kallikrein 2) and low response to human serum albumin (HSA), suggesting possible resilience to the non-specific binding of serum proteins

    Controlling the Nanoscale Patterning of AuNPs on Silicon Surfaces

    Get PDF
    This study evaluates the effectiveness of vapour-phase deposition for creating sub-monolayer coverage of aminopropyl triethoxysilane (APTES) on silicon in order to exert control over subsequent gold nanoparticle deposition. Surface coverage was evaluated indirectly by observing the extent to which gold nanoparticles (AuNPs) deposited onto the modified silicon surface. By varying the distance of the silicon wafer from the APTES source and concentration of APTES in the evaporating media, control over subsequent gold nanoparticle deposition was achievable to an extent. Fine control over AuNP deposition (AuNPs/μm2) however, was best achieved by adjusting the ionic concentration of the AuNP-depositing solution. Furthermore it was demonstrated that although APTES was fully removed from the silicon surface following four hours incubation in water, the gold nanoparticle-amino surface complex was stable under the same conditions. Atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) were used to study these affects
    corecore