24 research outputs found

    Verifying timestamps of occultation observation systems

    Full text link
    We describe an image timestamp verification system to determine the exposure timing characteristics and continuity of images made by an imaging camera and recorder, with reference to Coordinated Universal Time (UTC). The original use was to verify the timestamps of stellar occultation recording systems, but the system is applicable to lunar flashes, planetary transits, sprite recording, or any area where reliable timestamps are required. The system offers good temporal resolution (down to 2 msec, referred to UTC) and provides exposure duration and interframe dead time information. The system uses inexpensive, off-the- shelf components, requires minimal assembly and requires no high-voltage components or connections. We also describe an application to load FITS (and other format) image files, which can decode the verification image timestamp. Source code, wiring diagrams and built applications are provided to aid the construction and use of the device.Comment: 10 pages, 7 figures, accepted to Publications of the Astronomical Society of Australia (PASA

    A Local Region of Interest Imaging Method for Electrical Impedance Tomography with Internal Electrodes

    Get PDF
    Electrical Impedance Tomography (EIT) is a very attractive functional imaging method despite the low sensitivity and resolution. The use of internal electrodes with the conventional reconstruction algorithms was not enough to enhance image resolution and accuracy in the region of interest (ROI). We propose a local ROI imaging method with internal electrodes developed from careful analysis of the sensitivity matrix that is designed to reduce the sensitivity of the voxels outside the local region and optimize the sensitivity of the voxel inside the local region. We perform numerical simulations and physical measurements to demonstrate the localized EIT imaging method. In preliminary results with multiple objects we show the benefits of using an internal electrode and the improved resolution due to the local ROI image reconstruction method. The sensitivity is further increased by allowing the surface electrodes to be unevenly spaced with a higher density of surface electrodes near the ROI. Also, we analyse how much the image quality is improved using several performance parameters for comparison. While these have not yet been studied in depth, it convincingly shows an improvement in local sensitivity in images obtained with an internal electrode in comparison to a standard reconstruction method

    Investigating the role of capacitive coupling between the operating table and the return electrode of an electrosurgery unit in the modification of the current density distribution within the patients’ body

    Get PDF
    Background: Electrosurgery units are widely employed in modern surgery. Advances in technology have enhanced the safety of these devices, nevertheless, accidental burns are still regularly reported. This study focuses on possible causes of sacral burns as complication of the use of electrosurgery. Burns are caused by local densifications of the current, but the actual pathway of current within patient's body is unknown. Numerical electromagnetic analysis can help in understanding the issue. Methods: To this aim, an accurate heterogeneous model of human body (including seventy-seven different tissues), electrosurgery electrodes, operating table and mattress was build to resemble a typical surgery condition. The patient lays supine on the mattress with the active electrode placed onto the thorax and the return electrode on his back. Common operating frequencies of electrosurgery units were considered. Finite Difference Time Domain electromagnetic analysis was carried out to compute the spatial distribution of current density within the patient's body. A differential analysis by changing the electrical properties of the operating table from a conductor to an insulator was also performed. Results: Results revealed that distributed capacitive coupling between patient body and the conductive operating table offers an alternative path to the electrosurgery current. The patient's anatomy, the positioning and the different electromagnetic properties of tissues promote a densification of the current at the head and sacral region. In particular, high values of current density were located behind the sacral bone and beneath the skin. This did not occur in the case of non-conductive operating table. Conclusion: Results of the simulation highlight the role played from capacitive couplings between the return electrode and the conductive operating table. The concentration of current density may result in an undesired rise in temperature, originating burns in body region far from the electrodes. This outcome is concordant with the type of surgery-related sacral burns reported in literature. Such burns cannot be immediately detected after surgery, but appear later and can be confused with bedsores. In addition, the dosimetric analysis suggests that reducing the capacity coupling between the return electrode and the operating table can decrease or avoid this problem

    Verifying timestamps of occultation observation systems

    No full text
    We describe an image timestamp verification system to determine the exposure timing characteristics and continuity of images made by an imaging camera and recorder, with reference to Coordinated Universal Time. The original use was to verify the timestamps of stellar occultation recording systems, but the system is applicable to lunar flashes, planetary transits, sprite recording, or any area where reliable timestamps are required. The system offers good temporal resolution (down to 2 ms, referred to Coordinated Universal Time) and provides exposure duration and interframe dead time information. The system uses inexpensive, off-the-shelf components, requires minimal assembly, and requires no high-voltage components or connections. We also describe an application to load fits (and other format) image files, which can decode the verification image timestamp. Source code, wiring diagrams, and built applications are provided to aid the construction and use of the device

    A Local Region of Interest Imaging Method for Electrical Impedance Tomography with Internal Electrodes

    No full text
    Electrical Impedance Tomography (EIT) is a very attractive functional imaging method despite the low sensitivity and resolution. The use of internal electrodes with the conventional reconstruction algorithms was not enough to enhance image resolution and accuracy in the region of interest (ROI). We propose a local ROI imaging method with internal electrodes developed from careful analysis of the sensitivity matrix that is designed to reduce the sensitivity of the voxels outside the local region and optimize the sensitivity of the voxel inside the local region. We perform numerical simulations and physical measurements to demonstrate the localized EIT imaging method. In preliminary results with multiple objects we show the benefits of using an internal electrode and the improved resolution due to the local ROI image reconstruction method. The sensitivity is further increased by allowing the surface electrodes to be unevenly spaced with a higher density of surface electrodes near the ROI. Also, we analyse how much the image quality is improved using several performance parameters for comparison. While these have not yet been studied in depth, it convincingly shows an improvement in local sensitivity in images obtained with an internal electrode in comparison to a standard reconstruction method

    How to test bioinformatics software?

    No full text
    Bioinformatics is the application of computational, mathematical and statistical techniques to solve problems in biology and medicine. Bioinformatics programs developed for computational simulation and large-scale data analysis are widely used in almost all areas of biophysics. The appropriate choice of algorithms and correct implementation of these algorithms are critical for obtaining reliable computational results. Nonetheless, it is often very difficult to systematically test these programs as it is often hard to verify the correctness of the output, and to effectively generate failure-revealing test cases. Software testing is an important process of verification and validation of scientific software, but very few studies have directly dealt with the issues of bioinformatics software testing. In this work, we review important concepts and state-of-the-art methods in the field of software testing. We also discuss recent reports on adapting and implementing software testing methodologies in the bioinformatics field, with specific examples drawn from systems biology and genomic medicine

    Hierarchische Modellsysteme zur Optimierung der Beatmungstherapie

    No full text
    With the greatest burden of infant undernutrition and morbidity in low and middle income countries (LMICs), there is a need for suitable approaches to monitor infants in a simple, low-cost and effective manner. Anthropometry continues to play a major role in characterising growth and nutritional status.We developed a range of models to aid in identifying neonates at risk of malnutrition. We first adopted a logistic regression approach to screen for a composite neonatal morbidity, low and high body fat (BF%) infants. We then developed linear regression models for the estimation of neonatal fat mass as an assessment of body composition and nutritional status.We fitted logistic regression models combining up to four anthropometric variables to predict composite morbidity and low and high BF% neonates. The greatest area under receiver-operator characteristic curves (AUC with 95% confidence intervals (CI)) for identifying composite morbidity was 0.740 (0.63, 0.85), resulting from the combination of birthweight, length, chest and mid-thigh circumferences. The AUCs (95% CI) for identifying low and high BF% were 0.827 (0.78, 0.88) and 0.834 (0.79, 0.88), respectively. For identifying composite morbidity, BF% as measured via air displacement plethysmography showed strong predictive ability (AUC 0.786 (0.70, 0.88)), while birthweight percentiles had a lower AUC (0.695 (0.57, 0.82)). Birthweight percentiles could also identify low and high BF% neonates with AUCs of 0.792 (0.74, 0.85) and 0.834 (0.79, 0.88). We applied a sex-specific approach to anthropometric estimation of neonatal fat mass, demonstrating the influence of the testing sample size on the final model performance.These models display potential for further development and evaluation in LMICs to detect infants in need of further nutritional management, especially where traditional methods of risk management such as birthweight for gestational age percentiles may be variable or non-existent, or unable to detect appropriately grown, low fat newborns

    Minimization of the Wilson’s Central Terminal voltage potential via a genetic algorithm

    No full text
    Abstract Objective The Wilson Central Terminal (WCT) is an artificially constructed reference for surface electrocardiography, which is assumed to be near zero and steady during the cardiac cycle; namely it is the simple average of the three recorded limbs (right arm, left arm and left leg) composing the Einthoven triangle and considered to be electrically equidistant from the electrical center of the heart. This assumption has been challenged and disproved in 1954 with an experiment designed just to measure and minimize WCT. Minimization was attempted varying in real time the weight resistors connected to the limbs. Unfortunately, the experiment required a very cumbersome setup and showed that WCT amplitude could not be universally minimized, in other words, the weight resistors change for each person. Taking advantage of modern computation techniques as well as of a special ECG device that aside of the standard 12-lead Electrocardiogram (ECG) can measure WCT components, we propose a software minimization (genetic algorithm) method using data recorded from 72 volunteers. Result We show that while the WCT presents average amplitude relative to lead II of 58.85% (standard deviation of 30.84%), our minimization method yields an amplitude as small as 7.45% of lead II (standard deviation of 9.04%)