29 research outputs found
Multicenter evaluation of the clinical utility of laparoscopy-assisted ERCP in patients with Roux-en-Y gastric bypass
Background and Aims
The obesity epidemic has led to increased use of Roux-en-Y gastric bypass (RYGB). These patients have an increased incidence of pancreaticobiliary diseases yet standard ERCP is not possible due to surgically altered gastroduodenal anatomy. Laparoscopic-ERCP (LA-ERCP) has been proposed as an option but supporting data are derived from single center small case-series. Therefore, we conducted a large multicenter study to evaluate the feasibility, safety, and outcomes of LA-ERCP.
Methods
This is retrospective cohort study of adult patients with RYGB who underwent LA-ERCP in 34 centers. Data on demographics, indications, procedure success, and adverse events were collected. Procedure success was defined when all of the following were achieved: reaching the papilla, cannulating the desired duct and providing endoscopic therapy as clinically indicated.
Results
A total of 579 patients (median age 51, 84% women) were included. Indication for LA-ERCP was biliary in 89%, pancreatic in 8%, and both in 3%. Procedure success was achieved in 98%. Median total procedure time was 152 minutes (IQR 109-210) with median ERCP time 40 minutes (IQR 28-56). Median hospital stay was 2 days (IQR 1-3). Adverse events were 18% (laparoscopy-related 10%, ERCP-related 7%, both 1%) with the clear majority (92%) classified as mild/moderate whereas 8% were severe and 1 death occurred.
Conclusion
Our large multicenter study indicates that LA-ERCP in patients with RYGB is feasible with a high procedure success rate comparable with that of standard ERCP in patients with normal anatomy. ERCP-related adverse events rate is comparable with conventional ERCP, but the overall adverse event rate was higher due to the added laparoscopy-related events
Endoscopic Management of Esophageal Cancer
Advances in technology and improved understanding of the pathobiology of esophageal cancer have allowed endoscopy to serve a growing role in the management of this disease. Precursor lesions can be detected using enhanced diagnostic modalities and eradicated with ablation therapy. Furthermore, evolution in endoscopic resection has provided larger specimens for improved diagnostic accuracy and offer potential for cure of early esophageal cancer. In patients with advanced esophageal cancer, endoluminal therapy can improve symptom burden and provide therapeutic options for complications such as leaks, perforations, and fistulas. The purpose of this review article is to highlight the role of endoscopy in the diagnosis, treatment, and palliation of esophageal cancer
Recommended from our members
Curative Resection of T1a Inlet Patch Adenocarcinoma With Traction-Assisted Endoscopic Submucosal Dissection.
Esophageal inlet patch (EIP) adenocarcinoma is extremely rare. We present a case of a 58-year-old man who underwent a diagnostic esophagogastroduodenoscopy for dysphagia and found to have a 2 cm polypoid mass arising from an EIP. Biopsies and staging were consistent with T1aN0M0 EIP adenocarcinoma. While surgical resection was the main method of treatment of these lesions, very few case reports have shown that endoscopic resection can successfully remove these lesions. After multidisciplinary discussion, the patient underwent curative traction-assisted endoscopic submucosal dissection-which is the first known case report to highlight the success of this technique
Endoscopic Ultrasound-Guided Fine Needle Aspiration Accurately Diagnoses Smaller Pancreatic Neuroendocrine Tumors Compared To Computer Tomography-Guided Fine Needle Aspiration
IntroductionThe role of EUS-guided FNA as a highly sensitive modality in the diagnosis of pancreatic adenocarcinoma is well documented. However, there is little published data on the role of EUS-FNA in diagnosing pancreatic neuroendocrine tumors (NETs).ObjectiveThe aim of this study is to compare the sensitivity of EUS-FNA to that of CT-FNA for diagnosing pancreatic NETs.MethodsThis is a single institution retrospective analysis of the operating characteristics of EUS-FNA and CT-FNA in detecting pancreatic NETs. Only patients with a final diagnosis of pancreatic NET were selected for this study. Procedure related data, including tumor size and location, and presence of a cytotechnologist were recorded. The results of each FNA were compared to the final clinico-pathological diagnosis to calculate sensitivity.ResultsTwenty-eight patients undergoing FNA (19 by EUS, 9 by CT) were analyzed. NETs diagnosed by EUS-FNA were smaller compared with CT-FNA (2.7 ± 0.9cm vs. 6.5 ± 2.1cm, p = 0.009) and were more often found in the pancreatic head (47.4% vs. 11.1%, p = 0.035). There were no significant differences in sensitivity between EUS-FNA and CT-FNA specimens (73.7% vs. 88.9%, p = 0.33).ConclusionEUS-guided FNA is as sensitive as CT-guided FNA in diagnosing pancreatic NETs, but its main advantage is in the diagnosis of smaller pancreatic NETs in the head of the pancreas. It may also be the preferred approach in the diagnosis of multifocal pancreatic NETs in the setting of MEN I Syndrome
Recommended from our members
Endoscopic Ultrasound-Guided Fine Needle Aspiration Accurately Diagnoses Smaller Pancreatic Neuroendocrine Tumors Compared To Computer Tomography-Guided Fine Needle Aspiration.
IntroductionThe role of EUS-guided FNA as a highly sensitive modality in the diagnosis of pancreatic adenocarcinoma is well documented. However, there is little published data on the role of EUS-FNA in diagnosing pancreatic neuroendocrine tumors (NETs).ObjectiveThe aim of this study is to compare the sensitivity of EUS-FNA to that of CT-FNA for diagnosing pancreatic NETs.MethodsThis is a single institution retrospective analysis of the operating characteristics of EUS-FNA and CT-FNA in detecting pancreatic NETs. Only patients with a final diagnosis of pancreatic NET were selected for this study. Procedure related data, including tumor size and location, and presence of a cytotechnologist were recorded. The results of each FNA were compared to the final clinico-pathological diagnosis to calculate sensitivity.ResultsTwenty-eight patients undergoing FNA (19 by EUS, 9 by CT) were analyzed. NETs diagnosed by EUS-FNA were smaller compared with CT-FNA (2.7 ± 0.9cm vs. 6.5 ± 2.1cm, p = 0.009) and were more often found in the pancreatic head (47.4% vs. 11.1%, p = 0.035). There were no significant differences in sensitivity between EUS-FNA and CT-FNA specimens (73.7% vs. 88.9%, p = 0.33).ConclusionEUS-guided FNA is as sensitive as CT-guided FNA in diagnosing pancreatic NETs, but its main advantage is in the diagnosis of smaller pancreatic NETs in the head of the pancreas. It may also be the preferred approach in the diagnosis of multifocal pancreatic NETs in the setting of MEN I Syndrome
Recommended from our members
Reviews on Current Liquid Biopsy for Detection and Management of Pancreatic Cancers
Risk factors associated with the transmission of carbapenem-resistant Enterobacteriaceae via contaminated duodenoscopes
Background and aimsThe duodenoscopes used to perform ERCP have been implicated in several outbreaks of carbapenem-resistant Enterobacteriaceae (CRE) infection. The risk factors for CRE transmission via contaminated duodenoscopes remain unclear.MethodsIn this retrospective, single-center, case-control study, all patients who underwent ERCP with either 1 of 2 contaminated duodenoscopes were evaluated. We compared the patients who acquired CRE (active infection or colonization) with those who did not.ResultsBetween October 3, 2014, and January 28, 2015, a total of 125 procedures were performed on 115 patients by using either of the contaminated duodenoscopes. Culture data were available for 104 of the 115 exposed patients (90.4%). Among these patients, 15 (14.4%) became actively infected (n = 8, 7.7%) or colonized (n = 7, 6.7%) with CRE. On univariate analysis, recent antibiotic exposure (66.7% vs 37.1%; P = .046), active inpatient status (60.0% vs 28.1%; P = .034), and a history of cholangiocarcinoma (26.7% vs 3.4%; P = .008) were patient characteristics associated with an increased risk of CRE infection. Biliary stent placement (53.3% vs 22.5%; P = .024) during ERCP was a significant procedure-related risk factor. After adjusting for cholangiocarcinoma, biliary stent placement (odds ratio 3.62; 95% confidence interval, 1.12-11.67), and active inpatient status (odds ratio 3.74; 95% confidence interval, 1.15-12.12) remained independent risk factors for CRE transmission.ConclusionsIn patients undergoing ERCP with a contaminated duodenoscope, biliary stent placement, a diagnosis of cholangiocarcinoma, and active inpatient status are associated with an increased risk of CRE transmission