22 research outputs found
Birthweight of children with isolated congenital heart disease: a sibling analysis study
ObjectiveCongenital heart disease (CHD) is associated with decreased birthweight (BW) compared to population-based references. The aim of this study was to compare the BW of isolated CHD cases to their siblings, thus controlling for unknown and unmeasured confounders within the family. MethodsAll isolated CHD cases in the Leiden University Medical Center were included (2002-2019). Generalized estimated equation models were constructed to compare BW z scores of CHD neonates with their siblings. Cases were clustered to minor or severe CHD and stratified according to the aortic flow and oxygenation to the brain. ResultsThe overall BW z score of siblings was 0.032 (n = 471). The BW z score was significantly lower in CHD cases (n = 291) compared to their siblings (-0.20, p = 0.005). The results were consistent in the subgroup analysis of severe and minor CHD (BW z score difference -0.20 and -0.10), but did not differ significantly (p = 0.63). Stratified analysis regarding flow and oxygenation showed no BW difference between the groups (p = 0.1). ConclusionIsolated CHD cases display a significantly lower BW z score compared to their siblings. As the siblings of these CHD cases show a BW distribution similar to the general population, this suggests that shared environmental and maternal influences between siblings do not explain the difference in BW.Research into fetal development and medicin
Placenta morphology and biomarkers in pregnancies with congenital heart disease - a systematic review
Impaired placentation is an important contributing factor to intra-uterine growth restriction and pre-eclampsia in fetuses with congenital heart defects (CHD). These pregnancy complications occur more frequently in pregnancies with fetal CHD. One of the most important factors influencing the life of children with CHD is neurodevelopmental delay, which seems to start already in utero. Delayed neurodevelopment in utero may be correlated or even (partly) explained by impaired placentation in CHD cases. This systematic review provides an overview of published literature on placental development in pregnancies with fetal CHD. A systematic search was performed and the Newcastle-Ottawa scale was used to access data quality. Primary outcomes were placenta size and weight, vascular and villous architecture, immunohistochemistry, angiogenic biomarkers and/or placental gene expression. A total of 1161 articles were reviewed and 21 studies were included. Studies including CHD with a genetic disorder or syndrome and/or multiple pregnancies were excluded. Lower placental weight and elevated rates of abnormal umbilical cord insertions were found in CHD. Cases with CHD more frequently showed microscopic placental abnormalities (i.e. abnormal villous maturation and increased maternal vascular malperfusion lesions), reduced levels of angiogenic biomarkers and increased levels of anti-angiogenic biomarkers in maternal serum and umbilical cord blood. Altered gene expression involved in placental development and fetal growth were found in maternal serum and CHD placentas. In conclusion, abnormal placentation is found in CHD. More extensive studies are needed to elucidate the contribution of impaired placentation to delayed neurodevelopment in CHD cases.Research into fetal development and medicin
Ultrasound markers for prediction of complex gastroschisis and adverse outcome:longitudinal prospective nationwide cohort study
Contains fulltext :
220734.pdf (Publisher’s version ) (Open Access)OBJECTIVES: To identify antenatal ultrasound markers that can differentiate between simple and complex gastroschisis and assess their predictive value. METHODS: This was a prospective nationwide study of pregnancies with isolated fetal gastroschisis that underwent serial longitudinal ultrasound examination at regular specified intervals between 20 and 37 weeks' gestation. The primary outcome was simple or complex (i.e. involving bowel atresia, volvulus, perforation or necrosis) gastroschisis at birth. Fetal biometry (abdominal circumference and estimated fetal weight), the occurrence of polyhydramnios, intra- and extra-abdominal bowel diameters and the pulsatility index (PI) of the superior mesenteric artery (SMA) were assessed. Linear mixed modeling was used to compare the individual trajectories of cases with simple and those with complex gastroschisis, and logistic regression analysis was used to estimate the strength of association between the ultrasound parameters and outcome. RESULTS: Of 104 pregnancies with isolated fetal gastroschisis included, four ended in intrauterine death. Eighty-one (81%) liveborn infants with simple and 19 (19%) with complex gastroschisis were included in the analysis. We found no relationship between fetal biometric variables and complex gastroschisis. The SMA-PI was significantly lower in fetuses with gastroschisis than in healthy controls, but did not differentiate between simple and complex gastroschisis. Both intra- and extra-abdominal bowel diameters were larger in cases with complex, compared to those with simple, gastroschisis (P /= 97.7(th) percentile on at least three occasions, not necessarily on successive examinations, was associated with an increased risk of the fetus having complex gastroschisis (relative risk, 1.56 (95% CI, 1.02-2.10); P = 0.006; positive predictive value, 50.0%; negative predictive value, 81.4%). CONCLUSIONS: This large prospective longitudinal study found that intra-abdominal bowel dilatation when present repeatedly during fetal development can differentiate between simple and complex gastroschisis; however, the positive predictive value is low, and therefore the clinical usefulness of this marker is limited. (c) 2019 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology
Using three-dimensional ultrasound in predicting complex gastroschisis:A longitudinal, prospective, multicenter cohort study
Objective: To determine whether complex gastroschisis (ie, intestinal atresia, perforation, necrosis, or volvulus) can prenatally be distinguished from simple gastroschisis by fetal stomach volume and stomach-bladder distance, using three-dimensional (3D) ultrasound. Methods: This multicenter prospective cohort study was conducted in the Netherlands between 2010 and 2015. Of seven university medical centers, we included the four centers that performed longitudinal 3D ultrasound measurements at a regular basis. We calculated stomach volumes (n = 223) using Sonography-based Automated Volume Count. The shortest stomach-bladder distance (n = 241) was determined using multiplanar visualization of the volume datasets. We used linear mixed modelling to evaluate the effect of gestational age and type of gastroschisis (simple or complex) on fetal stomach volume and stomach-bladder distance. Results: We included 79 affected fetuses. Sixty-six (84%) had been assessed with 3D ultrasound at least once; 64 of these 66 were liveborn, nine (14%) had complex gastroschisis. With advancing gestational age, stomach volume significantly increased, and stomach-bladder distance decreased (both P <.001). The developmental changes did not differ significantly between fetuses with simple and complex gastroschisis, neither for fetal stomach volume (P =.85), nor for stomach bladder distance (P =.78). Conclusion: Fetal stomach volume and stomach-bladder distance, measured during pregnancy using 3D ultrasonography, do not predict complex gastroschisis
Ultrasound markers for prediction of complex gastroschisis and adverse outcome: longitudinal prospective nationwide cohort study
Objectives: To identify antenatal ultrasound markers that can differentiate between simple and complex gastroschisis and assess their predictive value. Methods: This was a prospective nationwide study of pregnancies with isolated fetal gastroschisis that underwent serial longitudinal ultrasound examination at regular specified intervals between 20 and 37 weeks' gestation. The primary outcome was simple or complex (i.e. involving bowel atresia, volvulus, perforation or necrosis) gastroschisis at birth. Fetal biometry (abdominal circumference and estimated fetal weight), the occurrence of polyhydramnios, intra- and extra-abdominal bowel diameters and the pulsatility index (PI) of the superior mesenteric artery (SMA) were assessed. Linear mixed modeling was used to compare the individual trajectories of cases with simple and those with complex gastroschisis, and logistic regression analysis was used to estimate the strength of association between the ultrasound parameters and outcome. Results: Of 104 pregnancies with isolated fetal gastroschisis included, four ended in intrauterine death. Eighty-one (81%) liveborn infants with simple and 19 (19%) with complex gastroschisis were included in the analysis. We found no relationship between fetal biometric variables and complex gastroschisis. The SMA-PI was significantly lower in fetuses with gastroschisis than in healthy controls, but did not differentiate between simple and complex gastroschisis. Both intra- and extra-abdominal bowel diameters were larger in cases with complex, compared to those with simple, gastroschisis (P < 0.001 and P < 0.005, respectively). The presence of intra-abdominal bowel diameter ≥ 97.7th percentile on at least three occasions, not necessarily on successive examinations, was associated with an increased risk of the fetus having complex gastroschisis (relative risk, 1.56 (95% CI, 1.02–2.10); P = 0.006; positive predictive value, 50.0%; negative predictive value, 81.4%). Conclusions: This large prospective longitudinal study found that intra-abdominal bowel dilatation when present repeatedly during fetal development can differentiate between simple and complex gastroschisis; however, the positive predictive value is low, and therefore the clinical usefulness of this marker is limited
Birthweight and isolated congenital heart defects - A systematic review and meta-analysis
Background Birthweight (BW) is an important prognostic factor in newborns with congenital heart defects (CHD). Objectives To give an overview of the literature on BW z-score in children with isolated CHD. Search strategy A systematic search was performed on isolated CHD and BW in PubMed, Embase, Web of Science, COCHRANE Library and Emcare. Selection criteria Neonates with isolated CHD were included if a BW percentile, BW z-score or % small-or-gestational age (SGA) was reported. Data collection and analysis BW z-score and percentage SGA were pooled with random-effect meta-analysis. Quality and risk of bias were assessed using the modified Newcastle Ottawa Scale. Main results Twenty-three articles (27 893 cases) were included. BW z-scores were retrieved from 11 articles, resulting in a pooled z-score of -0.20 (95% CI -0.50 to 0.11). The overall pooled prevalence of SGA <10th percentile was 16.0% (95% CI 11.4-20.5; 14 studies). Subgroup analysis of major CHD showed similar results (BW z-score -0.23 and percentage SGA 16.2%). Conclusions Overall BW in isolated CHD is within range of normality but impaired, with a 1.6-fold higher risk of SGA, irrespective of the type of CHD (major CHD vs all CHD combined). Our findings underline the association between CHD and BW. The use of BW z-scores provides insight into growth of all fetuses with CHD
Learning to map 2D ultrasound images into 3D space with minimal human annotation
In fetal neurosonography, aligning two-dimensional (2D) ultrasound scans to their corresponding plane in the three-dimensional (3D) space remains a challenging task. In this paper, we propose a convolutional neural network that predicts the position of 2D ultrasound fetal brain scans in 3D atlas space. Instead of purely supervised learning that requires heavy annotations for each 2D scan, we train the model by sampling 2D slices from 3D fetal brain volumes, and target the model to predict the inverse of the sampling process, resembling the idea of self-supervised learning. We propose a model that takes a set of images as input, and learns to compare them in pairs. The pairwise comparison is weighted by the attention module based on its contribution to the prediction, which is learnt implicitly during training. The feature representation for each image is thus computed by incorporating the relative position information to all the other images in the set, and is later used for the final prediction. We benchmark our model on 2D slices sampled from 3D fetal brain volumes at 18-22 weeks' gestational age. Using three evaluation metrics, namely, Euclidean distance, plane angles and normalized cross correlation, which account for both the geometric and appearance discrepancy between the ground-truth and prediction, in all these metrics, our model outperforms a baseline model by as much as 23%, when the number of input images increases. We further demonstrate that our model generalizes to (i) real 2D standard transthalamic plane images, achieving comparable performance as human annotations, as well as (ii) video sequences of 2D freehand fetal brain scans
Subcortical segmentation of the fetal brain in 3D ultrasound using deep learning
The quantification of subcortical volume development from 3D fetal ultrasound can provide important diagnostic information during pregnancy monitoring. However, manual segmentation of subcortical structures in ultrasound volumes is time-consuming and challenging due to low soft tissue contrast, speckle and shadowing artifacts. For this reason, we developed a convolutional neural network (CNN) for the automated segmentation of the choroid plexus (CP), lateral posterior ventricle horns (LPVH), cavum septum pellucidum et vergae (CSPV), and cerebellum (CB) from 3D ultrasound. As ground-truth labels are scarce and expensive to obtain, we applied few-shot learning, in which only a small number of manual annotations (n = 9) are used to train a CNN. We compared training a CNN with only a few individually annotated volumes versus many weakly labelled volumes obtained from atlas-based segmentations. This showed that segmentation performance close to intra-observer variability can be obtained with only a handful of manual annotations. Finally, the trained models were applied to a large number (n = 278) of ultrasound image volumes of a diverse, healthy population, obtaining novel US-specific growth curves of the respective structures during the second trimester of gestation