8 research outputs found

    Synthesis of cerium, zirconium, and copper doped zinc oxide nanoparticles as potential biomaterials for tissue engineering applications

    Get PDF
    A novel eco-friendly high throughput continuous hydrothermal flow system was used to synthesise phase pure ZnO and doped ZnO in order to explore their properties for tissue engineering applications. Cerium, zirconium, and copper were introduced as dopants during flow synthesis of ZnO nanoparticles, Zirconium doped ZnO were successfully synthesised, however secondary phases of CeO and CuO were detected in X-ray diffraction (XRD). The nanoparticles were characterised using X-ray diffraction, Brunauer-Emmett-Teller (BET), Dynamic Light scattering Measurements, Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR) and RAMAN spectroscopy was used to evaluate physical, chemical, and structural properties. The change in BET surface area was also significant, the surface area increased from 11.35 (ZnO_2) to 26.18 (ZrZnO_5). However. In case of CeZnO_5 and CuZnO_5 was not significant 13.68 (CeZnO_5) and 12.16 (CuZnO_5) respectively. Cell metabolic activity analysis using osteoblast-like cells (MG63) and human embryonic derived mesenchymal stem cells (hES-MP) demonstrated that doped ZnO nanoparticles supported higher cell metabolic activity compared to cells grown in standard media with no nanoparticles added, or pure zinc oxide nanoparticles. The ZrZnO_5 demonstrated the highest cell metabolic activity and non-cytotoxicity over the duration of 28 days as compared to un doped or Ce or Cu incorporated nanoparticles. The current data suggests that Zirconium doping positively enhances the properties of ZnO nanoparticles by increasing the surface area and cell proliferation. Therefore, are potential additives within biomaterials or for tissue engineering applications

    Comparison between Restorative Materials for Pulpotomised Deciduous Molars: A Randomized Clinical Study

    No full text
    Aim: To evaluate and compare the clinical outcomes of Cention-N (CN) and stainless steel crowns (SSCs) as restorations for pulpotomised primary molars, and to study clinical and radiographic outcomes of pulpotomies restored with these materials. Methods: The study was conducted on 60 pulpotomised molars with occlusoproximal caries. These were randomly divided into two groups and restored with either stainless steel crowns or Cention-N. Clinical performance of restorations and clinical and radiographic success of pulpotomy was examined at 6, 9 and 12 months. Results: The mean scores for marginal integrity deteriorated significantly at 6, 9 and 12 months in both groups but in comparison were insignificant. The mean for proximal contact deteriorated significantly for the Cention-N group, whereas the mean for gingival health deteriorated remarkably for the stainless steel crown group at successive evaluations. No tooth in either group showed secondary caries or discomfort on biting, except for one tooth in Cention-N group which presented with secondary caries. The clinical success rate for pulpotomised molars was 100% for both groups until nine months, although this had reduced by the end of 12 months. Radiographically, the success rate was 79.3% for Cention-N, while it was 86.6% for stainless steel crowns at 12 months. There was no significant difference in clinical and radiographic success between either group. Conclusion: Cention-N and stainless steel crowns are comparable for marginal integrity. However, crowns maintain significantly better proximal contacts while Cention-N was notably better for gingival health of the restored tooth. Both materials do not show secondary caries and discomfort on biting and are comparable in clinical and radiographic success of pulpotomy at the end of one year

    Perception about Health Applications (Apps) in Smartphones towards Telemedicine during COVID-19: A Cross-Sectional Study

    No full text
    Background: The use of health applications (apps) in smartphones increased exponentially during COVID-19. This study was conducted the with the aim to understand the factors that determine the consumer's perception of health apps in smartphones towards telemedicine during COVID-19 and to test any relation between these factors and consumers towards Telemedicine in India. Methods: This questionnaire-based cross-sectional study was conducted from July 2021 to December 2021 in India. Out of 600 selected participants, 594 responded and in that 535 valid questionnaires were measured. The questionnaire consists of close-ended responses, with the first part consisting of demographic information, the second part consisting of questions associated with consumers' perceptions and the third part kept for suggestions and complaints. The questionnaire was distributed using digital platforms via WhatsApp or email. A 5-point Likert scale, ranging from strongly agree' (5) to strongly disagree (1) was used to record responses. Results: Results revealed a high response rate of 90%. The highest score was obtained for the question assessing the satisfaction of the users towards health apps [1175 = 500 (agree-4) + 675 (Strongly agree-5)]. The interface of the app scored very low, showing disagreement (514) with app functionality, and was the most common disadvantage as perceived by patients. The mean scores of reliabilities and vicinity of health services; efficacy and comprehensive health information; development and improvement of health apps and telemedicine (3.24, 3.18, 3.62, 3.49), respectively, show the difference in attraction existing between groups. There is a strong positive correlation between the variables except for efficacy and comprehensive information about health and Telemedicine (-0.249), development and improvement of health apps, and reliability and vicinity of health services (-0.344) which have a negative correlation. Conclusions: The findings of this survey reveal a positive outlook of health apps toward telemedicine. This research also found a strong forecaster of the consumer's perception of health apps in smartphones towards telemedicine. In the broad spectrum, the future of health app affiliates for telemedicine is better affected by the consumer's perception of health app efficacy. This study suggests that health app marketers develop more innovative apps to increase usage and help consumers

    Up regulation of serum L fucose glycoprotein as a diagnostic biomarker for dysplasia in oral sub mucous fibrosis patients

    No full text
    Glycoproteins, essential for cellular functions, contain monosaccharides like Levo-fucose, crucial for cell communication. Recent research highlights serum L-fucose as a potential biomarker for early detection of malignancies. Typically, serum L-fucose levels are low but rise with malignancy. This study evaluates serum L-fucose as an early biomarker in oral submucous fibrosis (OSMF) patients. Aim: Assess serum L-fucose's diagnostic potential for dysplasia in OSMF patients. Objectives: Determine the Association between Serum L Fucose Glycoprotein Levels and Dysplasia in OSF Patients.Evaluate the Diagnostic Accuracy of Serum L Fucose Glycoprotein as a Biomarker for OSF-Related Dysplasia. Methodology: Over a span of two years, this study encompassed 80 subjects, aged between 18 and 60 years, who were clinically and histopathologically identified as OSMF patients, with or without dysplastic alterations. From each participant, 5 ml of blood was collected. Following centrifugation to separate the serum, the samples were analyzed to determine the levels of Levo-fucose. Statistical analysis: Using SPSS (version 17.0), serum L-Fucose levels of the case group were compared to the control group using ANOVA. Frequencies were analyzed with the chi-square test, and Tukey’s Test was used for multiple comparisons. Significance was set at p < 0.01. Results: The analysis revealed a statistically significant disparity in the mean serum L-Fucose levels between the two groups (p < 0.01). Notably, Group II patients (those with OSMF and dysplasia) exhibited markedly elevated mean serum L-fucose levels. Conclusion: Elevated serum L-Fucose levels were observed in OSMF patients with dysplasia. Harmful habits, especially gutkha chewing, were linked to Oral Squamous Cell Carcinoma onset. Serum L-fucose can be a reliable marker for evaluating precancerous conditions

    Assessment of hearing performance of dental technicians due to the professional noise exposure

    No full text
    Abstract Background Some of the noise-intensive processes in dental laboratories include the finishing of crowns, bridges, and removable partial dentures; blowing out workpieces with steam and compressed air; and deflating casting rings. High sound pressure levels are also present in dental vibrators, polishing equipment, and sandblasters. The aim of this study was to Evaluation of the effect of noise production in dental technology laboratory on dental technician hearing capacity. Methods For this cross-sectional study, a total of 120 dental technicians were chosen. Otoscopic evaluation and the Weber test were used to establish if they had sensorineural or transmission hearing loss at 500 Hz, 1000 Hz, 2000 Hz, and 4000 Hz, respectively. Then an OAER (objective auditory evoked response) and PTA (clinical aurimeter) test were administered (Neurosoft, Russia). The whole procedure was carried out by an audiologist and an ENT specialist. Results The PTA results showed that the patient had mild hearing impairment overall, with the loss being more severe in the left ear than in the right. The OAE test results revealed that in-ear of the left side, 84.5% of subjects passed and 15.5% of subjects struggled and were referred to an ear specialist, whereas in the right ear, 82.7% of subjects passed and 17.3% struggled and were referred to an ear specialist. According to this study, in a right-handed study participant, the ear on the left side is more vulnerable than the right side. Differences in the mean hearing threshold at 4000 and 6000 Hz in the left ear were statistically significant in the groups of workers with eleven to fifteen years of practical experience and twenty-one to twenty-five years of practical experience, respectively (Minervini, et al. J Clin Med 12:2652, 2023). Conclusions A statistically meaningful threshold shift from 4000 to 6000 Hz is observed as the working experience grows, and this is suggestive of sensorineural hearing impairment brought on by the noisy dental environment

    An Investigation of the Fracture Loads Involved in the Framework of Removable Partial Dentures Using Two Types of All-Ceramic Restorations

    No full text
    Retention and support are needed for removable partial denture stability. The stability can be achieved by clasps, occlusal and cingulum rests on healthy abutment teeth. However, implants or crowns can be used to support the removable partial denture instated on unhealthy abutment teeth. This study was conducted to investigate the fracture strength of two types of all-ceramic restorations used as abutments for the removable partial denture framework. The crowns were manufactured with two types of ceramic materials: zirconia and IPS e.max Press ceramics. The metal alloy (cobalt-chrome) was cast to form the removable partial denture framework. A universal testing machine was used to evaluate the fracture strength of both ceramic crown materials. The results presented no fractures in all-ceramic crowns, but deformation of the partial denture frameworks occurred. With the limitation of this study, it can be concluded that zirconia and IPS e.max Press ceramic can be used as abutments to provide adequate support to the removable partial denture

    Surgical Protocols before and after COVID-19—A Narrative Review

    No full text
    The COVID-19 epidemic has affected not only people’s daily lives but also the working methods of clinicians, surgical procedures, open/minimally invasive procedures, operating room management, patient and healthcare worker safety, education and training. The main objective of this study was to review selected articles and determine the changes in the general surgery protocols/procedures before and after the emergence of the COVID-19 pandemic. The literature was carried out in PubMed-Medline, Cochrane Library, Embase, Scopus and Google Scholar. The terms utilised for the searches were “SARS-CoV-2”, “Surgery”, “COVID-19”, “Surgical protocol”, “Surgical recommendations” and “before and after”. A total of 236 studies were identified, out of which 41 studies were included for data extraction. Significant changes in all the articles were observed with respect to the surgeries done before, during and after the COVID-19 pandemic. Specifically, the number of elective surgeries were considerably fewer in comparison to the pre-pandemic period. Since the COVID-19 pandemic started, hospitals all throughout the world have conducted significantly fewer procedures, particularly elective/non-urgent surgeries

    Retentive Forces and Deformation of Fitting Surface in RPD Clasp Made of Polyether-Ether-Ketone (PEEK)

    No full text
    Background: Polyetheretherketone (PEEK) has provided the option to fabricate RPDs with aesthetics unlike metal RPDs, but little attention has been paid to its suitability, especially towards the retentive forces and deformation of the clasp. This study aimed to examine the retentive forces and the fitting surface (inner surface) deformation of clasps made from PEEK and compare it with cobalt–chromium (Co-Cr) clasp. Methods: Forty-two circumferential clasps (14 Co-Cr and 28 PEEK) were fabricated and divided into two groups with clasp undercuts (0.25 mm and 0.5 mm) with thicknesses of 1 mm and 1.5 mm. Each was examined for retentive forces after cycle test on its abutment for 360 cycles. Initial and final retentive forces were recorded. The fitting surface deformation was determined using 3-Matic research analysis software. Results: The results revealed that highest mean initial retentive force was of Co-Cr clasps with 0.50 mm undercut 22.26 N (±10.15 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 3.35 N (±0.72 N) and highest mean final retentive force was the Co-Cr clasps with 0.50 mm undercut 21.40 N (±9.66 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 2.71 N (±0.47 N). PEEK clasps had a lower retentive force than Co-Cr clasps with 0.50 undercut. PEEK clasps (1.5 mm) at 0.25 mm undercut had the least deformation (35.3 µm). PEEK showed significantly less deformation (p ≤ 0.014) than Co-Cr. Conclusion: The deformation of PEEK clasps fitting surface was lower than Co-Cr clasps and retentive forces were close to the Co-Cr clasps, suggesting the use of PEEK as an aesthetic clasp option for RPD framework
    corecore