10 research outputs found
Response [letter to the editor]
[Extract] To the Editor: We thank Eston and colleagues (2) for their scrutiny of our work on the use of automated HR feedback to regulate exercise behavior, and we offer the following comments in response to their observations. Specifically, we comment on a nomenclature issue related to exercise intensity in our study as well as issues surrounding the methodology and interpretation of findings for one of the secondary measures, namely RPE
Auditory feedback improves heart rate moderation during moderate-intensity exercise
Purpose: The objective of this study is to determine whether exposure to automated HR feedback can produce improvements in the ability to regulate HR during moderate-intensity exercise and to evaluate the persistence of these improvements after feedback is removed.
Methods: Twenty healthy adults performed 10 indoor exercise sessions on cycle ergometers over 5 wk after a twice-weekly schedule. During these sessions (FB), participants received auditory feedback designed to maintain HR within a personalized, moderate-intensity training zone between 70% and 80% of estimated maximum HR. All feedback was delivered via a custom mobile software application. Participants underwent an initial assessment (PREFB) to measure their ability to maintain exercise intensity defined by the training zone without use of feedback. After completing the feedback training, participants performed three additional assessments identical to PREFB at 1 wk (POST1), 2 wk (POST2), and 4 wk (POST3) after their last feedback session. Time in zone (TIZ), defined as the ratio of the time spent within the training zone divided by the overall time of exercise, rate of perceived exertion, instrumental attitudes, and affective attitudes were then evaluated to assess results using two-way, mixed-model ANOVA with sessions and gender as factors.
Results: Training with feedback significantly improved TIZ (P G 0.01) compared with PREFB. An absence of significant differences in TIZ between FB, POST1, POST2, and POST3 (P Q 0.35) indicated that these improvements were maintained after feedback was removed. No significant differences in rate of perceived exertion (P Q 0.40) or attitude measures (P Q 0.30) were observed.
Conclusion: Auditory biofeedback is an effective mechanism for entraining HR regulation during moderate-intensity exercise in healthy adults
Study Protocol: Münster Tinnitus randomized controlled Clinical Trial-2013 based on tailor-made notched music treatment (TMNMT)
Background: Tinnitus is a result of hyper-activity/hyper-synchrony of auditory neurons coding the tinnitus frequency, which has developed to synchronous mass activity owing the lack of inhibition. We assume that removal of exactly these frequency components from an auditory stimulus will cause the brain to reorganize around tonotopic regions coding the tinnitus frequency. Based on this assumption a novel treatment for tonal tinnitus - tailor-made notched music training (TMNMT) (Proc Natl Acad Sci USA 107:1207–1210, 2010; Ann N Y Acad Sci 1252:253–258, 2012; Frontiers Syst Neurosci 6:50, 2012) has been introduced and will be tested in this clinical trial on a large number of tinnitus patients. Methods and design: A randomized controlled trial (RCT) in parallel group design will be performed in a double-blinded manner. The choice of the intervention we are going to apply is based on two “proof of concept” studies in humans (Proc Natl Acad Sci USA 107:1207–1210, 2010; Ann N Y Acad Sci 1252:253–258, 2012; Frontiers Syst Neurosci 6:50, 2012; PloS One 6(9):e24685, 2011) and on a recent animal study (Front Syst Neurosci 7:21, 2013). The RCT includes 100 participants with chronic, tonal tinnitus who listened to tailor-made notched music (TMNM) for two hours a day for three months. The effect of TMNMT is assessed by the tinnitus handicap questionnaire and visual analogue scales (VAS) measuring perceived tinnitus loudness, distress and handicap. Discussion: This is the first randomized controlled trial applying TMNMT on a larger number of patients with tonal tinnitus. Our data will verify more securely and reliably the effectiveness of this kind of completely non-invasive and low-cost treatment approach on tonal tinnitus
Reproducibility of fluorescent expression from engineered biological constructs in E. coli
We present results of the first large-scale interlaboratory study carried out in synthetic biology, as part of the 2014 and 2015 International Genetically Engineered Machine (iGEM) competitions. Participants at 88 institutions around the world measured fluorescence from three engineered constitutive constructs in E. coli. Few participants were able to measure absolute fluorescence, so data was analyzed in terms of ratios. Precision was strongly related to fluorescent strength, ranging from 1.54-fold standard deviation for the ratio between strong promoters to 5.75-fold for the ratio between the strongest and weakest promoter, and while host strain did not affect expression ratios, choice of instrument did. This result shows that high quantitative precision and reproducibility of results is possible, while at the same time indicating areas needing improved laboratory practices.Peer reviewe