38 research outputs found

    Performance of solar thermal collector using multi-walled carbon nanotubes: simulation study

    Get PDF
    A flat-plate solar collector (FPSC) using multi-walled carbon nanotubes (MWCNTs) was numerically studied. Multi-walled carbon nanotubes (MWCNTs) with outside diameters of (< 8 nm) and 0.1wt.% were utilized. A three-dimensional model was built and solved via ANSYS software and the inlet parameters as 1000 W/m2, inlet temperature of 30°C and the volume flow rates in the range of 0.2-0.8 kg/min. Using DW decreased the temperature of absorber by 0.840%, 1.437%, 1.909%, 2.308%, 2.616% and 2.869% for the varied flow rates. Relative to DW, the temperature of absorber decreased by 0.874%, 0.804%, 0.756%, 0.717%, 0.685%, 0.655% and 0.633% at the same flow rate ranges. Meanwhile, the thermal efficiency of MWCNTs nanofluid was increased by 6.080%, 6.322%, 6.311%, 6.337%, 6.450% and 6.857% for volume flow rate of 0.2-0.8 kg/min

    Energy efficiency of a flat-plate solar collector using thermally treated graphene-based nanofluids: Experimental study

    Get PDF
    © The Author(s) 2020. A covalent functionalization approach was utilized for the preparation of highly dispersed pentaethylene glycol-thermally treated graphene-water as the absorbing material inside a flat-plate solar collector. Four mass fractions of nanofluids were prepared (0.025, 0.05, 0.075, and 0.1 wt% pentaethylene glycol-thermally treated graphene-water). Graphene nanoparticles were characterized by energy dispersive X-ray analysis with a scanning electron microscope. Measurements of the thermophysical properties were subsequently carried out for the nanosuspensions. The raw investigation data were collected from an indoor flat-plate solar collector test setup. The experimental procedure included different sets of variables such as input temperatures of 303, 313, and 323 K; fluid mass flow rate of 0.00833, 0.01667, and 0.025 kg s−1; and heat flow density of 500, 750, and 1000 W m−2. The thermophysical tests of pentaethylene glycol-thermally treated graphene-water nanofluids showed a proportional increase against weight concentrations, while the specific heat power was reduced. The tests showed an increment in energy efficiency by increasing the fluid mass flow rate and heat input. By comparison, the thermal efficiency decreased with the increasing temperature of the fluid supply. Relative to the base fluid, the energy efficiency of pentaethylene glycol-thermally treated graphene/water-based flat-plate solar collector increased to 10.6%, 11%, and 13.1% at the three fluid mass flow rates. In conclusion, an exponential form was used to derive the thermal effectiveness of flat-plate solar collector based on the experimental data

    Energy efficiency of a flat-plate solar collector using thermally treated graphene-based nanofluids: Experimental study

    Get PDF
    © The Author(s) 2020. A covalent functionalization approach was utilized for the preparation of highly dispersed pentaethylene glycol-thermally treated graphene-water as the absorbing material inside a flat-plate solar collector. Four mass fractions of nanofluids were prepared (0.025, 0.05, 0.075, and 0.1 wt% pentaethylene glycol-thermally treated graphene-water). Graphene nanoparticles were characterized by energy dispersive X-ray analysis with a scanning electron microscope. Measurements of the thermophysical properties were subsequently carried out for the nanosuspensions. The raw investigation data were collected from an indoor flat-plate solar collector test setup. The experimental procedure included different sets of variables such as input temperatures of 303, 313, and 323 K; fluid mass flow rate of 0.00833, 0.01667, and 0.025 kg s−1; and heat flow density of 500, 750, and 1000 W m−2. The thermophysical tests of pentaethylene glycol-thermally treated graphene-water nanofluids showed a proportional increase against weight concentrations, while the specific heat power was reduced. The tests showed an increment in energy efficiency by increasing the fluid mass flow rate and heat input. By comparison, the thermal efficiency decreased with the increasing temperature of the fluid supply. Relative to the base fluid, the energy efficiency of pentaethylene glycol-thermally treated graphene/water-based flat-plate solar collector increased to 10.6%, 11%, and 13.1% at the three fluid mass flow rates. In conclusion, an exponential form was used to derive the thermal effectiveness of flat-plate solar collector based on the experimental data

    A numerical study of heat transfer to turbulent separation nanofluid flow in an annular passage

    Get PDF
    The separation and the reattachment of nanofluid flow through a sudden expansion in an annular passage have been studied. ANSYS FLUENT was deployed to simulate the effect of separation of nanofluid flow on the local and average convection heat transfer in an annular passage. The outer tube was made of aluminium with internal diameter of 83 mm and horizontal length of 600 mm, subjected to a constant wall heat flux. The investigation was performed with varying Reynolds number ranging from 5000 to 25000, heat flux from 719 W/m2 to 2098 W/m2, and the enhancement of step heights expanding from 0 mm (d/D=1) to 18.5 mm (d/D=1.8). The increase of flow velocity results in the sudden drop of the surface temperature in proximity to the pipe entrance, followed by gradual increment of surface temperature along the pipe. The minimum surface temperature could be obtained at flow reattachment point. The position of the minimum temperature point is independent on the inlet flow velocity. In general, the average Nusselt number increases with the increase of Reynolds number

    Graphene nanoplatelets suspended in different basefluids based solar collector: An experimental and analytical study

    Get PDF
    © 2021 by the authors. Licensee MDPI, Basel, Switzerland. A flat plate solar collector (FPSC) was analytically studied, with functionalized graphene nanoplatelets (f-GNPs) as its working fluid. Four samples (wt % nanofluids) were prepared in different base fluids such as ethylene glycol (EG), distilled water (DW):EG (70:30), and DW:EG (50:50). Experimental results (via DW) were used to verify the effectiveness of the analytical model. Some of the operating conditions were taken into account in this research, including temperatures, power, and mass flow rates. Experimental techniques were used to elucidate the modified nanofluids’ physicochemical properties, such as its particle sizes, stability, and morphology, involving electron microscopes (EMs), UV–VIS, and X-ray techniques. Differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) were applied to test the thermal analysis. The findings confirmed that the use of f-GNPs nanofluids enhanced the performance of the FPSC relative to the use of base fluids for all testing conditions. The maximum enhancement of the collector’s effectiveness at a mass flow rate of 1.5 kg min−1 and a weight concentration of 0.1 wt %, increased to 12.69%, 12.60%, and 12.62% in the case of EG, DW:EG (70:30), and DW:EG (50:50), respectively. The results also confirmed an improvement in both the heat gain (FR(τα)) and heat loss (FRUL) coefficients for the f-GNPs nanofluid

    Application of the ANOVA method in the optimization of a thermoelectric cooler-based dehumidification system

    Get PDF
    © 2022 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).In recent studies, Thermo-Electric Coolers (TEC) have been utilized for dehumidification purposes, which is mainly based on the extraction of moisture from humid atmospheric air. The reviewed literature showed that the rate of water collection from the TEC-based system can be affected by various parameters such as the module’s input voltage, the heat sink orientation, and tilt angles. In this research, the analysis of variance (ANOVA) was used to examine the significance of these factors and their interaction within the system on the TEC-based dehumidification system. Four levels were investigated for both, the Peltier’s input voltage and the rotation angle, and three levels for the tilt angle. This study indicated the significance of the studied factors and their interactions within the dehumidification system along with performing an overall numerical optimization. The experiments were conducted under the same working conditions in an enclosed environment to minimize errors. According to the overall numerical optimization, which was validated experimentally, the optimum system performance was predicted to be obtained at approximately 6.8V Peltier input volt, 65° rotation angle, and 90° tilt angles, with predicted optimum productivities of 0.32278 L/kWh and 13.03 mL/hr. For the same set of parameters, the variation between the experiment and the numerical optimization was less than 4%. The experiments show that when optimizing water collection rates for thermoelectric cooling heat sinks​ under high humidity conditions, the orientation of the heat sink should be considered.Peer reviewe

    Thermohydraulic analysis of covalent and noncovalent functionalized graphene nanoplatelets in circular tube fitted with turbulators

    Get PDF
    © The Author(s) 2022. This article is licensed under a Creative Commons Attribution 4.0 International. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.Covalent and non-covalent nanofluids were tested inside a circular tube fitted with twisted tape inserts with 45° and 90° helix angles. Reynolds number was 7000 ≤ Re ≤ 17,000, and thermophysical properties were assessed at 308 K. The physical model was solved numerically via a two-equation eddy-viscosity model (SST k-omega turbulence). GNPs-SDBS@DW and GNPs-COOH@DW nanofluids with concentrations (0.025 wt.%, 0.05 wt.% and 0.1 wt.%) were considered in this study. The twisted pipes' walls were heated under a constant temperature of 330 K. The current study considered six parameters: outlet temperature, heat transfer coefficient, average Nusselt number, friction factor, pressure loss, and performance evaluation criterion. In both cases (45° and 90° helix angles), GNPs-SDBS@DW nanofluids presented higher thermohydraulic performance than GNPs-COOH@DW and increased by increasing the mass fractions such as 1.17 for 0.025 wt.%, 1.19 for 0.05 wt.% and 1.26 for 0.1 wt.%. Meanwhile, in both cases (45° and 90° helix angles), the value of thermohydraulic performance using GNPs-COOH@DW was 1.02 for 0.025 wt.%, 1.05 for 0.05 wt.% and 1.02 for 0.1 wt.%.Peer reviewe

    Heat transfer and fluid flow over microscale backward and forward facing step: A review

    Get PDF
    Research on convective heat transfer in the microscale backward-facing step (MBFS) and microscale forward-facing step (MFFS) has been extensively conducted in the past decade. This review summarizes numerous researches on the three topics; the first section focuses on studying the effect of the geometry on the fluid flow and heat transfer behavior. The second and the third sections concentrate on the effect of the inclination angle and the flow regime on the fluid flow and heat transfer enhancement. The purpose of this article is to get a clear view and detailed summary of the influence of several parameters such as the geometrical specifications, type of fluids and boundary conditions. The enhancement in the Nusselt number is the main target of such research where correlation equations were developed in numerical and experimental studies are reported

    Heat Transfer and Hydrodynamic Properties Using Different Metal-Oxide Nanostructures in Horizontal Concentric Annular Tube: An Optimization Study

    No full text
    Numerical studies were performed to estimate the heat transfer and hydrodynamic properties of a forced convection turbulent flow using three-dimensional horizontal concentric annuli. This paper applied the standard k–ε turbulence model for the flow range 1 × 104 ≤ Re ≥ 24 × 103. A wide range of parameters like different nanomaterials (Al2O3, CuO, SiO2 and ZnO), different particle nanoshapes (spherical, cylindrical, blades, platelets and bricks), different heat flux ratio (HFR) (0, 0.5, 1 and 2) and different aspect ratios (AR) (1.5, 2, 2.5 and 3) were examined. Also, the effect of inner cylinder rotation was discussed. An experiment was conducted out using a field-emission scanning electron microscope (FE-SEM) to characterize metallic oxides in spherical morphologies. Nano-platelet particles showed the best enhancements in heat transfer properties, followed by nano-cylinders, nano-bricks, nano-blades, and nano-spheres. The maximum heat transfer enhancement was found in SiO2, followed by ZnO, CuO, and Al2O3, in that order. Meanwhile, the effect of the HFR parameter was insignificant. At Re = 24,000, the inner wall rotation enhanced the heat transfer about 47.94%, 43.03%, 42.06% and 39.79% for SiO2, ZnO, CuO and Al2O3, respectively. Moreover, the AR of 2.5 presented the higher heat transfer improvement followed by 3, 2, and 1.5

    The effect of temperature and particles concentration on the determination of thermo and physical properties of SWCNT-nanorefrigerant

    No full text
    Nanorefrigerants have the potential to enhance the heat transfer performances of refrigeration and air-conditioning systems. The current study investigates the thermophysical properties and heat transfer performance of Single Walled Carbon Nanotube (SWCNT) nanoparticles suspended in 1, 1, 1, 2-tetrafluoroethane (R-134a). Suitable models from existing studies have been used to determine the thermal conductivity and viscosity of the nanorefrigerants for the nanoparticle concentrations of (1 to 5. vol.%) at temperature of (300 to 320. K). The observation results show that, the thermal conductivity and specific heat of SWCNT/R-134a nanorefrigerant increased with the augmentation of particle concentrations and temperatures. Moreover, the results of viscosity and density of the nanorefrigerant show a significant increase with the increase of volume fractions. However, these parameters decreased accordingly with the increment of temperature. Therefore, optimal particle volume fraction is important to be considered in producing nanorefrigerants that can enhance the performance of refrigeration systems
    corecore