7 research outputs found

    Global Current Practices of Ventilatory Support Management in COVID-19 Patients: An International Survey

    Get PDF
    Background: As the global outbreak of COVID-19 continues to ravage the world, it is important to understand how frontline clinicians manage ventilatory support and the various limiting factors. / Methods: An online survey composed of 32 questions was developed and validated by an international expert panel. / Results: Overall, 502 respondents from 40 countries across six continents completed the survey. The mean number (±SD) of ICU beds was 64 ± 84. The most popular initial diagnostic tools used for treatment initiation were arterial blood gas (48%) and clinical presentation (37.5%), while the national COVID-19 guidelines were the most used (61.2%). High flow nasal cannula (HFNC) (53.8%), non-invasive ventilation (NIV) (47%), and invasive mechanical ventilation (IMV) (92%) were mostly used for mild, moderate, and severe COVID-19 cases, respectively. However, only 38.8%, 56.6% and 82.9% of the respondents had standard protocols for HFNC, NIV, and IMV, respectively. The most frequently used modes of IMV and NIV were volume control (VC) (36.1%) and continuous positive airway pressure/pressure support (CPAP/PS) (40.6%). About 54% of the respondents did not adhere to the recommended, regular ventilator check interval. The majority of the respondents (85.7%) used proning with IMV, with 48.4% using it for 12– 16 hours, and 46.2% had tried awake proning in combination with HFNC or NIV. Increased staff workload (45.02%), lack of trained staff (44.22%) and shortage of personal protective equipment (PPE) (42.63%) were the main barriers to COVID-19 management. / Conclusion: Our results show that general clinical practices involving ventilatory support were highly heterogeneous, with limited use of standard protocols and most frontline clinicians depending on isolated and varied management guidelines. We found increased staff workload, lack of trained staff and shortage of PPE to be the main limiting factors affecting global COVID-19 ventilatory support management

    On-line analysis and in situ pH monitoring of mixed acid fermentation by Escherichia coli using combined FTIR and Raman techniques

    Get PDF
    We introduce an experimental setup allowing continuous monitoring of bacterial fermentation processes by simultaneous optical density (OD) measurements, long-path FTIR headspace monitoring of CO2, acetaldehyde and ethanol, and liquid Raman spectroscopy of acetate, formate, and phosphate anions, without sampling. We discuss which spectral features are best suited for detection, and how to obtain partial pressures and concentrations by integrations and least squares fitting of spectral features. Noise equivalent detection limits are about 2.6 mM for acetate and 3.6 mM for formate at 5 min integration time, improving to 0.75 mM for acetate and 1.0 mM for formate at 1 h integration. The analytical range extends to at least 1 M with a standard deviation of percentage error of about 8%. The measurement of the anions of the phosphate buffer allows the spectroscopic, in situ determination of the pH of the bacterial suspension via a modified Henderson-Hasselbalch equation in the 6–8 pH range with an accuracy better than 0.1. The 4 m White cell FTIR measurements provide noise equivalent detection limits of 0.21 ÎŒbar for acetaldehyde and 0.26 ÎŒbar for ethanol in the gas phase, corresponding to 3.2 ÎŒM acetaldehyde and 22 ÎŒM ethanol in solution, using Henry’s law. The analytical dynamic range exceeds 1 mbar ethanol corresponding to 85 mM in solution. As an application example, the mixed acid fermentation of Escherichia coli is studied. The production of CO2, ethanol, acetaldehyde, acids such as formate and acetate, and the changes in pH are discussed in the context of the mixed acid fermentation pathways. Formate decomposition into CO2 and H2 is found to be governed by a zeroth-order kinetic rate law, showing that adding exogenous formate to a bioreactor with E. coli is expected to have no beneficial effect on the rate of formate decomposition and biohydrogen production

    Mechanical Properties and Flexural Response of Palm Shell Aggregate Lightweight Reinforced Concrete Beam

    No full text
    This work focuses on examining the mechanical characteristics and flexural response of reinforced concrete (RC) beams by incorporating oil palm shell (OPS) lightweight aggregate from oil palm shell waste. The OPS aggregates are replaced in various percentages, such as 0 to 50% of natural coarse aggregate (NCA). Mechanical properties of OPS concrete were conducted, and these properties were used to quantify the flexural performance of RC beams. Five RC beams with several gradations of OPS aggregates were cast and tested for this investigation. The first cracking, ultimate strength, load-deflection behavior, ductility index, and failure patterns of OPS aggregate beams were investigated as the corresponding behaviors to the NCA concrete beam. The fresh properties analysis demonstrated lessening the slump test by varied concentrations of OPS concrete. Furthermore, compressive strength was reduced by 44.73%, 50.83%, 53.33%, and 57.22% compared to 10%, 15%, 20%, and 50% OPC substitution at 28 days. Increasing OPS content in concrete mixes decreased splitting tensile strength, comparable to the compressive strength test. Modulus of rupture and modulus of elasticity experiments exhibited a similar trend toward reduction over the whole range of OPS concentrations (0–50%) in concrete. It was revealed that the flexural capacity of beams tends to decrease the strength with the increased proportion of OPS aggregate. Moreover, crack patterns and failure modes of beams are also emphasized in this paper for the variation of OPS replacement in the NCA. The OPS aggregate RC beam’s test results have great potential to be implemented in low-cost civil infrastructures

    Diagnostic and clinical values of non-cardiac ultrasound in COPD: A systematic review

    Get PDF
    Background Clinical and research utility of non-cardiac ultrasound (US) in chronic obstructive pulmonary disease (COPD) has been widely investigated. However, there is no systematic review assessing the clinical values of non-cardiac US techniques in COPD. Methods We systematically searched electronic databases from inception to 24 June 2020. Two independent reviewers in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines extracted data. A narrative synthesis of the results was conducted considering non-cardiac US techniques that looked for diaphragm, muscles and bones in patients with COPD. Results In total, 2573 abstracts were screened, and 94 full-text papers were reviewed. A total of 54 studies met the inclusion criteria. Thirty-five studies assessed the diaphragm, while 19 studies evaluated different muscles, including limb muscles and pulmonary lesions in COPD using US. Of the 54 included studies, 30% (16/54) evaluated the changes in either limb muscles or diaphragmatic features before and after physical interventions; 67% (36/54) assessed the correlations between sonographic features and COPD severity. Indeed, 14/15 and 9/13 studies reported a significant reduction in diaphragm excursion and thickness in COPD compared with healthy subjects, respectively; this was correlated significantly with the severity and prognosis of COPD. Three studies reported links between diaphragm length and COPD, where lower diaphragm length correlated with poorer prognosis and outcomes. Quadriceps (rectus femoris), ankle dorsiflexor (tibialis anterior) and vastus lateralis were the most common muscles in COPD assessed by US. More than 70% (12/17) of the studies reported a significant reduction in the cross-sectional area (CSA) of the rectus femoris, rectus femoris and vastus lateralis thickness in COPD compared with healthy subjects. Quadriceps CSA and thickness correlated positively with COPD prognosis, in which patients with reduced quadriceps CSA and thickness have higher risk of exacerbation, readmission and death. Conclusion US measurements of diaphragm excursion and thickness, as well as lower limb muscles strength, size and thickness, may provide a safe, portable and effective alternative to radiation-based techniques in diagnosis and prognosis as well as tracking improvement postintervention in patients with COPD

    Radiation therapy strategies for skull-base malignancies

    No full text

    SARS-CoV-2 vaccination modelling for safe surgery to save lives: data from an international prospective cohort study

    No full text
    Background: Preoperative SARS-CoV-2 vaccination could support safer elective surgery. Vaccine numbers are limited so this study aimed to inform their prioritization by modelling. Methods: The primary outcome was the number needed to vaccinate (NNV) to prevent one COVID-19-related death in 1 year. NNVs were based on postoperative SARS-CoV-2 rates and mortality in an international cohort study (surgical patients), and community SARS-CoV-2 incidence and case fatality data (general population). NNV estimates were stratified by age (18-49, 50-69, 70 or more years) and type of surgery. Best- and worst-case scenarios were used to describe uncertainty. Results: NNVs were more favourable in surgical patients than the general population. The most favourable NNVs were in patients aged 70 years or more needing cancer surgery (351; best case 196, worst case 816) or non-cancer surgery (733; best case 407, worst case 1664). Both exceeded the NNV in the general population (1840; best case 1196, worst case 3066). NNVs for surgical patients remained favourable at a range of SARS-CoV-2 incidence rates in sensitivity analysis modelling. Globally, prioritizing preoperative vaccination of patients needing elective surgery ahead of the general population could prevent an additional 58 687 (best case 115 007, worst case 20 177) COVID-19-related deaths in 1 year. Conclusion: As global roll out of SARS-CoV-2 vaccination proceeds, patients needing elective surgery should be prioritized ahead of the general population
    corecore