8 research outputs found

    Neo Left Main Channel Creation Using Double Stenting Alongside a Sapien 3 Aortic Valve Bioprosthesis for Left Main Coronary Obstruction Following Valve-in-Valve Transcatheter Aortic Valve Replacement: A Case Report With Review of Literature

    Get PDF
    Transcatheter aortic valve replacement in the setting of failed surgical bioprosthesis (valve-in-valve) is a valuable option for patients with bioprosthetic aortic stenosis or regurgitation who are deemed high risk for repeat open heart surgery. Although the procedure is successful with proper preprocedural assessment, instances of left main (LM) coronary artery ostium obstruction have been documented. We present a case of LM coronary obstruction in the immediate postoperative period following implantation of a 20-mm Edwards Sapien 3 valve inside the degenerated 21-mm Mitroflow bioprosthesis stenosis, which was treated with double stenting alongside the Edwards Sapien 3 valve creating a channel (ā€œneo left mainā€) that extended from mid-LM to the upper margin of the Edwards Sapien 3 valve. Although valve-in-valve in a Mitroflow degenerated bioprosthesis is a relatively safe procedure, 2 or more stents may be necessary to scaffold a channel to the coronary arteries between Edwards Sapien 3 prosthesis and aorta in the event of a coronary obstruction

    Adverse Cardiac Events and the Impaired Relaxation Left Ventricular Filling Pattern

    No full text
    Increasing diastolic dysfunction (DD) grade is associated with increased heart failure (HF). Patients with preserved ejection fractions and grade 1 DD may have left atrial dilatation, eā€² \u3c 8 cm/sec, increased left ventricular (LV) mass, or variable E/eā€² ratios. The aim of this study was to test the hypothesis that LV hypertrophy or E/eā€² ratio \u3e 8 may be associated with a greater incidence of HF. Methods Two hundred twelve patients with grade 1 DD and ejection fractions \u3e 50% were retrospectively studied. Group 1 comprised 108 patients with E/A ratios \u3c 0.8, without LV hypertrophy, eā€² \u3c 8 cm/sec, and E/eā€² ratios \u3c 8. Group 2 comprised 104 patients with LV hypertrophy or E/eā€² ratios \u3e 8. Patients with incident HF and valvular or coronary disease were excluded. Using two-dimensional Doppler echocardiography, LV and left atrial volumes and transmitral spectral and tissue Doppler were analyzed. Medical records were examined for laboratory data, HF admissions, and all-cause mortality from 2004 to 2012. Results Despite similar ejection fractions, patients in group 2 had greater LV and left atrial volumes, LV mass index values, and E/eā€² ratios (P \u3c .01 for all). HF incidence was greater in group 2 (30 vs 4, P \u3c .001). Combined HF or all-cause mortality was greater in group 2 (46 vs 14, P \u3c .001). Multivariate analysis revealed that HF was associated with E/eā€² ratio (P \u3c .0001), systolic blood pressure (P = .0123), and LV mass index (P = .042). Combined HF or all-cause mortality was associated with E/eā€² ratio (P \u3c .0001), LV mass index (P = .009), and lower calcium channel blocker use (P = .0011). Conclusions HF alone or HF and all-cause mortality were increased in patients with grade 1 DD in the presence of LV hypertrophy or elevated LV filling pressures

    Kounis Syndrome - an Atopic Monster for the Heart

    No full text

    Reduced Longitudinal Function in Chronic Aortic Regurgitation

    No full text
    Background: Chronic aortic regurgitation (AR) patients demonstrate left ventricular (LV) remodeling with increased LV mass and volume but may have a preserved LV ejection fraction (EF). We hypothesize that in chronic AR, global longitudinal systolic and diastolic function will be reduced despite a preserved LV EF. Methods: We studied with Doppler echocardiography 27 normal subjects, 87 patients with chronic AR with a LV EF \u3e 50% (AR + PEF), 66 patients with an EF \u3c 50% [AR + reduced LV ejection fraction (REF)] and 82 patients with hypertensive heart disease. LV volume, transmitral spectral and tissue Doppler were obtained. Myocardial velocities and their timing and longitudinal strain of the proximal and mid wall of each of the 3 apical views were obtained. Results: As compared to normals, global longitudinal strain was reduced in AR + PEF (13.8 Ā± 4.0%) and AR + REF (11.4 Ā±4.7%) vs. normals (18.4 Ā± 3.6%, both p \u3c 0.001). As an additional comparison group for AR + PEF, global longitudinal strain was reduced as compared to patients with hypertensive heart disease (p = 0.032). The average peak diastolic annular velocity (eā€™) was decreased in AR + PEF (6.9 Ā± 3.3 cm/s vs. 13.4 Ā± 2.6 cm/s, p \u3c 0.001) and AR + REF (4.8 Ā± 2.1 cm/s, p \u3c 0.001). Peak rapid filling velocity/eā€™ (E/eā€™) was increased in both AR + PEF (14.4 Ā± 6.2 vs. 6.2 Ā± 1.3, p \u3c 0.001) and AR + REF (18.8 Ā± 6.4, p \u3c0.001 vs. normals). Independent correlates of global longitudinal strain (r = 0.6416, p \u3c 0.001) included EF (p \u3c 0.0001), E/eā€™ (p \u3c 0.0001), and tricuspid regurgitation velocity (p = 0.0176). Conclusion: With chronic AR, there is impaired longitudinal function despite preserved EF. Moreover, global longitudinal strain was well correlated with noninvasive estimated LV filling pressures and pulmonary systolic arterial pressures

    Lupus Myocarditis Presenting as Life-Threatening Overt Heart Failure: A Case Report With Review of Cardiovascular Manifestations of Systemic Lupus Erythematosus

    No full text
    Systemic lupus erythematosus (SLE) is an autoimmune disease affecting multiple organ systems. Although myocardial involvement and overt myocarditis is rare, life-threatening myocarditis associated with SLE can happen. We report a case of myocarditis associated with SLE with subsequent improvement of cardiac function after immunosuppressive therapy

    Role of Speckle Tracking Echocardiography in Dilated Cardiomyopathy: A Review

    No full text
    Dilated cardiomyopathy (DCM) is an important cause of the heart failure. Timely diagnosis and optimal management decrease morbidity and mortality in heart failure patients. Although transthoracic echocardiography is used as the diagnostic test of choice in these patients, new modalities like speckle tracking echocardiography (STE) have promising results in diagnosing these patients in the earlier course of the disease. Advancements in cardiac imaging are expected as more clinical studies on the role of STE in different cardiac diseases that emerge. In this review article, we will discuss the basics of STE and its role in diagnosing DCM

    A Meta-Analysis of Mortality and Major Adverse Cardiovascular and Cerebrovascular Events in Patients Undergoing Transfemoral Versus Transapical Transcatheter Aortic Valve Implantation Using Edwards Valve for Severe Aortic Stenosis

    No full text
    The purpose of this meta-analysis was to compare 1 year mortality and major adverse cardiovascular and cerebrovascular events between transfemoral (TF) transcatheter aortic valve implantation (TAVI) and transapical (TA) TAVI performed using Edwards valves. PubMed, Embase, and the Cochrane Center Register of Controlled Trials were searched for studies published from January 2000 through March 2014. Seventeen studies met the inclusion criteria and were included in the analysis. This meta-analysis included total of 2,978 patients with severe aortic stenosis not eligible for traditional surgical procedures who underwent TF TAVI (n = 1,465) or TA TAVI (n = 1,513). End points were in-hospital, 30-day, and 1-year all-cause mortality, stroke, myocardial infarction, major bleeding, and major vascular complications. Odds ratios (ORs) with 95% confidence interval (CIs) were computed, and p values \u3c0.05 were considered to indicate statistical significance. The studies were homogenous for all outcomes except 1-year mortality. There was no significant difference between the TF and TA TAVI groups for 1-year mortality (OR 0.64, 95% CI 0.34 to 1.2, p = 0.16), incidence of stroke (OR 1.14, 95% CI 0.76 to 1.71, p = 0.52), incidence of myocardial infarction (OR 0.62, 95% CI 0.23 to 1.7, p = 0.35), and incidence of bleeding events (OR 0.76, 95% CI 0.51 to 1.14, p = 0.19). Thirty-day all-cause mortality was significantly less with TF TAVI compared with TA TAVI (OR 0.59, 95% CI 0.45 to 0.76, p \u3c0.0001). Major vascular events were significantly higher in the TF TAVI group compared with the TA TAVI group (OR 4.33, 95% CI 3.14 to 5.97, p \u3c0.00001). In conclusion, the results of this meta-analysis of 2,978 patients revealed that TA TAVI had similar 1-year major adverse cardiovascular and cerebrovascular events, fewer major vascular complications, but higher 30-day mortality compared with TF TAVI. In patients with contraindications to TF TAVI, TA TAVI is a reasonable option, although further randomized trials are warranted for evaluating long-term clinical outcomes between TF and TA TAVI
    corecore