277 research outputs found

    Artificial Extracellular Matrix Proteins Containing Phenylalanine Analogues Biosynthesized in Bacteria Using T7 Expression System and the PEGylation

    Get PDF
    In vivo incorporation of phenylalanine (Phe) analogues into an artificial extracellular matrix protein (aECM-CS5-ELF) was accomplished using a bacterial expression host that harbors the mutant phenylalanyl-tRNA synthetase (PheRS) with an enlarged binding pocket. Although the Ala294Gly/Thr251Gly mutant PheRS (PheRS**) under the control of T5 promoter allows incorporation of some Phe analogues into a protein, the T5 system is not suitable for material science studies because the amount of materials produced is not sufficient due to the moderate strength of the T5 promoter. This limitation can be overcome by using a pair of T7 promoter and T7 RNA polymerase instead. In the T7 expression system, it is difficult, however, to achieve a high incorporation level of Phe analogues, due to competition of Phe analogues for incorporation with the residual Phe that is required for synthesis of active T7 RNA polymerase. In this study, we prepared the PheRS** under T7 promoter and optimized culture condition to improve both the incorporation level of recombinant aECM protein and the incorporation level of Phe analogues. Incorporation and expression levels tend to increase in the case of p-azidophenylalanine, p-iodophenylalanine, and p-acetylphenylalanine. We evaluated the lower critical transition temperature, which is dependent on the incorporation ratio and the turbidity decreased when the incorporation level increased. Circular dichromism measurement indicated that this tendency is based on conformational change from random coil to β-turn structure. We demonstrated that polyethylene glycol (PEG) can be conjugated at reaction site of Phe analogues incorporated. We also demonstrated that the increased hydrophilicity of elastin-like sequences in the aECM-CS5-ELF made by PEG conjugation could suppress nonspecific adhesion of human umbilical vein endothelial cells (HUVEC)

    The impact of continuity correction methods in Cochrane reviews with single-zero trials with rare events: A meta-epidemiological study.

    Get PDF
    Meta-analyses examining dichotomous outcomes often include single-zero studies, where no events occur in intervention or control groups. These pose challenges, and several methods have been proposed to address them. A fixed continuity correction method has been shown to bias estimates, but it is frequently used because sometimes software (e.g., RevMan software in Cochrane reviews) uses it as a default. We aimed to empirically compare results using the continuity correction with those using alternative models that do not require correction. To this aim, we reanalyzed the original data from 885 meta-analyses in Cochrane reviews using the following methods: (i) Mantel-Haenszel model with a fixed continuity correction, (ii) random effects inverse variance model with a fixed continuity correction, (iii) Peto method (the three models available in RevMan), (iv) random effects inverse variance model with the treatment arm continuity correction, (v) Mantel-Haenszel model without correction, (vi) logistic regression, and (vii) a Bayesian random effects model with binominal likelihood. For each meta-analysis we calculated ratios of odds ratios between all methods, to assess how the choice of method may impact results. Ratios of odds ratios <0.8 or <1.25 were seen in ~30% of the existing meta-analyses when comparing results between Mantel-Haenszel model with a fixed continuity correction and either Mantel-Haenszel model without correction or logistic regression. We concluded that injudicious use of the fixed continuity correction in existing Cochrane reviews may have substantially influenced effect estimates in some cases. Future updates of RevMan should incorporate less biased statistical methods

    Establishment of the immunological self in juvenile Patiria pectinifera post-metamorphosis

    Get PDF
    Ontogeny of the immune system is a fundamental immunology issue. One indicator of immune system maturation is the establishment of the immunological self, which describes the ability of the immune system to distinguish allogeneic individuals (allorecognition ability). However, the timing of immune system maturation during invertebrate ontogeny is poorly understood. In the sea star Patiria pectinifera, cells that have dissociated from the embryos and larvae are able to reconstruct larvae. This reconstruction phenomenon is possible because of a lack of allorecognition capability in the larval immune system, which facilitates the formation of an allogeneic chimera. In this study, we revealed that the adult immune cells of P. pectinifera (coelomocytes) have allorecognition ability. Based on a hypothesis that allorecognition ability is acquired before and after metamorphosis, we conducted detailed morphological observations and survival time analysis of metamorphosis-induced chimeric larvae. The results showed that all allogeneic chimeras died within approximately two weeks to one month of reaching the juvenile stage. In these chimeras, the majority of the epidermal cell layer was lost and the mesenchymal region expanded, but cell death appeared enhanced in the digestive tract. These results indicate that the immunological self of P. pectinifera is established post-metamorphosis during the juvenile stage. This is the first study to identify the timing of immune system maturation during echinodermal ontogenesis. As well as establishing P. pectinifera as an excellent model for studies on self- and non-self-recognition, this study enhances our understanding of the ontogeny of the immune system in invertebrates

    Real-Time Time-Frequency Two-Dimensional Imaging of Ultrafast Transient Signals in Solid-State Organic Materials

    Get PDF
    In this review, we demonstrate a real-time time-frequency two-dimensional (2D) pump-probe imaging spectroscopy implemented on a single shot basis applicable to excited-state dynamics in solid-state organic and biological materials. Using this technique, we could successfully map ultrafast time-frequency 2D transient absorption signals of β-carotene in solid films with wide temporal and spectral ranges having very short accumulation time of 20 ms per unit frame. The results obtained indicate the high potential of this technique as a powerful and unique spectroscopic tool to observe ultrafast excited-state dynamics of organic and biological materials in solid-state, which undergo rapid photodegradation

    Survey of imaging dose in HDR brachytherapy

    Get PDF
    Institutional imaging protocols for the verification of brachytherapy applicator placements were investigated in a survey study of domestic radiotherapy institutions. The survey form designed by a free on-line survey system was distributed via the mailing-list system of the Japanese Society for Radiation Oncology. Survey data of 75 institutions between August 2019 and October 2019 were collected. The imaging modalities used were dependent on resources available to the institutions. The displacement of a brachytherapy applicator results in significant dosimetric impact. It is essential to verify applicator placements using imaging modalities before treatment. Various imaging modalities used in institutions included a computed tomography (CT) scanner, an angiography X-ray system, a multi-purpose X-ray system and a radiotherapy simulator. The median total exposure time in overall treatment sessions was ≤75 s for gynecological and prostate cancers. Some institutions used fluoroscopy to monitor the brachytherapy source movement. Institutional countermeasures for reducing unwanted imaging dose included minimizing the image area, changing the imaging orientation, reducing the imaging frequency and optimizing the imaging conditions. It is worth noting that half of the institutions did not confirm imaging dose regularly. This study reported on the usage of imaging modalities for brachytherapy in Japan. More caution should be applied with interstitial brachytherapy with many catheters that can lead to potentially substantial increments in imaging doses for monitoring the actual brachytherapy source using fluoroscopy. It is necessary to share imaging techniques, standardize imaging protocols and quality assurance/quality control among institutions, and imaging dose guidelines for optimization of imaging doses delivered in radiotherapy should be developed

    Development of split-force-controlled body weight support (SF-BWS) robot for gait rehabilitation

    Get PDF
    This study introduces a body-weight-support (BWS) robot actuated by two pneumatic artificial muscles (PAMs). Conventional BWS devices typically use springs or a single actuator, whereas our robot has a split force-controlled BWS (SF-BWS), in which two force-controlled actuators independently support the left and right sides of the user’s body. To reduce the experience of weight, vertical unweighting support forces are transferred directly to the user’s left and right hips through a newly designed harness with an open space around the shoulder and upper chest area to allow freedom of movement. A motion capture evaluation with three healthy participants confirmed that the proposed harness does not impede upper-body motion during laterally identical force-controlled partial BWS walking, which is quantitatively similar to natural walking. To evaluate our SF-BWS robot, we performed a force-tracking and split-force control task using different simulated load weight setups (40, 50, and 60 kg masses). The split-force control task, providing independent force references to each PAM and conducted with a 60 kg mass and a test bench, demonstrates that our SF-BWS robot is capable of shifting human body weight in the mediolateral direction. The SF-BWS robot successfully controlled the two PAMs to generate the desired vertical support forces

    ショクドウガン ジュツゴ ソウキ ニ キカン イカンロウ オ ガッペイ シタ 1レイ

    Get PDF
    The patient was a45-year-old man. He had suffered from nephrotic syndrome at time of his twenties and had steroid salvage treatment. But he retired the treatment by himself. Esophageal tumor was suspected at the screening, and he was referred to our hospital. Preoperative diagnosis was the adenocarcinoma of the esophagogastric junction(cT2N0M0 stage Ⅱ). Thoracoscopy assisted subtotal esophagectomy in prone position with D2dissection was performed. Gastric role was prepared in laparoscopic approach, and pulled up to the neck via posterior mediastinal route. Although early postoperative course was uneventful and esophageal fluoroscopy on the7th day showed no leakage, sudden dyspnea appeared on the8th day. CT examination and Bronchoscopy showed tracheoesophageal fistula. Unfortunately, the fistula didn’t get well, and we considered that it was difficult to close the fistula by only conservative treatment. Esophageal covered stent was inserted on the56th day. After that, he could start ingestion intake and was discharged from hospital on the85th day. Now, he is being followed up in our hospital
    corecore