12 research outputs found

    Effect of module design and flow patterns on performance of membrane distillation process

    Get PDF
    The present study highlights the effect of different hollow fiber membrane configurations and flow patterns on performance of membrane distillation (MD) process. The modules with helical and wavy conformations have been tested under various hydrodynamic conditions and their performance has been compared with conventional straight fiber modules. The effect of flow patterns has been studied by applying the intermittent and pulsating flows to straight hollow fiber membranes. A flux enhancement of 47% and 52% with respect to the straight fibers has been observed for helical and wavy configurations, respectively, though packing density of such modules is significantly less than their straight counterparts. For intermittent flow, an improvement of ∼30% has been recorded. The difference is more prominent at low flow rates and approaches to the straight fiber performance under steady flow at high Reynolds numbers (Re) for all hollow fiber configurations and flow patterns studied. The intermittent flow and wavy fibers exhibit an energy efficiency enhancement of ∼180% and ∼90% over their conventional counter parts, respectively. In terms of surface and volume based enhancement factor and packing density, intermittent and pulsating flow exhibited the most optimal performanc

    NullHop: A Flexible Convolutional Neural Network Accelerator Based on Sparse Representations of Feature Maps

    Get PDF
    Convolutional neural networks (CNNs) have become the dominant neural network architecture for solving many state-of-the-art (SOA) visual processing tasks. Even though Graphical Processing Units (GPUs) are most often used in training and deploying CNNs, their power efficiency is less than 10 GOp/s/W for single-frame runtime inference. We propose a flexible and efficient CNN accelerator architecture called NullHop that implements SOA CNNs useful for low-power and low-latency application scenarios. NullHop exploits the sparsity of neuron activations in CNNs to accelerate the computation and reduce memory requirements. The flexible architecture allows high utilization of available computing resources across kernel sizes ranging from 1x1 to 7x7. NullHop can process up to 128 input and 128 output feature maps per layer in a single pass. We implemented the proposed architecture on a Xilinx Zynq FPGA platform and present results showing how our implementation reduces external memory transfers and compute time in five different CNNs ranging from small ones up to the widely known large VGG16 and VGG19 CNNs. Post-synthesis simulations using Mentor Modelsim in a 28nm process with a clock frequency of 500 MHz show that the VGG19 network achieves over 450 GOp/s. By exploiting sparsity, NullHop achieves an efficiency of 368%, maintains over 98% utilization of the MAC units, and achieves a power efficiency of over 3TOp/s/W in a core area of 6.3mm2^2. As further proof of NullHop's usability, we interfaced its FPGA implementation with a neuromorphic event camera for real time interactive demonstrations

    A comparative analysis of a disposable and a reusable pedicle screw instrument kit for lumbar arthrodesis: integrating HTA and MCDA

    Get PDF
    Objective: Lumbar arthrodesis is a common surgical technique that consists of the fixation of one or more motion segments with pedicle screws and rods. However, spinal surgery using these techniques is expensive and has a significant impact on the budgets of hospitals and Healthcare Systems. While reusable and disposable instruments for laparoscopic interventions have been studied in literature, no specific information exists regarding instrument kits for lumbar arthrodesis. The aim of the present study was to perform a complete health technology assessment comparing a disposable instrument kit for lumbar arthrodesis (innovative device) with the standard reusable instrument. Methods: A prospective and observational study was implemented, by means of investigation of administrative records of patients undergoing a lumbar arthrodesis surgical procedure. The evaluation was conducted in 2013, over a 12- month time horizon, considering all the procedures carried out using the two technologies. A complete health technology assessment and a multi-criteria decision analysis approach were implemented in order to compare the two alternative technologies. Economic impact (with the implementation of an activity based costing approach), social, ethical, organisational, and technology-related aspects were taken into account. Results: Although the cost analysis produced similar results in the comparison of the two technologies (total cost equal to € 4,279.1 and € 4,242.6 for reusable instrument kit and the disposable one respectively), a significant difference between the two instrument kits was noted, in particular concerning the organisational impact and the patient safety. Conclusions: The replacement of a reusable instrument kit for lumbar arthrodesis, with a disposable one, could improve the management of this kind of devices in hospital settings

    Evaluation of thermal polarization and membrane characteristics for membrane distillation

    No full text
    Dottorato di Ricerca in Ingegneria Chimica e dei Materiali, Ciclo XXVII, 2013-2014The current PhD work emphasizes on various aspects of membrane distillation for approaching zero liquid discharge in seawater desalination. In broader sense, two themes have been discussed in detail: (i) correlation between membrane features and their performance in MD (ii) understanding and control of thermal polarization in MD. Introduction and state-of-the-art studies of MD including progress in membrane development, understanding the transport phenomenon, recent developments in module fabrication, fouling and related phenomenon and innovative applications have been discussed in introductory part of the thesis. The effect of operating conditions and dope compositions on membrane characteristics and correlation between membrane features and their performance has been discussed in subsequent section. It has been established that membrane morphology plays a crucial role in performance of the membrane for real applications. Furthermore, it has been demonstrated that the effect of membrane morphology is different for direct contact and vacuum configurations. Theoretical and experimental aspects of thermal polarization in direct contact membrane distillation have also been investigated. Thermal polarization phenomenon in a flat sheet membrane has been studied by using a specifically designed cell. The effect of operating conditions and solution concentration on thermal polarization has been explored experimentally. It has been observed that increased solution concentration favors the thermal polarization due to resulting poor hydrodynamic at the membrane surface and increase in diffusion resistance to the water vapors migrating from bulk feed phase to the membrane surface. Some active and passive techniques to decrease thermal polarization and possible fouling in membrane distillation have also been discussed in the current study. Thermal polarization can be greatly reduced by inducing secondary flows in the fluid flowing inside the fiber. The induction of secondary flows in the current study has been realized by using the fibers twisted in helical and wavy configurations. Due to improvement of thermal polarization coefficient on up and downstream, the undulating fiber geometries provide high flux and superior performance ratio. Application of intermittent and pulsatile flow to control thermal polarization in MD has also been discussed. It has been inferred that these flows have positive impact on performance ratio and volume based enhancement factors without compromising on packing density of the system. The application of MD for treatment of produced water has also been studied. The effect of membrane features on their performance for the treatment of this complex solution has been discussed. The desirable membrane features for successful application of MD for such treatment have been distinguished. It has been inferred that MD possesses the capability to produce a distillate of excellent quality and is an interesting candidate to recover the minerals present in the produced water. The fouling tendency of the membranes with different characteristics towards different types of feed solutions has also been discussed in this study. It has been shown that the porosity enhanced through the introduction of macrovoids in non-solvent induced phase separation technique creates problems related with wetting and pore scaling during practical application of such membranes. The fouling related issues are less severe in the membranes with sponge like microstructure but the overall porosity of such membranes is relatively less. Thus it has been concluded that there should be an optimum between the high throughput and stable performance of the membranes synthesized through phase inversion techniques. Conclusions of the study and future perspectives have been discussed in the last section of the study.Università degli Studi della Calabri

    3D mixed reality holograms for preoperative surgical planning of nephron-sparing surgery: evaluation of surgeons' perception

    No full text
    3D reconstructions are gaining a wide diffusion in nephron-sparing surgery (NSS) planning. They have usually been studied on common 2D flat supports, with limitations regarding real depth comprehension and interaction. Nowadays, it is possible to visualize kidney 3D reconstructions as holograms in a "mixed reality" (MR) setting. The aim of this study is to test the Face and Content Validity of this technology, and to assess the role of 3D holograms in aiding preoperative planning for highly complex renal tumors amenable by NSS

    Relationship between lumbar lordosis, pelvic parameters, PI-LL mismatch and outcome after short fusion surgery for lumbar degenerative disease. Literature review, rational and presentation of public study protocol: RELApSE study (registry for evaluation of lumbar artrodesis sagittal alignEment)

    Get PDF
    Background: Vertebral arthrodesis for degenerative pathology of the lumbar spine still remains burdened by clinical problems with significant negative results. The introduction of the sagittal balance assessment with the evaluation of the meaning of pelvic parameters and spinopelvic (PI-LL) mismatch offered new evaluation criteria for this widespread pathology, but there is a lack of consistent evidence on long-term outcome. Methods: The authors performed an extensive systematic review of literature, with the aim to identify all potentially relevant studies about the role and usefulness of the restoration or the assessment of Sagittal balance in lumbar degenerative disease. They present the study protocol RELApSE (NCT05448092 ID) and discuss the rationale through a comprehensive literature review. Results: From the 237 papers on this topic, a total of 176 articles were selected in this review. The analysis of these literature data shows sparse and variable evidence. There are no observations or guidelines about the value of lordosis restoration or PI-LL mismatch. Most of the works in the literature are retrospective, monocentric, based on small populations, and often address the topic evaluation partially. Conclusions: The RELApSE study is based on the possibility of comparing a heterogeneous population by pathology and different surgical technical options on some homogeneous clinical and anatomic-radiological measures aiming to understanding the value that global lumbar and segmental lordosis, distribution of lordosis, pelvic tilt, and PI-LL mismatch may have on clinical outcome in lumbar degenerative pathology and on the occurrence of adjacent segment disease
    corecore