623 research outputs found

    Customized Energy Down-Shift using Iridium Complexes for Enhanced Performance of Polymer Solar Cells

    Get PDF
    School of Molecular Sciences(Chemistry)For the higher performance of polymer solar cells (PSCs), many researchers tried to develop new polymers that can absorb broader range of spectrum. However, there are some limits to absorb broader range with single donor. Therefore, multi donor systems and energy transfer systems have been researched. With two different donors it is easier to enhance absorption range. As a result, multi donor and energy transfer was successful to increase performance. However, the existing systems are applying polymer-polymer systems. When two different polymers are mixed, the compatibility between two polymers is critical to morphology of blend film. Also, in polymer-polymer energy transfer, the boundary between charge transfer and energy transfer is unclear. Therefore, for the first time, we developed customized iridium (Ir(III)) complexes, with Ir(III) complex incorporated into the active materials poly(thieno[3,4-b]-thiophene/benzodithiophene) (PTB7, amorphous) or poly(3-hexylthiophene) (P3HT, high crystalline) as energy donor additives. The Ir(III) complex with the 2-phenyl quinolone ligand energy donor increased the power conversion efficiency of the corresponding devices by approximately 20%. The enhancements are attributed to the improved molecular compatibility and energy level between the Ir(III) complex and the active materials, long F??rster resonance energy transfer radius, and high energy down-shift efficiency. Overall, we reveal Ir(III) complex additives for amorphous and highly crystalline polymer active materialsthese additives would enable efficient energy transfer in polymer solar cells, while retaining the desirable active layer morphology, thereby resulting in improved light absorption and conversion.ope

    Spontaneously Migrated Tip of an Implantable Port Catheter into the Axillary Vein in a Patient with Severe Cough and the Subsequent Intervention to Reposition It

    Get PDF
    Migration of an implantable port catheter tip is one of the well-known complications of this procedure, but the etiology of this problem is not clear. We describe here a case of migration of the tip of a port catheter from the right atrium to the right axillary vein in a patient with severe cough. Coughing was suggested for this case as the cause of the catheter tip migration. We corrected the position of the catheter tip via transfemoral snaring

    Southern Hemisphere mid- and high-latitudinal AOD, CO, NO2, and HCHO: spatiotemporal patterns revealed by satellite observations

    Get PDF
    To assess air pollution emitted in Southern Hemisphere mid-latitudes and transported to Antarctica, we investigate the climatological mean and temporal trends in aerosol optical depth (AOD), carbon monoxide (CO), nitrogen dioxide (NO2), and formaldehyde (HCHO) columns using satellite observations. Generally, all these measurements exhibit sharp peaks over and near the three nearby inhabited continents: South America, Africa, and Australia. This pattern indicates the large emission effect of anthropogenic activities and biomass burning processes. High AOD is also found over the Southern Atlantic Ocean, probably because of the sea salt production driven by strong winds. Since the pristine Antarctic atmosphere can be polluted by transport of air pollutants from the mid-latitudes, we analyze the 10-day back trajectories that arrive at Antarctic ground stations in consideration of the spatial distribution of mid-latitudinal AOD, CO, NO2, and HCHO. We find that the influence of mid-latitudinal emission differs across Antarctic regions: western Antarctic regions show relatively more back trajectories from the mid-latitudes, while the eastern Antarctic regions do not show large intrusions of mid-latitudinal air masses. Finally, we estimate the long-term trends in AOD, CO, NO2, and HCHO during the past decade (2005-2016). While CO shows a significant negative trend, the others show overall positive trends. Seasonal and regional differences in trends are also discussed

    In vivo two-photon fluorescent imaging of fluoride with a desilylation-based reactive probe

    Get PDF
    A two-photon excitable molecular probe for fluoride, developed based on a fluoride-specific desilylation reaction, is demonstrated to be useful for fluorescent imaging of fluoride ions in live zebrafish by one-photon as well as two-photon microscopy for the first time.X117778Nsciescopu

    Solubility enhancement of aggregation-prone heterologous proteins by fusion expression using stress-responsive Escherichia coli protein, RpoS

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The most efficient method for enhancing solubility of recombinant proteins appears to use the fusion expression partners. Although commercial fusion partners including maltose binding protein and glutathione-<it>S</it>-transferase have shown good performance in enhancing the solubility, they cannot be used for the proprietory production of commercially value-added proteins and likely cannot serve as universal helpers to solve all protein solubility and folding issues. Thus, novel fusion partners will continue to be developed through systematic investigations including proteome mining presented in this study.</p> <p>Results</p> <p>We analyzed the <it>Escherichia coli </it>proteome response to the exogenous stress of guanidine hydrochloride using 2-dimensional gel electrophoresis and found that RpoS (RNA polymerase sigma factor) was significantly stress responsive. While under the stress condition the total number of soluble proteins decreased by about 7 %, but a 6-fold increase in the level of RpoS was observed, indicating that RpoS is a stress-induced protein. As an N-terminus fusion expression partner, RpoS increased significantly the solubility of many aggregation-prone heterologous proteins in <it>E. coli </it>cytoplasm, indicating that RpoS is a very effective solubility enhancer for the synthesis of many recombinant proteins. RpoS was also well suited for the production of a biologically active fusion mutant of <it>Pseudomonas putida </it>cutinase.</p> <p>Conclusion</p> <p>RpoS is highly effective as a strong solubility enhancer for aggregation-prone heterologous proteins when it is used as a fusion expression partner in an <it>E. coli </it>expression system. The results of these findings may, therefore, be useful in the production of other biologically active industrial enzymes, as successfully demonstrated by cutinase.</p

    Characteristics of Classified Aerosol Types in South Korea during the MAPS-Seoul Campaign

    Get PDF
    During the Megacity Air Pollution Studies-Seoul (MAPS-Seoul) campaign from May to June 2015, aerosol optical properties in Korea were obtained based on the AERONET sunphotometer measurement at five sites (Anmyon, Gangneung_WNU, Gosan_SNU, Hankuk_UFS, and Yonsei_University). Using this dataset, we examine regional aerosol types by applying a number of known aerosol classification methods. We thoroughly utilize five different methods to categorize the regional aerosol types and evaluate the results from each method by inter-comparison. The differences and similarities among the results are also discussed, contingent upon the usage of AERONET inversion products, such as the single scattering albedo. Despite several small differences, all five methods suggest the same general features in terms of the regionally dominant aerosol type: Fine-mode aerosols with highly absorbing radiative properties dominate at HankukUFS and Yonsei_University; non-absorbing fine-mode particles form a large portion of the aerosol at Gosan_SNU; and coarse-mode particles cause some effects at Anmyon. The analysis of 3-day back-trajectories is also performed to determine the relationship between classified types at each site and the regional transport pattern. In particular, the spatiotemporally short-scale transport appears to have a large influence on the local aerosol properties. As a result, we find that the domestic emission in Korea significantly contributes to the high dominance of radiation-absorbing aerosols in the Seoul metropolitan area and the air-mass transport from China largely affects the western coastal sites, such as Anmyon and Gosan_SNU

    An accurate method for quantifying and analyzing copy number variation in porcine KIT by an oligonucleotide ligation assay

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Aside from single nucleotide polymorphisms, copy number variations (CNVs) are the most important factors in susceptibility to genetic disorders because they affect expression levels of genes. In previous studies, pyrosequencing, mini-sequencing, real-time PCR, invader assays and other techniques have been used to detect CNVs. However, the higher the copy number in a genome, the more difficult it is to resolve the copies, so a more accurate method for measuring CNVs and assigning genotype is needed.</p> <p>Results</p> <p>PCR followed by a quantitative oligonucleotide ligation assay (qOLA) was developed for quantifying CNVs. The accuracy and precision of the assay were evaluated for porcine <it>KIT</it>, which was selected as a model locus. Overall, the root mean squares of bias and standard deviation of qOLA were 2.09 and 0.45, respectively. These values are less than half of those in the published pyrosequencing assay for analyzing CNV in porcine <it>KIT</it>. Using a combined method of qOLA and another pyrosequencing for quantitative analysis of <it>KIT </it>copies with spliced forms, we confirmed the segregation of <it>KIT </it>alleles in 145 F<sub>1 </sub>animals with pedigree information and verified the correct assignment of genotypes. In a diagnostic test on 100 randomly sampled commercial pigs, there was perfect agreement between the genotypes obtained by grouping observations on a scatter plot and by clustering using the nearest centroid sorting method implemented in PROC FASTCLUS of the SAS package. In a test on 159 Large White pigs, there were only two discrepancies between genotypes assigned by the two clustering methods (98.7% agreement), confirming that the quantitative ligation assay established here makes genotyping possible through the accurate measurement of high <it>KIT </it>copy numbers (>4 per diploid genome). Moreover, the assay is sensitive enough for use on DNA from hair follicles, indicating that DNA from various sources could be used.</p> <p>Conclusion</p> <p>We have established a high resolution quantification method using an oligonucleotide ligation assay to measure CNVs, and verified the reliability of genotype assignment for random animal samples using the nearest centroid sorting method. This new method will make it more practical to determine <it>KIT </it>CNV and to genotype the complicated <it>Dominant White/KIT </it>locus in pigs. This procedure could have wide applications for studying gene or segment CNVs in other species.</p
    corecore