35 research outputs found

    Demystifying speckle field interference microscopy

    Get PDF
    Dynamic speckle illumination (DSI) has recently attracted strong attention in the feld of biomedical imaging as it pushes the limits of interference microscopy (IM) in terms of phase sensitivity, and spatial and temporal resolution compared to conventional light source illumination. To date, despite conspicuous advantages, it has not been extensively implemented in the feld of phase imaging due to inadequate understanding of interference fringe formation, which is challenging to obtain in dynamic speckle illumination interference microscopy (DSI-IM). The present article provides the basic understanding of DSI through both simulation and experiments that is essential to build interference microscopy systems such as quantitative phase microscopy, digital holographic microscopy and optical coherence tomography. Using the developed understanding of DSI, we demonstrated its capabilities which enables the use of non-identical objective lenses in both arms of the interferometer and opens the fexibility to use user-defned microscope objective lens for scalable feld of view and resolution phase imaging. It is contrary to the present understanding which forces us to use identical objective lenses in conventional IM system and limits the applicability of the system for fxed objective lens. In addition, it is also demonstrated that the interference fringes are not washed out over a large range of optical path diference (OPD) between the object and the reference arm providing competitive edge over low temporal coherence light source based IM system. The theory and explanation developed here would enable wider penetration of DSI-IM for applications in biology and material sciences

    On-chip TIRF nanoscopy by applying Haar wavelet kernel analysis on intensity fluctuations induced by chip illumination

    Get PDF
    Photonic-chip based TIRF illumination has been used to demonstrate several on-chip optical nanoscopy methods. The sample is illuminated by the evanescent field generated by the electromagnetic wave modes guided inside the optical waveguide. In addition to the photokinetics of the fluorophores, the waveguide modes can be further exploited for introducing controlled intensity fluctuations for exploitation by techniques such as super-resolution optical fluctuation imaging (SOFI). However, the problem of non-uniform illumination pattern generated by the modes contribute to artifacts in the reconstructed image. To alleviate this problem, we propose to perform Haar wavelet kernel (HAWK) analysis on the original image stack prior to the application of (SOFI). HAWK produces a computational image stack with higher spatio-temporal sparsity than the original stack. In the case of multimoded non-uniform illumination patterns, HAWK processing bre aks the mode pattern while introducing spatio-temporal sparsity, thereby differentially affecting the non-uniformity of the illumination. Consequently, this assists nanoscopy methods such as SOFI to better support super-resolution, which is otherwise compromised due to spatial correlation of the mode patterns in the raw image. Furthermore, applying HAWK prior to SOFI alleviates the problem of artifacts due to non-uniform illumination without degrading temporal resolution. Our experimental results demonstrate resolution enhancement as well as reduction in artifacts through the combination of HAWK and SOFI

    Characterization of Liposomes Using Quantitative Phase Microscopy (QPM)

    Get PDF
    The rapid development of nanomedicine and drug delivery systems calls for new and effective characterization techniques that can accurately characterize both the properties and the behavior of nanosystems. Standard methods such as dynamic light scattering (DLS) and fluorescent-based assays present challenges in terms of system’s instability, machine sensitivity, and loss of tracking ability, among others. In this study, we explore some of the downsides of batch-mode analyses and fluorescent labeling, while introducing quantitative phase microscopy (QPM) as a label-free complimentary characterization technique. Liposomes were used as a model nanocarrier for their therapeutic relevance and structural versatility. A successful immobilization of liposomes in a non-dried setup allowed for static imaging conditions in an off-axis phase microscope. Image reconstruction was then performed with a phase-shifting algorithm providing high spatial resolution. Our results show the potential of QPM to localize subdiffraction-limited liposomes, estimate their size, and track their integrity over time. Moreover, QPM full-field-of-view images enable the estimation of a single-particle-based size distribution, providing an alternative to the batch mode approach. QPM thus overcomes some of the drawbacks of the conventional methods, serving as a relevant complimentary technique in the characterization of nanosystems

    Proposal of RT-PCReBased Mass Population Screening for Severe Acute Respiratory Syndrome Coronavirus 2 (Coronavirus Disease 2019)

    Get PDF
    Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) testing has lagged in many countries because of test kit shortages and analytical process bottlenecks. This study investigated the feasibility and accuracy of a sample pooling approach for wide-scale population screening for coronavirus disease 2019. A total of 940 nasopharyngeal swab samples (934 negative and 6 positive) previously tested for SARS-CoV-2 were deidentified and assigned random numbers for analysis, and 94 pools of 10 samples each were generated. Automated RNA extraction, followed by RT-PCR, was performed in a 96-well plate. Positive pools were identified, and the individual samples were reanalyzed. Of the 94 pools/wells, four were positive [Ct values: N (22.7 to 28.3), ORF1ab (23.3 to 27.2), and internal control (34.4 to 35.4)]. The 40 samples comprising the four pools were identified and reanalyzed individually; six samples were positive, with Ct values of N gene, ORF1ab, and internal control comparable to their respective wells. Additional experiments were performed on samples with high Ct values, and overall results showed 91.6% positive and 100% negative agreement compared with individual testing approach. Thus, 940 samples were tested in 148 reactions compared with 940 reactions in routine screening. The sample pooling strategy may help catch up with testing needs and minimal turnaround times and facilitate enormous savings on laboratory supplies, extraction, and PCR kits currently in short supply

    The utility of implantable loop recorders in patient management: an age- and indication-stratified study in the outpatient-implant era

    Get PDF
    INTRODUCTION: Implantable loop recorders (ILR) are now routinely implanted for long-term cardiac monitoring in the clinic setting. This study examined the real-world performance of these devices, focusing on the management decision changes made in response to ILR-recorded data. METHODS AND RESULTS: This was a single centre, prospective observational study of consecutive patients undergoing ILR implantation. All patients who underwent implantation of a Medtronic Reveal LINQ device from September 2017 to June 2019 at Barts Heart Centre were included.501 patients were included. 302 (60%) patients underwent ILR implantation for an indication of pre-syncope/syncope, 96 (19%) for palpitations, 72 (14%) for atrial fibrillation (AF) detection with a history of cryptogenic stroke and 31 (6%) for patients deemed to be high risk of serious cardiac arrhythmia.The primary outcome of this study was that an ILR-derived diagnosis altered management in 110 (22%) of patients. Secondary outcomes concerned sub-group analyses by indication: in patients who presented with syncope/presyncope, a change in management resulting from ILR data was positively associated with age (HR: 1.04 [95%CI 1.02-1.06]; p < 0.001) and negatively associated with a normal ECG at baseline (HR 0.54 [0.31-0.93]; p = 0.03). Few patients (1/57, 2%) aged < 40 years in this group underwent device implantation, compared to 19/62 patients (31%) aged 75 years and over (p = 0.0024). 22/183 (12%) of patients in the 40-74 age range had a device implanted.In patients who underwent ILR insertion following cryptogenic stroke, 13/72 patients (18%) had AF detected leading to a decision to commence anticoagulation. CONCLUSION: These results inform the utility of ILR in the clinical setting. Diagnoses provided by ILR that lead to changes in management are rare in patients under age 40, particularly following syncope, presyncope or palpitations. In older patients new diagnoses are frequently made and trigger important changes in treatment

    High-throughput spatial sensitive quantitative phase microscopy using low spatial and high temporal coherent illumination

    Get PDF
    High space-bandwidth product with high spatial phase sensitivity is indispensable for a single-shot quantitative phase microscopy (QPM) system. It opens avenue for widespread applications of QPM in the field of biomedical imaging. Temporally low coherence light sources are implemented to achieve high spatial phase sensitivity in QPM at the cost of either reduced temporal resolution or smaller field of view (FOV). In addition, such light sources have low photon degeneracy. On the contrary, high temporal coherence light sources like lasers are capable of exploiting the full FOV of the QPM systems at the expense of less spatial phase sensitivity. In the present work, we demonstrated that use of narrowband partially spatially coherent light source also called pseudo-thermal light source (PTLS) in QPM overcomes the limitations of conventional light sources. The performance of PTLS is compared with conventional light sources in terms of space bandwidth product, phase sensitivity and optical imaging quality. The capabilities of PTLS are demonstrated on both amplitude (USAF resolution chart) and phase (thin optical waveguide, height ~ 8 nm) objects. The spatial phase sensitivity of QPM using PTLS is measured to be equivalent to that for white light source and supports the FOV (18 times more) equivalent to that of laser light source. The high-speed capabilities of PTLS based QPM is demonstrated by imaging live sperm cells that is limited by the camera speed and large FOV is demonstrated by imaging histopathology human placenta tissue samples. Minimal invasive, high-throughput, spatially sensitive and single-shot QPM based on PTLS will enable wider penetration of QPM in life sciences and clinical applications

    High-Throughput Next-Generation Sequencing Respiratory Viral Panel: A Diagnostic and Epidemiologic Tool for SARS-CoV-2 and Other Viruses

    Get PDF
    Two serious public health challenges have emerged in the current COVID-19 pandemic namely, deficits in SARS-CoV-2 variant monitoring and neglect of other co-circulating respiratory viruses. Additionally, accurate assessment of the evolution, extent, and dynamics of the outbreak is required to understand the transmission of the virus. To address these challenges, we evaluated 533 samples using a high-throughput next-generation sequencing (NGS) respiratory viral panel (RVP) that includes 40 viral pathogens. The performance metrics revealed a PPA, NPA, and accuracy of 95.98%, 85.96%, and 94.4%, respectively. The clade for pangolin lineage B that contains certain distant variants, including P4715L in ORF1ab, Q57H in ORF3a, and S84L in ORF8 covarying with the D614G spike protein mutation, were the most prevalent early in the pandemic in Georgia, USA. The isolates from the same county formed paraphyletic groups, indicating virus transmission between counties. The study demonstrates the clinical and public health utility of the NGS-RVP to identify novel variants that can provide actionable information to prevent or mitigate emerging viral threats and models that provide insights into viral transmission patterns and predict transmission/resurgence of regional outbreaks as well as providing critical information on co-circulating respiratory viruses that might be independent factors contributing to the global disease burden

    Clinical validation of a multiplex PCR-based detection assay using saliva or nasopharyngeal samples for SARS-Cov-2, influenza A and B

    Get PDF
    The COVID-19 pandemic has resulted in significant diversion of human and material resources to COVID-19 diagnostics, to the extent that influenza viruses and co-infection in COVID-19 patients remains undocumented and pose serious public-health consequences. We optimized and validated a highly sensitive RT-PCR based multiplex-assay for the detection of SARS-CoV-2, influenza A and B viruses in a single-test. This study evaluated clinical specimens (n = 1411), 1019 saliva and 392 nasopharyngeal swab (NPS), tested using two-assays: FDA-EUA approved SARS-CoV-2 assay that targets N and ORF1ab gene, and the PKamp-RT-PCR based assay that targets SARS-CoV-2, influenza viruses A and B. Of the 1019 saliva samples, 17.0% (174/1019) tested positive for SARS-CoV-2 using either assay. The detection rate for SARS-CoV-2 was higher with the multiplex assay compared to SARS-specific assay [91.9% (160/174) vs. 87.9% (153/174)], respectively. Of the 392 NPS samples, 10.4% (41/392) tested positive for SARS-CoV-2 using either assay. The detection rate for SARS-CoV-2 was higher with the multiplex assay compared to SARS-specific assay [97.5% (40/41) vs. 92.1% (39/41)], respectively. This study presents clinical validation of a multiplex-PCR assay for testing SARS-CoV-2, influenza A and B viruses, using NPS and saliva samples, and demonstrates the feasibility of implementing the assay without disrupting the existing laboratory workflow

    Label-free imaging on waveguide platform with enhanced resolution and contrast

    Get PDF
    Chip-based Evanescent Light Scattering (cELS) utilizes the multiple modes of a high-index contrast optical waveguide for near-field illumination of unlabeled samples, thereby repositioning the highest spatial frequencies of the sample into the far-field. The multiple modes scattering off the sample with different phase differences is engineered to have random spatial distributions within the integration time of the camera, mitigating the coherent speckle noise. This enables label-free superior-contrast imaging of weakly scattering nanosized specimens such as extra-cellular vesicles (EVs) and liposomes, dynamics of living HeLa cells etc. We demonstrate a multi-moded straight waveguide as a partially coherent light source. For isotropic super-resolution, spatially incoherent light engineered via multiple-arms waveguide chip and intensity-fluctuation based algorithms are used. The proof-of-concept results are demonstrated on 100 nm polystyrene beads and resolution improvement of close to 2× is shown. cELS also realizes (2-10)× more contrast as opposed to conventional imaging techniques
    corecore