19 research outputs found

    Hair analysis : a review on the procedures for the determination of Trace elements and applications

    Get PDF
    Aspects related to the quality of human hair analysis are presented, such as sample collection, sample preparation, determination of trace elements and application examples. Also the hair morphology, the importance of this analysis and its uses and meanings are discussed

    Hair analysis : a review on the procedures for the determination of Trace elements and applications

    Get PDF
    Aspects related to the quality of human hair analysis are presented, such as sample collection, sample preparation, determination of trace elements and application examples. Also the hair morphology, the importance of this analysis and its uses and meanings are discussed

    Studies of the analytical potentialities of ammonium diethyl dithiophosphate in inductively coupled plasma mass spectrometry by using solid phase extraction and flow-injection analysis

    No full text
    Um sistema de injeção em fluxo envolvendo complexação com dietilditiofosfato de amônio e sorção de complexos metálicos em minicolunas de sílica gel modificada por grupos octadecil C18 é proposto para determinações multielementares em espectrometria de massa com plasma indutivamente acoplado. Influência da concentração de reagentes, natureza do ácido, tempo de reação, tempos de comutação, vazões e interferência de sódio foram investigadas. Água ou solução 2% v/v HNO3 podem ser utilizadas para lavar a coluna antes da eluição dos analitos com etanol. Amostras contendo 5000 mg Na L-1 e analisadas diretamente com o sistema proposto produzem uma concentração aparente de 63Cu de 0,45 µg L-1; por outro lado não foi observada interferência para As, Pb, Bi, Se, In, Tl, Cd, Hg e 65Cu. Para 0,25 % w/v NH4DTP e 3 mL de solução de amostra, curvas analíticas para Bi, Cu, Pb, As, Se, In, Tl, Cd, Hg no intervalo de 0,10 a 2,00 µg L-1 podem ser construídas com boas correlações (r2 > 0.998). A velocidade analítica e sensibilidade podem ser melhoradas pois dependem das condições de pré-concentração e eluição selecionadas. Com os parâmetros acima fixados, limites de detecção de 0.014 (Cu), 0.027 (As), 0.06 (Se), 0.02 (Cd), 0.029 (In), 0.043 (Hg), 0.02 (Tl), 0.06 (Pb) e 0.002 µg L-1 (Bi) foram obtidos.Complexation with ammonium diethyl dithiophosphate and sorption on a C18 bonded silica gel minicolumn in flow system was exploited for on-line separation and preconcentration in inductively coupled plasma mass spectrometry. Influence of interaction time between metallic ions and ligand, ligand concentration, nature and concentration of acid, timing, flow rates and minimization of spectral interference due to sodium were studied. Metallic complexes were stripped from the solution and retained in the minicolumn. Other ions that do not form complexes pass through the column promoting the separation of the matrix. Selectivity was improved with sequential elution. Water or 2% v/v HNO3 solution can be used for minicolumn washing before analyte elution with ethanol. When samples with sodium content up to 5000 mg L-1 were directly analysed in system, 63Cu apparent concentration of only 0.45 µg L-1 was detected while no interference were observed for As, Pb, Bi, Se, In, Tl, Cd, Hg and 65Cu. For 0.25 % of ligand solution and 3 mL sample volume in 2 % (v/v) HNO3, analytical curves for Bi, Cu, Pb, As, Se, In, Tl, Cd, Hg in the 0.10-2.00 µg L-1 range were obtained (r > 0.998). Sampling rate and detection limit depend on the selected conditions for concentration and elution. Detection limits for Cu, As, Se, Cd, In, Hg, Tl, Pb, and Bi were 0.014, 0.27, 0.06, 0.02, 0.29, 0.43, 0.02, 0.06 and 0.002 µg L-1, respectively

    Determination of trace metals in electrolytic copper by ICP OES and ICP-MS

    No full text
    The performance of axial view ICP OES and ICP-MS techniques were compared through the determination of As, Fe, Mn, Pb, Sb and Sn in electrolytic copper. Samples were prepared by two procedures: 1. Total dissolution with 5 % v/v HNO3 and 2. Dissolution with 1.4 % v/v HNO3 plus 2.0 % v/v H2SO4, followed by separation of the Cu by electrodeposition. The methods were applied for the analysis of standard copper solutions, using calibration against aqueous solutions with or without the addition of Cu. The results obtained by the two techniques were similar, but the separation of Cu from the sample matrix proved to be more adequate for practical reasons.<br>O presente trabalho apresenta um estudo comparativo das técnicas ICP-MS e ICP OES com configuração axial e também de dois métodos diferentes de tratamento das amostras, ou seja, por dissolução total com e sem separação do cobre por eletrodeposição, para as determinações de As, Fe, Mn, Pb, Sb e Sn em amostras de cobre eletrolítico. Amostras comerciais e industriais foram dissolvidas com HNO3 5% v/v e o cobre foi eletrodepositado em meio de HNO3 (1,4% v/v) e H2SO4 (2,0% v/v). Verificou-se que a separação do cobre foi eficiente, contudo se constatou contaminação de Fe e Sn durante o processo de eletrodeposição. As determinações foram realizadas utilizando-se um ICP OES Axial Varian (Vista Pro) e um ICP-MS Perkin Elmer (Elan Sciex 6000). Foi aplicada a calibração externa, com soluções padrão contendo ou não cobre na concentração equivalente à da amostra. Os limites de detecção (3s, n=10) para a técnica de ICP OES foram bastante semelhantes na presença ou não do cobre). Já usando ICP-MS, os limites foram melhores na ausência do cobre. Com o objetivo de estabelecer o nível de significância entre as técnicas de quantificação, ou seja, entre ICP OES e ICP-MS,foi aplicado o teste t emparelhado, que demonstrou, para um nível de confiança de 95%, não haver diferença significativa, tanto para as soluções sem ou com cobre. Os resultados obtidos no presente trabalho demonstraram que as técnicas ICP-MS e ICP OES fornecem resultados similares em determinadas faixas de concentração dos analitos, podendo ambas serem utilizadas, no controle de qualidade do cobre eletrolítico. Contudo, a técnica ICP-MS foi superior em termos de limite de detecção

    Emprego de nebulizador pneumático de ICP-MS como câmara de diluição em sistemas de injeção em fluxo para determinações multielementares

    No full text
    An automatic dispenser based on a flow-injection system used to introduce sample and analytical solution into an inductively coupled plasma mass spectrometer through a spray chamber is proposed. Analytical curves were constructed after the injection of 20 to 750 µL aliquots of a multielement standard solution (20.0 µg L-1 in Li, Be, Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, Se, Sr, Ag, Cd, Ba, Tl, Pb) and the acquisition of the integrated transient signals. The linear concentration range could be extended to ca. five decades. The performance of the system was checked by analyzing a NIST 1643d reference material. Accuracy could be improved by the proper selection of the injected volume. Besides good precision (r.s.d. < 2%), the results obtained with the proposed procedure were closer to the certified values of the reference material than those obtained by direct aspiration or by injecting 125 µL of several analytical solutions and samples.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES