88 research outputs found

    The effect of a Heat and Moisture Exchanger (Provox® HME) on pulmonary protection after total laryngectomy: a randomized controlled study

    Get PDF
    The goal of this randomized controlled study was to investigate the effect of Heat and Moisture Exchanger use on pulmonary symptoms and quality of life aspects in laryngectomized patients. Eighty laryngectomized patients were included and randomized into an HME and Control group. The effect of the HME was evaluated by means of Tally Sheets and Structured Questionnaires. The results showed a significant decrease in the frequency of coughing, forced expectoration, and stoma cleaning in the HME group. There were trends for the prosthetic speakers to report more fluent speech with the HME and for the HME group to report fewer sleeping problems. In conclusion, this study, performed in Poland, confirms the results of previous studies performed in other countries, showing that pulmonary symptoms decrease significantly with HME use and that related aspects such as speech and sleeping tend to improve, regardless of country or climate

    Parotid gland sparing IMRT for head and neck cancer improves xerostomia related quality of life

    Get PDF
    Background and purpose: To assess the impact of intensity modulated radiotherapy (IMRT) versus conventional radiation on late xerostomia and Quality of Life aspects in head and neck cancer patients. Patients and nethods: Questionnaires on xerostomia in rest and during meals were sent to all patients treated between January 1999 and December 2003 with a T1-4, N0-2 M0 head and neck cancer, with parotid gland sparing IMRT or conventional bilateral neck irradiation to a dose of at least 60 Gy, who were progression free and had no disseminated disease (n = 192). Overall response was 85% (n = 163); 97% in the IMRT group (n = 75) and 77% in the control group (n = 88) the median follow-up was 2.6 years. The prevalence of complaints was compared between the two groups, correcting for all relevant factors at multivariate ordinal regression analysis. Results: Patients treated with IMRT reported significantly less difficulty transporting and swallowing their food and needed less water for a dry mouth during day, night and meals. They also experienced fewer problems with speech and eating in public. Laryngeal cancer patients in general had fewer complaints than oropharynx cancer patients but both groups benefited from IMRT. Within the IMRT group the xerostomia scores were better for those patients with a mean parotid dose to the "spared" parotid below 26 Gy. Conclusion: Parotid gland sparing IMRT for head and neck cancer patients improves xerostomia related quality of life compared to conventional radiation both in rest and during meals. Laryngeal cancer patients had fewer complaints but benefited equally compared to oropharyngeal cancer patients from IMRT

    Pretreatment organ function in patients with advanced head and neck cancer: clinical outcome measures and patients' views

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Aim of this study is to thoroughly assess pretreatment organ function in advanced head and neck cancer through various clinical outcome measures and patients' views.</p> <p>Methods</p> <p>A comprehensive, multidimensional assessment was used, that included quality of life, swallowing, mouth opening, and weight changes. Fifty-five patients with stage III-IV disease were entered in this study prior to organ preserving (chemoradiation) treatment.</p> <p>Results</p> <p>All patients showed pretreatment abnormalities or problems, identified by one or more of the outcome measures. Most frequent problems concerned swallowing, pain, and weight loss. Interestingly, clinical outcome measures and patients' perception did no always concur. E.g. videofluoroscopy identified aspiration and laryngeal penetration in 18% of the patients, whereas only 7 patients (13%) perceived this as problematic; only 2 out of 7 patients with objective trismus actually perceived trismus.</p> <p>Conclusion</p> <p>The assessment identified several problems already pre-treatment, in this patient population. A thorough assessment of both clinical measures and patients' views appears to be necessary to gain insight in all (perceived) pre-existing functional and quality of life problems.</p

    Endotracheal temperature and humidity measurements in laryngectomized patients: intra- and inter-patient variability

    Get PDF
    This study assesses intra- and inter-patient variability in endotracheal climate (temperature and humidity) and effects of heat and moister exchangers (HME) in 16 laryngectomized individuals, measured repeatedly (N = 47). Inhalation Breath Length (IBL) was 1.35 s without HME and 1.05 s with HME (P < 0.0001). With HME, end-inspiratory (minimum) humidity values increased 5.8 mg H2O/L (P < 0.0001) and minimum temperature values decreased 1.6°C (P < 0.0001). For the temperature and humidity minimums, the inter-patient variability was much smaller than the short- and long-term intra-patient variability. For exhalation breath length and full breath length, the opposite was the case. Conclusions: (1) Because inter-patient variability is smaller than intra-patient variability, investigating endotracheal climate in a limited number of laryngectomized subjects is justified, provided repeated measurements per patient are accomplished; (2) main contributor to intra-patient variability is the positioning of the catheter tip in the trachea; (3) an HME leads to a shortened IBL which enhances the HME effect

    A newly developed tool for intra-tracheal temperature and humidity assessment in laryngectomized individuals: the Airway Climate Explorer (ACE)

    Get PDF
    The aim of this study is to develop a postlaryngectomy airway climate explorer (ACE) for assessment of intratracheal temperature and humidity and of influence of heat and moisture exchangers (HMEs). Engineering goals were within-device condensation prevention and fast response time characteristics. The ACE consists of a small diameter, heated air-sampling catheter connected to a heated sensor house, containing a humidity sensor. Air is sucked through the catheter by a controlled-flow pump. Validation was performed in a climate chamber using a calibrated reference sensor and in a two-flow system. Additionally, the analyser was tested in vivo. Over the clinically relevant range of humidity values (5–42 mg H2O/l air) the sensor output highly correlates with the reference sensor readings (R2 > 0.99). The 1–1/e response times are all <0.5 s. A first in vivo pilot measurement was successful. The newly developed, verified, fast-responding ACE is suitable for postlaryngectomy airway climate assessment

    Measurement of triple gauge boson couplings from W⁺W⁻ production at LEP energies up to 189 GeV

    Get PDF
    A measurement of triple gauge boson couplings is presented, based on W-pair data recorded by the OPAL detector at LEP during 1998 at a centre-of-mass energy of 189 GeV with an integrated luminosity of 183 pb⁻¹. After combining with our previous measurements at centre-of-mass energies of 161–183 GeV we obtain κ = 0.97_{-0.16}^{+0.20}, g_{1}^{z} = 0.991_{-0.057}^{+0.060} and λ = -0.110_{-0.055}^{+0.058}, where the errors include both statistical and systematic uncertainties and each coupling is determined by setting the other two couplings to their Standard Model values. These results are consistent with the Standard Model expectations

    A cost-effectiveness analysis of a preventive exercise program for patients with advanced head and neck cancer treated with concomitant chemo-radiotherapy

    Get PDF
    In recent years, concomitant chemo-radiotherapy (CCRT) has become an indispensable organ preserving treatment modality for advanced head and neck cancer, improving local control and overall survival in several anatomical sites [1]. Unfortunately, CCRT can have a detrimental effect on many functions of the upper respiratory and digestive system. Sequellae such as pain, oedema, xerostomia and fibrosis negatively affect mouth opening (trismus), chewing, swallowing and speech [1]. Several studies investigating long-term effects of CCRT have concluded that swallowing and nutritional dysfunction tend to be persistent and can be severe [2-4]. Not surprisingly, therefore, CCRT can have a negative effect on patients‟ quality of life (QoL) [2]. Moreover, even before onset of treatment patients may already present with pain, impaired swallowing, trismus, aspiration, dietary restrictions and tube dependency, and loss of body weight, because the tumour may disrupt the normal anatomy and thus interfere with normal function [1]. Many studies refer to the importance of rehabilitation after, and even during treatment, in order to support and improve those functions [2]. However, as yet, few studies have investigated the effects of (preventive) rehabilitation exercises on the predictable and inevitable swallowing and mouth opening problems for this patient group. In addition, little is known about the costs and benefits of such exercise programs for head and neck cancer. As the clinical effectiveness is established [4], it is now relevant to embark on cost-effectiveness as a contribution to decision making on coverage. The aim of this study was to analyze the incremental cost-effectiveness for a preventive exercise program (PREP) versus usual care (UC) for patients with advanced head and neck cancer treated at the Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL)

    Swallowing, nutrition and patient-rated functional outcomes at 6 months following two non-surgical treatments for T1-T3 oropharyngeal cancer

    Get PDF
    Altered fractionation radiotherapy with concomitant boost (AFRT-CB) may be considered an alternative treatment for patients not appropriate for chemoradiation (CRT). As functional outcomes following AFRT-CB have been minimally reported, this exploratory paper describes the outcomes of patients managed with AFRT-CB or CRT at 6 months post-treatment

    A Measurement of Rb using a Double Tagging Method

    Get PDF
    The fraction of Z to bbbar events in hadronic Z decays has been measured by the OPAL experiment using the data collected at LEP between 1992 and 1995. The Z to bbbar decays were tagged using displaced secondary vertices, and high momentum electrons and muons. Systematic uncertainties were reduced by measuring the b-tagging efficiency using a double tagging technique. Efficiency correlations between opposite hemispheres of an event are small, and are well understood through comparisons between real and simulated data samples. A value of Rb = 0.2178 +- 0.0011 +- 0.0013 was obtained, where the first error is statistical and the second systematic. The uncertainty on Rc, the fraction of Z to ccbar events in hadronic Z decays, is not included in the errors. The dependence on Rc is Delta(Rb)/Rb = -0.056*Delta(Rc)/Rc where Delta(Rc) is the deviation of Rc from the value 0.172 predicted by the Standard Model. The result for Rb agrees with the value of 0.2155 +- 0.0003 predicted by the Standard Model.Comment: 42 pages, LaTeX, 14 eps figures included, submitted to European Physical Journal

    Measurement of the B+ and B-0 lifetimes and search for CP(T) violation using reconstructed secondary vertices

    Get PDF
    The lifetimes of the B+ and B-0 mesons, and their ratio, have been measured in the OPAL experiment using 2.4 million hadronic Z(0) decays recorded at LEP. Z(0) --> b (b) over bar decays were tagged using displaced secondary vertices and high momentum electrons and muons. The lifetimes were then measured using well-reconstructed charged and neutral secondary vertices selected in this tagged data sample. The results aretau(B+) = 1.643 +/- 0.037 +/- 0.025 pstau(Bo) = 1.523 +/- 0.057 +/- 0.053 pstau(B+)/tau(Bo) = 1.079 +/- 0.064 +/- 0.041,where in each case the first error is statistical and the second systematic.A larger data sample of 3.1 million hadronic Z(o) decays has been used to search for CP and CPT violating effects by comparison of inclusive b and (b) over bar hadron decays, No evidence fur such effects is seen. The CP violation parameter Re(epsilon(B)) is measured to be Re(epsilon(B)) = 0.001 +/- 0.014 +/- 0.003and the fractional difference between b and (b) over bar hadron lifetimes is measured to(Delta tau/tau)(b) = tau(b hadron) - tau((b) over bar hadron)/tau(average) = -0.001 +/- 0.012 +/- 0.008
    corecore