62 research outputs found

    Hyperfunctioning Parathyroid Giant Adenoma

    Get PDF
    Purpose: The objective of this paper is to report the management and treatment of a 47-year-old patient admitted with multiple problems including asthenia, nausea and bradycardia, and was diagnosed with a giant parathyroid adenoma. Case report: A 47-year-old man was admitted to the Department of General Surgery for acute and worsening asthenia, nausea and bradycardia. Blood tests showed hypercalcemia, hypophosporemia, very high serum parathormone level, so that he was diagnosed with primary hyperparathyroidism. Cervical ultrasonography and scintigraphy with technetium 99 mTc Methoxyisobutylisonitrile (99 mTc-MIBI) showed the presence of positive nodule at the isthmus of the thyroid gland. The patient underwent neck exploration. Intra-operative iPTH essay was measured. A giant parathyroid adenoma was identified and excised, with no macroscopic signs of malignancy. Discussion and conclusion: Hyper functioning parathyroid giant adenoma can present with typical symptoms of hypercalcemic crisis: ECG alterations, kidney failure, emotional lability, confusion, delirium, psychosis, asthenia, epilepsy. Elective treatment is the excission. The surgical technique contemplates neck exploration and to ensure the finding of the adenoma, previously identified with imaging tests. It is necessary to measure intra-operative iPTH assay

    Harmonic technology versus neodymium-doped yttrium aluminium garnet laser and electrocautery for lung metastasectomy: An experimental study

    Get PDF
    We compared the efficacy of non-anatomical lung resections with that of three other techniques: monopolar electrocautery; neodymium-doped yttrium aluminium garnet laser and harmonic technology. We hypothesized that the thermal damage with harmonic technology could be reduced because of the lower temperatures generated by harmonic technology compared with that of other devices.OBJECTIVES We compared the efficacy of non-anatomical lung resections with that of three other techniques: monopolar electrocautery; neodymium-doped yttrium aluminium garnet laser and harmonic technology. We hypothesized that the thermal damage with harmonic technology could be reduced because of the lower temperatures generated by harmonic technology compared with that of other devices. METHODS Initial studies were performed in 13 isolated pig lungs for each group. A 1.5-cm capsule was inserted within the lung to mimic a tumour and a total of 25 non-anatomical resections were performed with each device. The damage of the resected lung surface and of the tumour border were evaluated according to the colour (ranging from 0 - pink colour to 4 - black colour), histological (ranging from Score 0 - no changes to Score 3 - presence of necrotic tissue) and radiological (ranging from Score 0 - isointense T2 signal at magnetic resonance imaging to Score 3 - hyperintense T2 signal) criteria. A total of seven non-anatomical resections with harmonic technology were also performed in two live pigs to assess if ex vivo results could be reproducible in live pigs with particular attention to haemostatic and air-tightness properties. RESULTS In the ex vivo lung, there was a statistical significant difference between depth of thermal damage (P < 0.0001) in electrocautery (1.3 [1.2-1.4]), laser (0.9 [0.6-0.9]) and harmonic (0.4 [0.3-0.5]) groups. Electrocautery had a higher depth of thermal damage compared with that of the laser (P = 0.01) and harmonic groups (P = 0.0005). The harmonic group had a less depth of thermal damage than that of the laser group (P = 0.01). Also, histological damages of tumour borders (P < 0.001) and resected lung surface (P < 0.001), radiological damage of tumour borders (P < 0.001) and resected lung surface (P < 0.001) and colour changes (P < 0.001) were statistically different between three study groups. Resections of in vivo pig lungs showed no bleeding; 2 of 7 cases of low air leaks were found; however, they ceased by sealing lung parenchyma with harmonic technology. CONCLUSIONS Our experimental data support the resections performed with the use of harmonic technology. The lack of severe tissue alterations could favour healing of parenchyma, assure air tightness and preserve functional lung parenchyma. However, randomized controlled studies are needed in an in vivo model to corroborate our findings

    Molecular targets and oxidative stress biomarkers in hepatocellular carcinoma: an overview

    Get PDF
    Hepatocellular carcinoma (HCC) is a complex and heterogeneous tumor with multiple genetic aberrations. Several molecular pathways involved in the regulation of proliferation and cell death are implicated in the hepatocarcinogenesis. The major etiological factors for HCC are both hepatitis B virus (HBV) and hepatitis C virus infection (HCV)
    • …
    corecore