17 research outputs found

    Differentiation between Normal and White Striped Turkey Breasts by Visible/Near Infrared Spectroscopy and Multivariate Data Analysis

    Get PDF
    The appearance of white striations over breast meat is an emerging and growing problem. The main purpose of this study was to employ the reflectance of visible-near infrared (VIS/NIR) spectroscopy to differentiate between normal and white striped turkey breasts. Accordingly, 34 turkey breast fillets were selected representing a different level of white striping (WS) defects (normal, moderate and severe). The findings of VIS/NIR were analyzed by principal component (PC1) analysis (PCA). It was found that the first PC1 for VIS, NIR and VIS/NIR region explained 98%, 97%, and 96% of the total variation, respectively. PCA showed high performance to differentiate normal meat from abnormal meat (moderate and severe WS). In conclusion, the results of this research showed that VIS/NIR spectroscopy was satisfactory to differentiate normal from severe WS turkey fillets by using several quality traits

    Predicting the quality traits of white striped turkey breast by visible/near infra-red spectroscopy and multivariate data analysis

    Get PDF
    The appearance of white striations over the breast of chicken and turkey meat is considered as a recent emerging and growing problem. The aim of this research is to investigate the ability of visible-near infra-red (VIS/NIR) spectroscopy to predict the quality traits of different levels of white striping (thickness of white striations, moderate < 1\u2009mm and severe 65 1\u2009mm) defects in turkey breast muscle. Accordingly, 36 turkey breast fillets affected by different level of white striping defects (normal, moderate and severe) were selected from 20-wk old tom turkeys. Colour traits (L*, a* and b*), pH, marinade uptake, drip loss, cooking loss, and chemical composition (moisture, fat, protein and ash) have been evaluated. Our findings showed that prediction models using partial least squares (PLS) were good for colour traits (a* for example; RPD values were 3.22 and 1.27, R2P were 0.91 and 0.57 while RER values were 11.8 and 3.12) , pH (RPD values were 5.00 and 0.01, R2P were 0.95 and 0.07 while RER values were \u20131.00 and 15.50), and chemical composition (protein content for instance, the prediction values were as the following: RPD values were 1.93 and 0.79, R2P were 0.80 and 0.34 and then RER were 8.48 and 3.80) in particular for normal and severe white striped meat respectively. In conclusion, the results of this research showed that VIS/NIR spectroscopy prediction models were satisfactory to predict the quality traits in the majority of cases

    Electronic tongue for determining the limit of detection of human pathogenic bacteria

    Get PDF
    The Electronic tongue (ET) has been used as a diagnostic technique in the medical sector. It is composed of a multisensor array set with high cross-sensitivity and low selectivity characteristics. The research investigated using Astree II Alpha MOS ET to determine the limit of early detection and diagnosis of food-borne human pathogenic bacteria and to recognize unknown bacterial samples relying on pre-stored models. Staphylococcus aureus (ATCC 25923) and Escherichia coli (ATCC25922) were proliferated in nutrient broth (NB) medium with original inoculum (approximately 107*105 CFU/mL). They were diluted up to 10-14 and the dilutions ranging from 10-14 to 10-4 were measured using ET. The partial least square (PLS) regression model detected the limit of detection (LOD) of the concentration that was monitored to grow the bacteria with different incubation periods (from 4 to 24 h). The measured data were analysed by principal component analysis (PCA) and followed by projecting unknown bacterial samples (at specific concentrations and time of incubation) to examine the recognition ability of the ET. Astree II ET was able to track bacterial proliferation and metabolic changes in the media at very low concentrations (between the dilutions 10-11 and 10-10 for both bacteria). S.aureus was detected after 6 h incubation period and between 6 and 8 h for E.coli. After creating the strains’ models, ET was also able to classify unknown samples according to their foot-printing characteristics in the media (S.aureus, E.coli or neither of them). The results considered ET a powerful potentiometric tool for the early identification of food-borne microorganisms in their native state within a complex system to save patients’ lives

    Following drug degradation and consequent taste deterioration of an oral reconstituted paediatric suspension during dosing interval via electronic tongue

    Get PDF
    BackgroundThe taste of oral liquid dosage forms is a crucial factor that impacts pediatric patient compliance. Taste of suspensions can be typically evaluated by human volunteers. Recently, the electronic tongue (ET) has been proven as an emerging tool that could be useful to follow up various formulations’ properties like taste and composition. This study aimed to evaluate the potential use of ET in assessing the taste deterioration of reconstituted oral suspensions and compare the results obtained with the typical in vivo panel taste method. MethodsFour commercially available brands of amoxicillin/ clavulanic acid suspensions (one brand and three generic formulations) were reconstituted and stored in refrigerator to assess their taste on a daily basis. The taste of these products was assessed using Alpha-Astree ET and the obtained results were compared with those obtained from an in vivo panel taste assessment using a hedonic panel test (the 5-point hedonic scale). ResultsAll evaluated suspensions exhibited similar trends. ET and in vivo analysis indicated low taste scores for all evaluated suspensions immediately after reconstitution, possibly due to the incomplete dissolution of sucrose. The scores for all formulations were higher on day 2, followed by a steady state for the next two days. After that, a significant decay in the scores was observed in the fifth day for all evaluated suspensions. ET results were in excellent agreement with the results obtained via in vivo panel test method. ConclusionThe ET seems to be promising for testing the taste of pharmaceutical liquid preparations and evaluate possible deterioration upon storage or after reconstitution. It may provide a platform to avoid the involvement of pediatric volunteers in clinical evaluation and can be employed as a quality control tool during manufacturing

    Classification of Mixtures of Odorants from Livestock Buildings by a Sensor Array (an Electronic Tongue)

    No full text
    An electronic tongue comprising different numbers of electrodes was able to classify test mixtures of key odorants characteristic of bioscrubbers of livestock buildings (n-butyrate, iso-valerate, phenolate, p-cresolate, skatole and ammonium). The classification of model solutions indicates that the electronic tongue has a promising potential as an on- line sensor for characterization of odorants in livestock buildings. Back propagation artificial neural network was used for classification. The average classification rate was above 80% in all cases. A limited, but sufficient number of electrodes were selected by average classification rate and relative entropy. The sufficient number of electrodes decreased standard deviation and relative standard deviation compared to the full electrode array

    Calibration of a Sensor Array (an Electronic Tongue) for Identification and Quantification of Odorants from Livestock Buildings

    No full text
    This contribution serves a dual purpose. The first purpose was to investigate the possibility of using a sensor array (an electronic tongue) for on-line identification and quantification of key odorants representing a variety of chemical groups at two different acidities, pH 6 and 8. The second purpose was to simplify the electronic tongue by decreasing the number of electrodes from 14, which was the number of electrodes in the prototype. Different electrodes were used for identification and quantification of different key odorants. A total of eight electrodes were sufficient for identification and quantification in micromolar concentrations of the key odorants n-butyrate, ammonium and phenolate in test mixtures also containing iso-valerate, skatole and p-cresolate. The limited number of electrodes decreased the standard deviation and the relative standard deviation of triplicate measurements in comparison with the array comprising 14 electrodes. The electronic tongue was calibrated using 4 different test mixtures, each comprising 50 different combinations of key odorants in triplicates, a total of 600 measurements. Back propagation artificial neural network, partial least square and principal component analysis were used in the data analysis. The results indicate that the electronic tongue has a promising potential as an on- line sensor for odorants absorbed in the bioscrubber used in livestock buildings

    Identification and Quantification of Olive Oil Quality Parameters Using an Electronic Nose

    No full text
    An electronic nose (EN), which is a kind of chemical sensors, was employed to check olive oil quality parameters. Fifty samples of olive oil, covering the four quality categories extra virgin, virgin, ordinary virgin and lampante, were gathered from different Palestinian cities. The samples were analysed chemically using routine tests and signals for each chemical were obtained using EN. Each signal acquisition represents the concentration of certain chemical constituents. Partial least squares (PLS) models were used to analyse both chemical and EN data. The results demonstrate that the EN was capable of modelling the acidity parameter with a good performance. The correlation coefficients of the PLS-1 model for acidity were 0.87 and 0.88 for calibration and validation sets, respectively. Furthermore, the values of the standard error of performance to standard deviation (RPD) for acidity were 2.61 and 2.68 for the calibration and the validation sets, respectively. It was found that two principal components (PCs) in the PLS-1 scores plot model explained 86% and 5% of EN and acidity variance, respectively. PLS-1 scores plot showed a high performance in classifying olive oil samples according to quality categories. The results demonstrated that EN can predict/model acidity with good precision. Additionally, EN was able to discriminate between diverse olive oil quality categories

    The Taste of Commercially Available Clarithromycin Oral Pharmaceutical Suspensions in the Palestinian Market: Electronic Tongue and In Vivo Evaluation

    No full text
    Background: The taste of oral liquid dosage forms is a crucial factor that impacts paediatric patient compliance. The electronic tongue (ET) is an emerging tool that could be useful in taste assessment in order to minimize the involvement of humans in such evaluations. Purpose: The aim of this study is to evaluate the taste of commercially available clarithromycin (CM) oral pharmaceutical suspensions in the Palestinian market. Method: Commercially available CM suspensions (the brand Klacid® and two generic K1 and K2) were assayed using the high performance liquid chromatography (HPLC) method. Then, the taste of these products was assessed using alpha-astree ET. In addition, an in vivo taste assessment was conducted on paediatric patients by a hedonic panel test. Moreover, volunteering community pharmacists were asked to rank the taste of these three products according to their experience from the best to the worst. Results: All suspension products had a CM concentration not less than 98% of the label amount. The ET results coupled with the principal component analysis (PCA) showed a very clear discrimination of the samples with different distances between groups (p-values < 0.001). Suspensions were in the following order in terms of taste: Klacid® > K1 > K2. Moreover, The pattern discrimination index between (K1 and Klacid®), (K1 and K2) and (Klacid® and K2) were 8.81%, 65.75%, and71.94%, respectively which suggests that K1 and Klacid® are the most similar preparations in terms of taste. Interestingly, these results were in excellent agreement with the pharmacist ranking and patient acceptance test. Conclusions: The evaluated preparations showed significantly different taste within the order of Klacid® > K1 > K2, as suggested by both the ET and in vivo results. Moreover, our results confirm the capability of alpha-astree ET in the taste assessment of oral suspensions and in predicting volunteer responses, which highlights its beneficial use as an in vitro taste assessment tool and as an alternative to human-based taste evaluations

    Non-Destructive Quality Measurement for Three Varieties of Tomato Using VIS/NIR Spectroscopy

    No full text
    The non-destructive visible/near-infrared (VIS/NIR) spectroscopy is a promising technique in determining the quality of agricultural commodities. Therefore, this study aimed to examine the ability of VIS/NIR spectroscopy (550–1100 nm) to distinguish between three different varieties of tomato (i.e., Ekram, Harver and Izmer), as well as to predict the quality parameters of tomato, such as soluble solids content (SSC), titratable acidity (TA), taste (SSC/TA) and firmness. Ninety intact samples from three tomato varieties were used. These samples were examined using VIS/NIR spectroscopy and quality parameters were also measured using traditional methods. Principal component analysis (PCA) and partial least square (PLS) were carried out. The results of PCA showed the ability of VIS/NIR spectroscopy to distinguish between the three varieties, where two PCs explained about 99% of the total variance in both calibration and validation sets. Moreover, PLS showed the possibility of modelling quality parameters. The correlation coefficient (R2) and the ratio of performance deviation (RPD) for all quality parameters (except for firmness) were found to be higher than 0.85 and 2.5, respectively. Thus, these results indicate that the VIS/NIR spectroscopy can be used to discriminate between different varieties of tomato and predict their quality parameters
    corecore