337 research outputs found

    Drone-Based Vegetation Assessment in Arid Ecosystems

    Get PDF
    Proof of long-term vegetation change in arid rangelands is often insufficient to influence policy, even when the change is clear to ecologists. Drones provide a way to collect unbiased evidence of plant spatiotemporal distribution at a dramatically reduced cost for the scales needed in these habitats. Assessment of phytomass spatial distribution by drone has become a routine, but further analysis requires advanced skills in data collection and post-flight processing. Accurate assessment of phytomass temporal change will require protocols to be developed for data collection and analysis. Biodiversity assessment by drone is unreliable, but there is potential for assessing phytomass change within and among taxonomic groups in arid rangelands, by repeatedly sampling areas in which perennial plants have been classified manually

    Seismic risk in the city of Al Hoceima (north of Morocco) using the vulnerability index method, applied in Risk-UE project

    Get PDF
    The final publication is available at Springer via http://dx.doi.org/10.1007/s11069-016-2566-8Al Hoceima is one of the most seismic active regions in north of Morocco. It is demonstrated by the large seismic episodes reported in seismic catalogs and research studies. However, seismic risk is relatively high due to vulnerable buildings that are either old or don’t respect seismic standards. Our aim is to present a study about seismic risk and seismic scenarios for the city of Al Hoceima. The seismic vulnerability of the existing residential buildings was evaluated using the vulnerability index method (Risk-UE). It was chosen to be adapted and applied to the Moroccan constructions for its practicality and simple methodology. A visual inspection of 1102 buildings was carried out to assess the vulnerability factors. As for seismic hazard, it was evaluated in terms of macroseismic intensity for two scenarios (a deterministic and probabilistic scenario). The maps of seismic risk are represented by direct damage on buildings, damage to population and economic cost. According to the results, the main vulnerability index of the city is equal to 0.49 and the seismic risk is estimated as Slight (main damage grade equal to 0.9 for the deterministic scenario and 0.7 for the probabilistic scenario). However, Moderate to heavy damage is expected in areas located in the newer extensions, in both the east and west of the city. Important economic losses and damage to the population are expected in these areas as well. The maps elaborated can be a potential guide to the decision making in the field of seismic risk prevention and mitigation strategies in Al Hoceima.Peer ReviewedPostprint (author's final draft

    Developed performance of rGO/p-Si Schottky junction solar cells

    Get PDF
    Graphene in combination with Si has been extensively used to prepare efficient and stable p-graphene/n-Si Schottky junction solar cells. In contrast, there is a difficulty in including graphene within the fabrication process of efficient and stable n-graphene/p-Si Schottky junction solar cells. The reason for this is that there is a challenge in achieving an effective and stable n-doping process for graphene or rGO due to the ambient environment. In this work, a novel approach is introduced for preparing more efficient, stable, larger and simpler n-rGO/p-Si Schottky junction solar cells. The n-rGO rather than graphene, which has been successfully developed using NH3 molecules, is included in the fabrication process of n-rGO/p-Si Schottky junction solar cells. Accordingly, the power conversion efficiency of 9.7 was obtained for prepared devices after applying ammonia treatment for 3 h. For the first time, the developed n-rGO layers are also excellently employed to prepare large n-rGO/p-Si Schottky junction solar cells with ideal J-V curves. The improved efficiency of 12.6 % is reached for n-rGO/p-Si Schottky junction solar cells prepared with an active area of 0.6 cm2. To improve the stability, devices are coated with PMMA as an encapsulated layer, leading to an improvement in the stability for 2 months in the ambient air. Additionally, a recorded efficiency of 13.8 % is achieved. We attribute this development to the chemisorption of ammonia molecules on rGO, which effectively develops the performance of devices

    Thermal and flow performance analysis of a concentrated linear Fresnel solar collector with transverse ribs

    Get PDF
    Data availability statement: The original contributions presented in the study are included in the article/Supplementary Material; further inquiries can be directed to the corresponding authors.Copyright © 2023 Hasan, Sherza, Abed, Togun, Ben Khedher, Sopian, Mahdi and Talebizadehsardari. This article deals with the impact of including transverse ribs within the absorber tube of the concentrated linear Fresnel collector (CLFRC) system with a secondary compound parabolic collector (CPC) on thermal and flow performance coefficients. The enhancement rates of heat transfer due to varying governing parameters were compared and analyzed parametrically at Reynolds numbers in the range 5,000–13,000, employing water as the heat transfer fluid. Simulations were performed to solve the governing equations using the finite volume method (FVM) under various boundary conditions. For all Reynolds numbers, the average Nusselt number in the circular tube in the CLFRC system with ribs was found to be larger than that of the plain absorber tube. Also, the inclusion of transverse ribs inside the absorber tube increases the average Nusselt number by approximately 115% at Re = 5,000 and 175% at Re = 13,000. For all Reynolds numbers, the skin friction coefficient of the circular tube with ribs in the CLFRC system is larger than that of the plain absorber tube. The coefficient of surface friction reduces as the Reynolds number increases. The performance assessment criterion was found to vary between 1.8 and 1.9 as the Reynolds number increases

    Thermal analysis of horizontal earth-air heat exchangers in a subtropical climate: An experimental study

    Get PDF
    The earth-air heat exchanger (EHX) has a promising potential to passively save the energy consumption of traditional air conditioning systems while maintaining a high degree of indoor comfort. The use of EHX systems for air conditioning in commercial and industrial settings offers several environmental benefits and is capable of operating in both standalone and hybrid modes. This study tests the performance and effectiveness of an EHX design in a sandy soil area in Baghdad, Iraq. The area has a climate of the subtropical semi-humid type. Ambient air temperatures and soil temperatures were recorded throughout the months of 2021. During the months of January and June, the temperatures of the inlet and outflow air at varying air velocities were monitored concurrently in 10-min increments at each location. Further numerical and thermodynamical analyses of the measurements were conducted to reveal the influencing performance parameters. The highest temperature rises of air between the input and exit sections were determined as 12.3°C (January) and 17.2°C (June). It is found that the maximum values of effectiveness are 0.80 and 0.81, while coefficients of performance are 1.6 and 1.8 for January and June, respectively. It is also found that the EHX shows good functionality and effectiveness, with potential energy savings for equipment for cooling and heating under different weather conditions

    Improving the melting performance in a triple-pipe latent heat storage system using hemispherical and quarter-spherical fins with a staggered arrangement

    Get PDF
    Data availability statement: The original contributions presented in the study are included in the article/Supplementary Material; further inquiries can be directed to the corresponding author.This study aims to evaluate the melting characteristics of a phase change material (PCM) in a latent heat storage system equipped with hemispherical and quarter-spherical fins. A vertical triple-pipe heat exchanger is used as the PCM-based heat storage unit to improve the melting performance compared with a double-pipe system. Furthermore, the fins are arranged in inline and staggered configurations to improve heat transfer performance. For the quarter-spherical fins, both upward and downward directions are examined. The results of the system equipped with novel fins are compared with those without fins. Moreover, a fin is added to the heat exchanger’s base to compensate for the natural convection effect at the bottom of the heat exchanger. Considering similar fin volumes, the results show that the system equipped with four hemispherical fins on the side walls and an added fin on the bottom wall has the best performance compared with the other cases with hemispherical fins. The staggered arrangement of the fins results in a higher heat transfer rate. The downward quarter-spherical fins with a staggered configuration show the highest performance among all the studied cases. Compared with the case without fins, the heat storage rate improves by almost 78% (from 35.6 to 63.5 W), reducing the melting time by 45%.King Khalid University Deanship of Scientific Research Large Groups [Project under grant number (RGP. 2/142/43)]; Brunel University London

    Assessment of urban green space dynamics influencing the surface urban heat stress using advanced geospatial techniques

    Get PDF
    Urban areas are mostly heterogeneous due to settlements and vegetation including forests, water bodies and many other land use and land cover (LULC) classes. Due to the overwhelming population pressure, urbanization, industrial works and transportation systems, urban areas have been suffering from a deficiency of green spaces, which leads to an increase in the variation of temperature in urban areas. This study investigates the conceptual framework design towards urban green space (UGS) and thermal variability over Kolkata and Howrah city using advanced remote sensing (RS) and geospatial methods. The low green space is located in the highly built-up area, which is influenced by thermal variations. Therefore, the heat stress index showed a high area located within the central, north, northwestern and some parts of the southern areas. The vegetated areas decreased by 8.62% during the ten years studied and the other land uses increased by 11.23%. The relationship between land surface temperature (LST) and the normalized difference vegetation index (NDVI) showed significant changes with R2 values between 0.48 (2010) and 0.23 (2020), respectively. The correlation among the LST and the normalized difference built-up index (NDBI) showed a notable level of change with R2 values between 0.38 (2010) and 0.61 (2020), respectively. The results are expected to contribute significantly towards urban development and planning, policymaking and support for key stakeholders responsible for the sustainable urban planning procedures and processes

    Theoretical study of Oldroyd-b visco-elastic fluid flow through curved pipes with slip effects in polymer flow processing

    Get PDF
    The characteristics of the flow field of both viscous and viscoelastic fluids passing through a curved pipe with a Navier slip boundary condition have been investigated analytically in the present study. The Oldroyd-B constitutive equation is employed to simulate realistic transport of dilute polymeric solutions in curved channels. In order to linearize the momentum and constitutive equations, a perturbation method is used in which the ratio of radius of cross section to the radius of channel curvature is employed as the perturbation parameter. The intensity of secondary and main flows is mainly affected by the hoop stress and it is demonstrated in the present study that both the Weissenberg number (the ratio of elastic force to viscous force) and slip coefficient play major roles in determining the strengths of both flows. It is also shown that as a result of an increment in slip coefficient, the position of maximum velocity markedly migrates away from the pipe center towards the outer side of curvature. Furthermore, results corresponding to Navier slip scenarios exhibit non-uniform distributions in both the main and lateral components of velocity near the wall which can notably vary from the inner side of curvature to the outer side. The present solution is also important in polymeric flow processing systems because of experimental evidence indicating that the no-slip condition can fail for these flows, which is of relevance to chemical engineers
    corecore