273 research outputs found

    Preoperative factors predictive of postoperative decimal visual acuity ≥ 1.0 following surgical treatment for idiopathic epiretinal membrane

    Get PDF
    Hiroshi Kunikata1, Toshiaki Abe2, Jiro Kinukawa1, Kohji Nishida1,31Department of Ophthalmology and Visual Science, Tohoku University Graduate School of Medicine, Sendai, Japan; 2Division of Clinical Cell Therapy, Tohoku University Graduate School of Medicine, Sendai, Japan; 3Department of Ophthalmology, Osaka University Medical School, Suita, JapanPurpose: To report the preoperative best-corrected visual acuity (BCVA) and foveal thickness (FT) values that lead to a postoperative decimal BCVA of ≥ 1.0 after surgical removal of an idiopathic epiretinal membrane (ERM).Methods: This is a retrospective case series of 73 eyes that underwent surgery for removal of an idiopathic ERM. All eyes had been treated by a single surgeon using a 25-gauge transconjunctival sutureless vitrectomy and indocyanine green-assisted internal limiting membrane peel. The BCVA and FT were measured at baseline and 6 months postoperatively.Results: A postoperative decimal BCVA ≥ 1.0 was obtained in eyes with a preoperative decimal BCVA ≥ 0.3 but not in those with a preoperative decimal BCVA ≤ 0.2. The incidence of obtaining a postoperative decimal BCVA ≥ 1.0 was significantly (P = 0.002) higher in eyes with a preoperative decimal BCVA ≥ 0.5 (50%) than in eyes with a preoperative decimal BCVA < 0.5 (11%). Additionally, a postoperative decimal BCVA of ≥ 1.0 was obtained in 51% of the eyes that had a preoperative FT < 400 µm, compared with only 21% of eyes with a preoperative FT ≥ 400 µm (P = 0.01). The incidence of obtaining a postoperative decimal BCVA ≥ 1.0 was significantly higher in eyes with preoperative decimal BCVA ≥ 0.5 and FT < 400 µm (60%) than in eyes with preoperative decimal BCVA ≥ 0.5 and FT ≥ 400 µm (20%; P = 0.03 ) or preoperative BCVA < 0.5 and FT ≥ 400 µm (7%; P < 0.001).Conclusions: These findings indicate that eyes with both preoperative BCVA ≥ 0.5 and FT < 400 µm have a significantly better chance of obtaining a postoperative decimal BCVA ≥ 1.0 following idiopathic ERM removal.Keywords: 25-gauge vitrectomy, optical coherence tomography, epimacular membrane, epiretinal membrane, visual acuity, foveal thicknes

    Detect Gluon Polarisation at BNL-RHIC Through J/\psi Pair Production Process

    Get PDF
    Our recent study shows that the double spin asymmetry of J/\psi pair production is measurable in polarised p-p collision at RHIC in near future. And hence it enables us to extract the polarised gluon distribution function \Delta G (x).Comment: Contribution to ICHEP, July 24 - 27, 2002. Amsterdam, the Netherland

    The spin correlation in top quark production: QCD corrections vs anomalous couplings

    Get PDF
    We discuss top quark production and its subsequent decay at lepton colliders including both QCD corrections and anomalous gamma / Z - t t-bar couplings. The off-diagonal spin basis for the top and anti-top quarks is shown to be useful to probe the anomalous couplings.Comment: 6 pages, LaTeX, 8 postscript figures, uses espcrc2.sty; talk presented at Loops and Legs in Quantum Field Theory, April 2000, Bastei, German

    QCD Corrections to the nucleon's spin structure function G2(x,Q2)G_2(x,Q^2)

    Get PDF
    We investigate the renormalization of the twist-3 operators which are relevant for the spin-dependent structure function g2(x,Q2)g_{2}(x, Q^{2}). We derive the anomalous dimension for the non-singlet part by calculating the off-shell Green's functions of the twist-3 operators including the operators which are proportional to the equation of motion.Comment: 10 pages, LaTeX, 1 Postscript figur

    Potential and action mechanism of favipiravir as an antiviral against Junin virus

    Get PDF
    Favipiravir is a nucleoside analogue that inhibits the replication and transcription of a broad spectrum of RNA viruses, including pathogenic arenaviruses. In this study, we isolated a favipiravir-resistant mutant of Junin virus (JUNV), which is the causative agent of Argentine hemorrhagic fever, and analyzed the antiviral mechanism of favipiravir against JUNV. Two amino acid substitutions, N462D in the RNA-dependent RNA polymerase (RdRp) and A168T in the glycoprotein precursor GPC, were identified in the mutant. GPC-A168T substitution enhanced the efficiency of JUNV internalization, which explains the robust replication kinetics of the mutant in the virus growth analysis. Although RdRp-N462D substitution did not affect polymerase activity levels in a minigenome system, comparisons of RdRp error frequencies showed that the virus with RdRp-D462 possessed a significantly higher fidelity. Our next generation sequence (NGS) analysis showed a gradual accumulation of both mutations as we passaged the virus in presence of favipiravir. We also provided experimental evidence for the first time that favipiravir inhibited JUNV through the accumulation of transition mutations, confirming its role as a purine analogue against arenaviruses. Moreover, we showed that treatment with a combination of favipiravir and either ribavirin or remdesivir inhibited JUNV replication in a synergistic manner, blocking the generation of the drug-resistant mutant. Our findings provide new insights for the clinical management and treatment of Argentine hemorrhagic fever

    Development and evaluation of a rapid and simple diagnostic assay for COVID-19 based on loop-mediated isothermal amplification

    Get PDF
    Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a highly pathogenic novel coronavirus that has caused a worldwide outbreak.Here we describe a reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay that uses a portable device for efficient detection of SARS-CoV-2. This RT-LAMP assay specifically detected SARS-CoV-2 without cross-reacting with the most closely related human coronavirus, SARS-CoV. Clinical evaluation of nasal swab samples from suspected SARS-CoV-2 pneumonia (COVID-19) patients showed that the assay could detect over 23.7 copies within 15 min with a 100% probability. Since the RT-LAMP assay can be performed with a portable battery-supported device, it is a rapid, simple, and sensitive diagnostic assay for COVID-19 that can be available at point-of-care. We also developed the RT-LAMP assay without the RNA extraction step-Direct RT-LAMP, which could detect more than 1.43 x 103 copies within 15 min with a 100% probability in clinical evaluation test. Although the Direct RT-LAMP assay was less sensitive than the standard RT-LAMP, the Direct RT-LAMP assay can be available as the rapid first screening of COVID-19 in poorly equipped areas, such as rural areas in developing countries

    Small Cell Carcinoma of the Ureter with Malignant Lymphoma: Case Report and Literature Review

    Get PDF
    A 78-year-old man was referred to our hospital for gross hematuria. Ultrasonography and magnetic resonance urography revealed tumor in the right lower ureter. Computed tomography revealed right cervical lymph node swelling and pathological diagnosis was diffuse large B-cell lymphoma. Right nephroureterectomy was performed and pathologic examination revealed small cell carcinoma of the ureter with a small urothelial cell carcinoma component. As the patient had concomitant other malignancies, additional systemic chemotherapy was not performed. As of 3 months after operation, postoperative course has been uneventful. Only 11 cases of primary small cell carcinoma of the ureter have been described
    corecore